Agreement and Reproducibility of Apparent Diffusion Coefficient Measurements of Dual-b-Value and Multi-b-Value Diffusion-Weighted Magnetic Resonance Imaging at 1.5 Tesla in Phantom and in Soft Tissues of the Abdomen

被引:38
作者
Corona-Villalobos, Celia Pamela [1 ]
Pan, Li [1 ,2 ]
Halappa, Vivek Gowdra [1 ]
Bonekamp, Susanne [1 ]
Lorenz, Christine H. [1 ,2 ]
Eng, John [1 ]
Kamel, Ihab R. [1 ]
机构
[1] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Siemens Corp Res, Ctr Appl Med Imaging, Baltimore, MD USA
关键词
diffusion-weighted imaging; apparent diffusion coefficient; phantom; abdominal imaging; TREATMENT RESPONSE; BREATH-HOLD; MRI; CANCER; LIVER; ONCOLOGY; THERAPY; LESIONS; CELLULARITY; CARCINOMA;
D O I
10.1097/RCT.0b013e3182720e07
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the coefficient of variation (CV) and long-term reproducibility of apparent diffusion coefficient (ADC) in a simple fluid-filled phantom and abdominal organs simultaneously. Materials and Methods: Retrospective institutional review board-approved and Health Insurance Portability and Accountability Act-compliant study sequentially selected 100 patients who underwent clinically indicated abdominal magnetic resonance imaging. A subset of 58 patients had repeat scans within 2 to 5 months after the initial magnetic resonance imaging. Two diffusion-weighted imaging techniques (b-values 0Y750 mm(2)/s) were performed to compare the ADC values. Mean ADC values were calculated for 10 locations and the reference phantom. The CV and Bland-Altman plots were calculated for the phantom and soft tissues at each session and location. Results: There were no significant differences in the mean ADC values between repeated acquisitions. However, ADC values were statistically higher using dual-b-value than multi-b-value diffusion-weighted imaging. The CV for the phantom was 8.6 versus 10.8 for dual-b-value and multi-b-value, respectively. The CVs for the soft tissues had a wider range compared with that of the phantom (liver, 12.6 vs 9.0; spleen, 11.7 vs 11.2; gallbladder, 11.0 vs 13.6; head of pancreas, 14.6 vs 14.7; body of pancreas, 13.4 vs 13.0; tail of pancreas, 14.8 vs 16.3; right kidney, 9.1 vs 9.6; left kidney, 9.3 vs 9.3; right paraspinal muscle, 7.9 vs 7.5; left paraspinal muscle, 7.3 vs 7.3, respectively). Conclusions: A change in ADC less than 11% falls into the range of measurement variability. Paraspinal muscle could potentially be used as an internal reference parameter.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 35 条
[1]   Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations [J].
不详 .
NEOPLASIA, 2009, 11 (02) :102-125
[2]   Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen [J].
Braithwaite, Adam C. ;
Dale, Brian M. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
RADIOLOGY, 2009, 250 (02) :459-465
[3]  
Charles-Edwards Elizabeth M, 2006, Cancer Imaging, V6, P135, DOI 10.1102/1470-7330.2006.0021
[4]   Field Strength and Diffusion Encoding Technique Affect the Apparent Diffusion Coefficient Measurements in Diffusion-Weighted Imaging of the Abdomen [J].
Dale, Brian M. ;
Braithwaite, Adam C. ;
Boll, Daniel T. ;
Merkle, Elmar M. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (02) :104-108
[5]   Diffusion and perfusion imaging in subacute neurotoxicity following high-dose intravenous methotrexate [J].
Eichler, April F. ;
Batchelor, Tracy T. ;
Henson, John W. .
NEURO-ONCOLOGY, 2007, 9 (03) :373-377
[6]   Differentiation of clinically benign and malignant breast lesions using diffusion-weighted imaging [J].
Guo, Y ;
Cai, YQ ;
Cai, ZL ;
Gao, YG ;
An, NY ;
Ma, L ;
Mahankali, S ;
Gao, JH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :172-178
[7]   Diffusion magnetic resonance imaging: A biomarker for treatment response in oncology [J].
Hamstra, Daniel A. ;
Rehemtulla, Alnawaz ;
Ross, Brian D. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (26) :4104-4109
[8]   Functional MR imaging assessment of tumor response after 90Y microsphere treatment in patients with unresectable hepatocellular carcinoma [J].
Kamel, Ihab R. ;
Reyes, Diane K. ;
Liapi, Eleni ;
Bluemke, David A. ;
Geschwind, Jean-Francois H. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (01) :49-56
[9]   Malignant Hepatic Tumors: Short-term Reproducibility of Apparent Diffusion Coefficients with Breath-hold and Respiratory-triggered Diffusion-weighted MR Imaging [J].
Kim, So Yeon ;
Lee, Seung Soo ;
Byun, Jae Ho ;
Park, Seong Ho ;
Kim, Jeong Kon ;
Park, Bumwoo ;
Kim, Namkug ;
Lee, Moon-Gyu .
RADIOLOGY, 2010, 255 (03) :815-823
[10]   Functional Magnetic Resonance Imaging of the Liver: Parametric Assessments Beyond Morphology [J].
Koh, Dow-Mu ;
Padhani, Anwar R. .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2010, 18 (03) :565-+