Measurement and simulation of the pressure ratio between the two traps of double Penning trap mass spectrometers

被引:11
|
作者
Neidherr, D. [1 ]
Blaum, K. [1 ,2 ]
Block, M. [2 ]
Ferrer, R. [1 ]
Herfurth, F. [2 ]
Ketelaer, J. [1 ]
Nagy, Sz. [1 ]
Weber, C. [3 ]
机构
[1] Johannes Gutenberg Univ Mainz, Inst Phys, D-55099 Mainz, Germany
[2] GSI Darmstadt, D-64291 Darmstadt, Germany
[3] Univ Jyvaskyla, Dept Phys, Jyvaskyla 40014, Finland
关键词
Penning traps; Mass spectrometry; Pressure ratio;
D O I
10.1016/j.nimb.2008.05.102
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Penning traps are ideal tools to perform high-precision mass measurements. For this purpose the cyclotron frequency of the stored charged particles is measured. In case of on-line mass measurements of short-lived nuclides produced at radioactive beam facilities the ions get in general first prepared and cooled by buffer-gas collisions in a preparation trap to reduce their motional amplitudes and are then transported to a precision trap for the cyclotron frequency determination. In modern Penning trap mass spectrometers both traps are placed in the homogeneous region of one superconducting magnet to optimize the transport efficiency. Because the gas pressure inside the precision trap has to be very low in order to minimize the damping of the ion motion caused by collisions with rest gas molecules during the frequency determination, a pumping barrier is installed between both traps. To predict the pressure difference between the two traps in the region of molecular gas flow the motion of each particle can be simulated without consideration of the other particles. Thus, it is possible to calculate the transit probability through a tube of a given geometry. The results are compared with experimentally obtained pressure differences. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:4556 / 4559
页数:4
相关论文
共 50 条
  • [31] Design of a β-detector for TITAN-EC and the first electron-capture branching ratio measurement in a Penning trap
    Brunner, T.
    Brodeur, M.
    Ettenauer, S.
    Gallant, A. T.
    Gernhaeuser, R.
    Lapierre, A.
    Ringle, R.
    Sjue, S. K. L.
    Delheij, P.
    Frekers, D.
    Kruecken, R.
    Zuber, K.
    Dilling, J.
    INTERNATIONAL NUCLEAR PHYSICS CONFERENCE 2010 (INPC2010): NEUTRINOS AND NUCLEI, 2011, 312
  • [32] Octupolar-Excitation Penning-Trap Mass Spectrometry for Q-Value Measurement of Double-Electron Capture in 164Er
    Eliseev, S.
    Roux, C.
    Blaum, K.
    Block, M.
    Droese, C.
    Herfurth, F.
    Kretzschmar, M.
    Krivoruchenko, M. I.
    Ramirez, E. Minaya
    Novikov, Yu N.
    Schweikhard, L.
    Shabaev, V. M.
    Simkovic, F.
    Tupitsyn, I. I.
    Zuber, K.
    Zubova, N. A.
    PHYSICAL REVIEW LETTERS, 2011, 107 (15)
  • [33] Theory of photorefractive effect for double carriers with two deep traps and a shallow hole trap
    Li, YQ
    Liu, ST
    Sun, WJ
    Xu, KB
    Hong, J
    ACTA PHYSICA SINICA-OVERSEAS EDITION, 1997, 6 (06): : 413 - 421
  • [34] New mass measurement of 6Li and ppb-level systematic studies of the Penning trap mass spectrometer TITAN
    Brodeur, M.
    Brunner, T.
    Champagne, C.
    Ettenauer, S.
    Smith, M.
    Lapierre, A.
    Ringle, R.
    Ryjkov, V. L.
    Audi, G.
    Delheij, P.
    Lunney, D.
    Dilling, J.
    PHYSICAL REVIEW C, 2009, 80 (04):
  • [35] Phase-Imaging Ion-Cyclotron-Resonance technique at the JYFLTRAP double Penning trap mass spectrometer
    Nesterenko, D. A.
    Eronen, T.
    Kankainen, A.
    Canete, L.
    Jokinen, A.
    Moore, I. D.
    Penttila, H.
    Rinta-Antila, S.
    de Roubin, A.
    Vilen, M.
    EUROPEAN PHYSICAL JOURNAL A, 2018, 54 (09):
  • [36] Phase-Imaging Ion-Cyclotron-Resonance technique at the JYFLTRAP double Penning trap mass spectrometer
    D. A. Nesterenko
    T. Eronen
    A. Kankainen
    L. Canete
    A. Jokinen
    I. D. Moore
    H. Penttilä
    S. Rinta-Antila
    A. de Roubin
    M. Vilen
    The European Physical Journal A, 2018, 54
  • [37] Determination of the proton mass from a measurement of the cyclotron frequencies of D+ and H2+ in a Penning trap
    Solders, A.
    Bergstroem, I.
    Nagy, Sz.
    Suhonen, M.
    Schuch, R.
    PHYSICAL REVIEW A, 2008, 78 (01):
  • [38] Theory, simulation and measurement of chemical mass shifts in RF quadrupole ion traps
    Plass, WR
    Li, HY
    Cooks, RG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 228 (2-3) : 237 - 267
  • [39] Correlation between y-Type Ions Observed in Ion Trap and Triple Quadrupole Mass Spectrometers
    Sherwood, Carly A.
    Eastham, Ashley
    Lee, Lik Wee
    Risler, Jenni
    Vitek, Olga
    Martin, Daniel B.
    JOURNAL OF PROTEOME RESEARCH, 2009, 8 (09) : 4243 - 4251
  • [40] Penning-trap measurement of the Q value of electron capture in 163Ho for the determination of the electron neutrino mass
    Schweiger, Christoph
    Brass, Martin
    Debierre, Vincent
    Door, Menno
    Dorrer, Holger
    Duellmann, Christoph E.
    Enss, Christian
    Filianin, Pavel
    Gastaldo, Loredana
    Harman, Zoltan
    Haverkort, Maurits W.
    Herkenhoff, Jost
    Indelicato, Paul
    Keitel, Christoph H.
    Kromer, Kathrin
    Lange, Daniel
    Novikov, Yuri N.
    Renisch, Dennis
    Rischka, Alexander
    Schuessler, Rima X.
    Eliseev, Sergey
    Blaum, Klaus
    NATURE PHYSICS, 2024, 20 (06) : 921 - 927