Data-independent screening method for 14 fentanyl analogs in whole blood and oral fluid using LC-QTOF-MS

被引:31
作者
Palmquist, Kaitlyn B. [1 ]
Swortwood, Madeleine J. [1 ]
机构
[1] Sam Houston State Univ, Dept Forens Sci, Coll Criminal Justice, Huntsville, TX 77340 USA
关键词
Fentanyl analogs; Postmortem blood; Oral fluid; Novel synthetic opioids; High resolution mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; ACETYL FENTANYL; QUANTITATIVE-ANALYSIS; SYNTHETIC OPIOIDS; FURANYL FENTANYL; POSTMORTEM; URINE; METABOLITES; MS/MS; REDISTRIBUTION;
D O I
10.1016/j.forsciint.2019.02.006
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Recently, fentanyl analogs account for significant number of opioid deaths in the United States. Routine forensic analyses are often unable to detect and differentiate these analogs due to low concentrations and presence of structural isomers. A data-independent screening method for 14 fentanyl analogs in whole blood and oral fluid was developed and validated using liquid chromatography-quadrupole-time-offlight mass spectrometry (LC-QTOF-MS). Data were acquired using Time of Flight (TOF) and All Ions Fragmentation (AIF) modes. The limits of detection (LOD) in blood were 0.1-1.0 ng/mL and 0.1-1.0 ng/mL in TOF and AIF modes, respectively. In oral fluid, the LODs were 0.25 ng/mL and 0.25-2.5 ng/mL in TOF and AIF modes, respectively. Matrix effects in blood were acceptable for most analytes (1-14.4%), while the nor-metabolites exhibited ion suppression >25%. Matrix effects in oral fluid were -11.7 to 13.3%. Stability was assessed after 24 h in the autosampler (4 degrees C) and refrigerator (4 degrees C). Processed blood and oral fluid samples were considered stable with -14.6 to 4.6% and -10.1 to 2.3% bias, respectively. For refrigerated stability, bias was -23.3 to 8.2% (blood) and -20.1 to 20.0% (oral fluid). Remifentanil exhibited >20% loss in both matrices. For proof of applicability, postmortem blood (n = 30) and oral fluid samples (n = 20) were analyzed. As a result, six fentanyl analogs were detected in the blood samples with furanyl fentanyl and 4ANN) being the most prevalent. No fentanyl analogs were detected in the oral fluid samples. This study presents a validated screening technique for fentanyl analogs in whole blood and oral fluid using LCQTOF-MS with low limits of detection. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 43 条
[2]   Opioid intoxications involving butyrfentanyl, 4-fluorobutyrfentanyl, and fentanyl from the Swedish STRIDA project [J].
Backberg, Matilda ;
Beck, Olof ;
Jonsson, Karl-Henrik ;
Helander, Anders .
CLINICAL TOXICOLOGY, 2015, 53 (07) :609-617
[3]   Fentanyl laced heroin and its contribution to a spike in heroin overdose in Miami-Dade County [J].
Bode, Alexander Diaz ;
Singh, Mallika ;
Andrews, James ;
Kapur, Girish B. ;
Baez, Amado Alejandro .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (09) :1364-1365
[4]   Development of a quantitative approach in blood plasma for low-dosed hallucinogens and opioids using LC-high resolution mass spectrometry [J].
Caspar, Achim T. ;
Kollas, Andreas B. ;
Maurer, Hans H. ;
Meyer, Markus R. .
TALANTA, 2018, 176 :635-645
[5]   The distribution and redistribution of fentanyl & norfentanyl in post mortem samples [J].
Chatterton, C. N. ;
Scott-Ham, M. .
FORENSIC SCIENCE INTERNATIONAL, 2018, 284 :146-152
[6]   Fatal Intoxication with Acetyl Fentanyl [J].
Cunningham, Susan M. ;
Haikal, Nabila A. ;
Kraner, James C. .
JOURNAL OF FORENSIC SCIENCES, 2016, 61 :S276-S280
[7]   Overdose Deaths Related to Fentanyl and Its Analogs - Ohio, January-February 2017 [J].
Daniulaityte, Raminta ;
Juhascik, Matthew P. ;
Strayer, Kraig E. ;
Sizemore, Ioana E. ;
Harshbarger, Kent E. ;
Antonides, Heather M. ;
Carlson, Robert R. .
MMWR-MORBIDITY AND MORTALITY WEEKLY REPORT, 2017, 66 (34) :904-908
[8]  
Drug Enforcement Administration, 2018, DRUG SCHED
[9]  
Drug Enforcement Administration, 2018, US DRUG ENF ADM EM S
[10]   Development of a new multi-analyte assay for the simultaneous detection of opioids in serum and other body fluids using liquid chromatography-tandem mass spectrometry [J].
Eckart, K. ;
Roehrich, J. ;
Breitmeier, D. ;
Ferner, M. ;
Laufenberg-Feldmann, R. ;
Urban, R. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1001 :1-8