The optimization on flow scheme of helium liquefier with genetic algorithm

被引:8
作者
Wang, H. R. [2 ,3 ]
Xiong, L. Y. [1 ,2 ]
Peng, N. [1 ,2 ]
Liu, L. Q. [1 ,2 ]
机构
[1] State Key Lab Technol Space Cryogen Propellants, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Key Lab Cryogen, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100190, Peoples R China
关键词
Helium liquefaction; Optimization; Flow scheme; Genetic algorithm;
D O I
10.1016/j.cryogenics.2016.12.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
There are several ways to organize the flow scheme of the helium liquefiers, such as arranging the expanders in parallel (reverse Brayton stage) or in series (modified Brayton stages). In this paper, the inlet mass flow and temperatures of expanders in Collins cycle are optimized using genetic algorithm (GA). Results show that maximum liquefaction rate can be obtained when the system is working at the optimal parameters. However, the reliability of the system is not well due to high wheel speed of the first turbine. Study shows that the scheme in which expanders are arranged in series with heat exchangers between them has higher operation reliability but lower plant efficiency when Working at the same situation. Considering both liquefaction rate and system stability, another flow scheme is put forward hoping to solve the dilemma. The three configurations are compared from different aspects, they are respectively economic cost, heat exchanger size, system reliability and exergy efficiency. In addition, the effect of heat capacity ratio on heat transfer efficiency is discussed. A conclusion of choosing liquefier configuration is given in the end, which is meaningful for the optimal design of helium liquefier. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 6 条
[1]   Thermodynamic analysis of Collins helium liquefaction cycle [J].
Atrey, MD .
CRYOGENICS, 1998, 38 (12) :1199-1206
[2]   Optimization of a liquefaction plant using genetic algorithms [J].
Cammarata, G ;
Fichera, A ;
Guglielmino, D .
APPLIED ENERGY, 2001, 68 (01) :19-29
[3]   Optimum number of stages and intermediate pressure level for highest exergy efficiency in large helium liquefiers [J].
Thomas, Rijo Jacob ;
Ghosh, Parthasarathi ;
Chowdhury, Kanchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08) :2438-2457
[4]   Exergy based analysis on different expander arrangements in helium liquefiers [J].
Thomas, Rijo Jacob ;
Ghosh, Parthasarathi ;
Chowdhury, Kanchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04) :1188-1199
[5]   Role of heat exchangers in helium liquefaction cycles: Simulation studies using Collins cycle [J].
Thomas, Rijo Jacob ;
Ghosh, Parthasarathi ;
Chowdhury, Kanchan .
FUSION ENGINEERING AND DESIGN, 2012, 87 (01) :39-46
[6]   Exergy analysis of helium liquefaction systems based on modified Claude cycle with two-expanders [J].
Thomas, Rijo Jacob ;
Ghosh, Parthasarathi ;
Chowdhury, Kanchan .
CRYOGENICS, 2011, 51 (06) :287-294