PURPOSE: To evaluate the agreement of higher-order aberrations (HOAs) between aberrometers based on the Hartmann-Shack wavefront technology. SETTING: Department of Ophthalmology, Tri-Service General Hospital, Taipei, Taiwan. METHODS: Three clinical aberrometers WaveScan (Visx Inc.), LADARWave (Alcon Inc.), and Zywave (Bausch & Lomb Inc.) were used to measure HOAs in 34 cycloplegic eyes in 17 subjects. All the measurements in each subject were performed in I visit to reduce the impact of biologic fluctuation of HOAs. Each device was operated by an independent experienced operator, and the operators were blind to the data obtained from the other aberrometers. Root mean square (RMS) of coma, spherical aberration, and total 3rd- and 4th-order HOAs were compared between any 2 devices by a paired t test. RESULTS: WaveScan had the lowest mean RMS, whereas Zywave reported the highest mean RMS for any HOAs. The coefficients of variation were similar between any 2 devices. Paired t tests of RMS yielded a P value <.01 in 9 of 12 comparisons. In general, the largest discrepancies of HOA measures were between WaveScan and Zywave, and similar data were found between LADARWave and WaveScan. More than 80% of the absolute difference of HOA RMS between LADARWave and WaveScan, 50% to 78% between LADARWave and Zywave, and 38% to 59% between WaveScan and Zywave were within +/- 0.1 mu m. CONCLUSIONS: Significant discrepancies in HOA measurements were found among the 3 popular aberrometers. The HOA RMS data were closer between LADARWave and WaveScan, and HOA RMS by Zywave was generally higher than the other 2 devices. The 3 devices had comparable measurement variation.
引用
收藏
页码:2153 / 2156
页数:4
相关论文
共 9 条
[1]   Test-retest reliability of clinical Shack-Hartmann measurements [J].
Cheng, X ;
Himebaugh, NL ;
Kollbaum, PS ;
Thibos, LN ;
Bradley, A .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (01) :351-360
[2]   OBJECTIVE MEASUREMENT OF WAVE ABERRATIONS OF THE HUMAN EYE WITH THE USE OF A HARTMANN-SHACK WAVE-FRONT SENSOR [J].
LIANG, JZ ;
GRIMM, B ;
GOELZ, S ;
BILLE, JF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (07) :1949-1957
[3]   In vivo and in vitro repeatability of Hartmann-Shack aberrometry [J].
Mirshahi, A ;
Bühren, J ;
Gerhardt, D ;
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (12) :2295-2301
[4]  
Nagy ZZ, 2002, J REFRACT SURG, V18, pS615
[5]   Wavefront-guided versus standard laser in situ keratomileusis to correct low to moderate myopia [J].
Nuijts, RMMA ;
Nabar, VA ;
Hament, WJ ;
Eggink, FAGJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (11) :1907-1913
[6]   Statistical variation of aberration structure and image quality in a normal population of healthy eyes [J].
Thibos, LN ;
Hong, X ;
Bradley, A ;
Cheng, X .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (12) :2329-2348
[7]   Evaluation of refractive error measurements of the WaveScan WaveFront system and the Tracey wavefront aberrometer [J].
Wang, L ;
Wang, N ;
Koch, DD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :970-979
[8]   Ocular higher-order aberrations in individuals screened for refractive surgery [J].
Wang, L ;
Koch, DD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (10) :1896-1903
[9]  
Williams D, 2000, J REFRACT SURG, V16, pS554