Agreement and Reproducibility of Apparent Diffusion Coefficient Measurements of Dual-b-Value and Multi-b-Value Diffusion-Weighted Magnetic Resonance Imaging at 1.5 Tesla in Phantom and in Soft Tissues of the Abdomen

被引:38
作者
Corona-Villalobos, Celia Pamela [1 ]
Pan, Li [1 ,2 ]
Halappa, Vivek Gowdra [1 ]
Bonekamp, Susanne [1 ]
Lorenz, Christine H. [1 ,2 ]
Eng, John [1 ]
Kamel, Ihab R. [1 ]
机构
[1] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Siemens Corp Res, Ctr Appl Med Imaging, Baltimore, MD USA
关键词
diffusion-weighted imaging; apparent diffusion coefficient; phantom; abdominal imaging; TREATMENT RESPONSE; BREATH-HOLD; MRI; CANCER; LIVER; ONCOLOGY; THERAPY; LESIONS; CELLULARITY; CARCINOMA;
D O I
10.1097/RCT.0b013e3182720e07
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the coefficient of variation (CV) and long-term reproducibility of apparent diffusion coefficient (ADC) in a simple fluid-filled phantom and abdominal organs simultaneously. Materials and Methods: Retrospective institutional review board-approved and Health Insurance Portability and Accountability Act-compliant study sequentially selected 100 patients who underwent clinically indicated abdominal magnetic resonance imaging. A subset of 58 patients had repeat scans within 2 to 5 months after the initial magnetic resonance imaging. Two diffusion-weighted imaging techniques (b-values 0Y750 mm(2)/s) were performed to compare the ADC values. Mean ADC values were calculated for 10 locations and the reference phantom. The CV and Bland-Altman plots were calculated for the phantom and soft tissues at each session and location. Results: There were no significant differences in the mean ADC values between repeated acquisitions. However, ADC values were statistically higher using dual-b-value than multi-b-value diffusion-weighted imaging. The CV for the phantom was 8.6 versus 10.8 for dual-b-value and multi-b-value, respectively. The CVs for the soft tissues had a wider range compared with that of the phantom (liver, 12.6 vs 9.0; spleen, 11.7 vs 11.2; gallbladder, 11.0 vs 13.6; head of pancreas, 14.6 vs 14.7; body of pancreas, 13.4 vs 13.0; tail of pancreas, 14.8 vs 16.3; right kidney, 9.1 vs 9.6; left kidney, 9.3 vs 9.3; right paraspinal muscle, 7.9 vs 7.5; left paraspinal muscle, 7.3 vs 7.3, respectively). Conclusions: A change in ADC less than 11% falls into the range of measurement variability. Paraspinal muscle could potentially be used as an internal reference parameter.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 35 条
[11]   Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): features and potential applications in oncology [J].
Kwee, Thomas C. ;
Takahara, Taro ;
Ochiai, Reiji ;
Nievelstein, Rutger A. J. ;
Luijten, Peter R. .
EUROPEAN RADIOLOGY, 2008, 18 (09) :1937-1952
[12]   DIFFUSION MR IMAGING - CLINICAL-APPLICATIONS [J].
LEBIHAN, D ;
TURNER, R ;
DOUEK, P ;
PATRONAS, N .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (03) :591-599
[13]   MAGNETIC-RESONANCE DIFFUSION PERFUSION PHANTOM EXPERIMENTS [J].
LORENZ, CH ;
PICKENS, DR ;
PUFFER, DB ;
PRICE, RR .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :254-260
[14]   Diffusion-weighted MRI (DWI) in the oncology patient: Value of breathhold DWI compared to unenhanced and gadolinium-enhanced MRI [J].
Low, Russell N. ;
Gurney, Jonathan .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) :848-858
[15]   Early detection of response to radiation therapy in patients with brain malignancies using conventional and high b-value diffusion-weighted magnetic resonance imaging [J].
Mardor, Y ;
Pfeffer, R ;
Spiegelmann, R ;
Roth, Y ;
Maier, SE ;
Nissim, O ;
Berger, R ;
Glicksman, A ;
Baram, J ;
Orenstein, A ;
Cohen, JS ;
Tichler, T .
JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (06) :1094-1100
[16]   Apparent Diffusion Coefficient in Invasive Ductal Breast Carcinoma: Correlation with Detailed Histologic Features and the Enhancement Ratio on Dynamic Contrast-Enhanced MR Images [J].
Matsubayashi, Roka Namoto ;
Fujii, Teruhiko ;
Yasumori, Kotaro ;
Muranaka, Toru ;
Momosaki, Seiya .
JOURNAL OF ONCOLOGY, 2010, 2010
[17]  
Merkle Elmar M, 2006, Magn Reson Imaging Clin N Am, V14, P17, DOI 10.1016/j.mric.2005.12.001
[18]   Diffusion MR Imaging for Monitoring of Treatment Response [J].
Padhani, Anwar R. ;
Koh, Dow-Mu .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2011, 19 (01) :181-+
[19]   Diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for monitoring anticancer therapy [J].
Padhani, Anwar R. ;
Khan, Aftab Alam .
TARGETED ONCOLOGY, 2010, 5 (01) :39-52
[20]   Focal liver lesion detection and characterization with diffusion-weighted MR imaging: Comparison with standard breath-hold T2-weighted imaging [J].
Parikh, Tejas ;
Drew, Stephen J. ;
Lee, Vivian S. ;
Wong, Samson ;
Hecht, Elizabeth M. ;
Babb, James S. ;
Taouli, Bachir .
RADIOLOGY, 2008, 246 (03) :812-822