Measurement and simulation of the pressure ratio between the two traps of double Penning trap mass spectrometers

被引:11
|
作者
Neidherr, D. [1 ]
Blaum, K. [1 ,2 ]
Block, M. [2 ]
Ferrer, R. [1 ]
Herfurth, F. [2 ]
Ketelaer, J. [1 ]
Nagy, Sz. [1 ]
Weber, C. [3 ]
机构
[1] Johannes Gutenberg Univ Mainz, Inst Phys, D-55099 Mainz, Germany
[2] GSI Darmstadt, D-64291 Darmstadt, Germany
[3] Univ Jyvaskyla, Dept Phys, Jyvaskyla 40014, Finland
关键词
Penning traps; Mass spectrometry; Pressure ratio;
D O I
10.1016/j.nimb.2008.05.102
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Penning traps are ideal tools to perform high-precision mass measurements. For this purpose the cyclotron frequency of the stored charged particles is measured. In case of on-line mass measurements of short-lived nuclides produced at radioactive beam facilities the ions get in general first prepared and cooled by buffer-gas collisions in a preparation trap to reduce their motional amplitudes and are then transported to a precision trap for the cyclotron frequency determination. In modern Penning trap mass spectrometers both traps are placed in the homogeneous region of one superconducting magnet to optimize the transport efficiency. Because the gas pressure inside the precision trap has to be very low in order to minimize the damping of the ion motion caused by collisions with rest gas molecules during the frequency determination, a pumping barrier is installed between both traps. To predict the pressure difference between the two traps in the region of molecular gas flow the motion of each particle can be simulated without consideration of the other particles. Thus, it is possible to calculate the transit probability through a tube of a given geometry. The results are compared with experimentally obtained pressure differences. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:4556 / 4559
页数:4
相关论文
共 50 条
  • [21] DETERMINATION OF THE ELECTRONS ATOMIC MASS AND THE PROTON/ELECTRON MASS-RATIO VIA PENNING TRAP MASS-SPECTROSCOPY
    FARNHAM, DL
    VANDYCK, RS
    SCHWINBERG, PB
    PHYSICAL REVIEW LETTERS, 1995, 75 (20) : 3598 - 3601
  • [22] A simulation study of coupled secular oscillations in nonlinear Paul trap mass spectrometers
    Sevugarajan, S
    Menon, AG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 209 (2-3) : 209 - 226
  • [23] Simulations of the novel double-Penning trap for MLLTRAP: Trapping, cooling and mass measurements
    Chauveau, P.
    Hauschild, K.
    Lopez-Martens, A.
    MacCormick, M.
    Ramirez, E. Minaya
    Thirolf, P. G.
    Weber, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 982
  • [24] Precision measurement of the atomic mass of 6Li using a Penning ion trap mass spectrometer
    Heavner, TP
    Jefferts, SR
    Dunn, GH
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 104 - 105
  • [25] Precision measurement of the atomic mass of 6Li using a Penning ion trap mass spectrometer
    Heavner, TP
    Jefferts, SR
    Dunn, GH
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 189 - 191
  • [26] Improving the measurement sensitivity of the Canadian Penning Trap mass spectrometer through PI-ICR
    Orford, R.
    Clark, J. A.
    Savard, G.
    Aprahamian, A.
    Buchinger, F.
    Burkey, M. T.
    Gorelov, D. A.
    Klimes, J. W.
    Morgan, G. E.
    Nystrom, A.
    Porter, W. S.
    Ray, D.
    Sharma, K. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 463 (463): : 491 - 495
  • [27] Optimization of a supercritical fluid chromatograph atmospheric pressure chemical ionization mass spectrometer interface using an ion trap and two quadrupole mass spectrometers
    Morgan, DG
    Harbol, KL
    Kitrinos, NP
    JOURNAL OF CHROMATOGRAPHY A, 1998, 800 (01) : 39 - 49
  • [28] First Penning-Trap Mass Measurement of the Exotic Halo Nucleus 11Li
    Smith, M.
    Brodeur, M.
    Brunner, T.
    Ettenauer, S.
    Lapierre, A.
    Ringle, R.
    Ryjkov, V. L.
    Ames, F.
    Bricault, P.
    Drake, G. W. F.
    Delheij, P.
    Lunney, D.
    Sarazin, F.
    Dilling, J.
    PHYSICAL REVIEW LETTERS, 2008, 101 (20)
  • [29] Dynamics of an unbalanced two-ion crystal in a Penning trap for application in optical mass spectrometry
    Gutierrez, M. J.
    Berrocal, J.
    Dominguez, F.
    Arrazola, I
    Block, M.
    Solano, E.
    Rodriguez, D.
    PHYSICAL REVIEW A, 2019, 100 (06)
  • [30] Perturbation between two traps in dual-trap optical tweezers
    Ling, Lin
    Zhou, Fei
    Huang, Lu
    Guo, Honglian
    Li, Zhaolin
    Li, Zhi-Yuan
    JOURNAL OF APPLIED PHYSICS, 2011, 109 (08)