Indwelling device-related bacteremia caused by serum-susceptible Campylobacter coli

被引:6
|
作者
Hsueh, PR
Teng, LJ
Yang, PC
Ho, SW
Luh, KT
机构
[1] NATL TAIWAN UNIV HOSP,DEPT LAB MED,TAIPEI,TAIWAN
[2] NATL TAIWAN UNIV HOSP,DEPT INTERNAL MED,TAIPEI,TAIWAN
[3] NATL TAIWAN UNIV,COLL MED,SCH MED TECHNOL,TAIPEI 10018,TAIWAN
关键词
D O I
10.1128/JCM.35.8.2178-2180.1997
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Two isolates of serum-susceptible Campylobacter coli were recovered in a 7-day interval from blood! from a patient with hepatocellular carcinoma and liver cirrhosis whose peritoneal-caval (Denver's) shunt malfunctioned, Identical random amplified polymorphic DNA fingerprints, cellular fatty acid chromatograms, and antibiograms of the two isolates indicate that, C. coli has the ability to cause catheter-related bacteremia following its colonization or the catheter.
引用
收藏
页码:2178 / 2180
页数:3
相关论文
共 23 条
  • [1] Indwelling device-related and recurrent infections due to Aeromonas species
    Hsueh, PR
    Teng, LJ
    Lee, LN
    Yang, PC
    Chen, YC
    Ho, SW
    Luh, KT
    CLINICAL INFECTIOUS DISEASES, 1998, 26 (03) : 651 - 658
  • [2] SEROLOGIC DIAGNOSIS OF ACCESS DEVICE-RELATED STAPHYLOCOCCAL BACTEREMIA
    WHEAT, LJ
    LUFT, FC
    TABBARAH, Z
    KOHLER, RB
    WHITE, A
    AMERICAN JOURNAL OF MEDICINE, 1979, 67 (04) : 603 - 607
  • [3] Preventing Device-Related Pressure Ulcers From Indwelling Arterial Catheters
    Tan, Fe
    Mako, Julieta
    CRITICAL CARE NURSE, 2019, 39 (02) : E42 - E42
  • [4] The timing and sequence of multiple device-related complications in patients with indwelling subcutaneous ports
    Young, C
    Gould, JR
    AMERICAN JOURNAL OF SURGERY, 1997, 174 (04) : 417 - 421
  • [5] Cardiac Device-Related Endocarditis Caused by Paenibacillus glucanolyticus
    Ferrand, Janina
    Hadou, Tahar
    Selton-Suty, Christine
    Goehringer, Francois
    Sadoul, Nicolas
    Alauzet, Corentine
    Lozniewski, Alain
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (10) : 3439 - 3442
  • [6] Transesophageal echocardiography negative cardiac implantable electronic device-related endocarditis in a patient with persistent methicillin-susceptible staphylococcus aureus bacteremia
    Afroze, T.
    Sleem, M.
    Hafiz, S.
    Roy, A.
    Tanami, S. A.
    Abdelsalam, M.
    Saadaldin, M.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2024, 367 : S99 - S100
  • [7] Oxacillin plus ertapenem rapidly clears persistent left ventricular assist device-related methicillin-susceptible Staphylococcus aureus bacteremia
    Wilsey, H. Andrew
    Pisani, Barbara
    O'Neill, Thomas J.
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (07) : 2127 - 2130
  • [8] Complement-mediated bactericidal activity of human milk to a serum-susceptible strain of E-coli 0111
    Ogundele, MO
    JOURNAL OF APPLIED MICROBIOLOGY, 1999, 87 (05) : 689 - 696
  • [9] The timing and sequence of multiple device-related complications in patients with long term indwelling Groshong catheters
    Tolar, B
    Gould, JR
    CANCER, 1996, 78 (06) : 1308 - 1313
  • [10] Indwelling catheters and medical implants with FXIIIa inhibitors: A novel approach to the treatment of catheter and medical device-related infections
    Daneshpour, Nooshin
    Collighan, Russell
    Perrie, Yvonne
    Lambert, Peter
    Rathbone, Dan
    Lowry, Deborah
    Griffin, Martin
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2013, 83 (01) : 106 - 113