Real-time assessment of cigarette smoke particle deposition in vitro

被引:23
作者
Adamson, Jason [1 ]
Hughes, Sophie [1 ]
Azzopardi, David [1 ]
McAughey, John [1 ]
Gaca, Marianna D. [1 ]
机构
[1] British Amer Tobacco, Grp R&D, Southampton SO15 8TL, Hants, England
关键词
QCM; Cigarette smoke; In vitro exposure chamber; Dosimetry; EXPOSURE SYSTEM; TOBACCO-SMOKE; NANOPARTICLE TOXICITY; CELLS; MACHINE;
D O I
10.1186/1752-153X-6-98
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Background: Recently there has been a rapid increase in approaches to assess the effects of cigarette smoke in vitro. Despite a range of gravimetric and chemical methods, there is a requirement to identify simpler and more reliable methods to quantify in vitro whole smoke dose, to support extrapolation and comparisons to human/in vivo dose. We have previously characterised an in vitro exposure system using a Borgwaldt RM20S smoking machine and a chamber exposing cellular cultures to whole smoke at the air-liquid interface. In this study we demonstrate the utility of a quartz crystal microbalance (QCM), using this exposure system, to assess real-time cigarette smoke particulate deposition during a 30 minute smoke exposure. Smoke was generated at various dilutions (1:5-1:400, smoke: air) using two cigarette products, 3R4F Kentucky reference and 1 mg commercially available cigarettes. The QCM, integrated into the chamber, assessed particulate deposition and data generated were compared to traditional chemical spectrofluorometric analysis. Results: The QCM chamber was able to detect mass differences between the different products within the nanogram range. 3R4F reference cigarette smoke deposition ranged from 25.75 +/- 2.30 mu g/cm(2) (1:5) to 0.22 +/- 0.03 mu g/cm(2) (1:400). 1 mg cigarette smoke deposition was less and ranged from 1.42 +/- 0.26 mu g/cm(2) (1:5), to 0.13 +/- 0.02 mu g/cm(2) (1:100). Spectrofluorometric analysis demonstrated statistically significant correlation of particulate deposition with the QCM (p < 0.05), and regression R-2 value were 97.4 %. The fitted equation for the linear model which describes the relationship is: QCM = -0.6796 + 0.9744 chemical spectrofluorescence. Conclusions: We suggest the QCM is a reliable, effective and simple tool that can be used to quantify smoke particulate deposition in real-time, in vitro and can be used to quantify other aerosols delivered to our chamber for assessment.
引用
收藏
页数:11
相关论文
共 32 条
[1]   Assessment of an in vitro whole cigarette smoke exposure system: The Borgwaldt RM20S 8-syringe smoking machine [J].
Adamson, Jason ;
Azzopardi, David ;
Errington, Graham ;
Dickens, Colin ;
McAughey, John ;
Gaca, Marianna D. .
CHEMISTRY CENTRAL JOURNAL, 2011, 5
[2]   Evaluation of the TEOM(R) method for measurement of ambient particulate mass in urban areas [J].
Allen, G ;
Sioutas, C ;
Koutrakis, P ;
Reiss, R ;
Lurmann, FW ;
Roberts, PT .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (06) :682-689
[3]  
[Anonymous], 4387 ISO
[4]  
[Anonymous], 3402 ISO
[5]  
Armitage A. K., 2004, Beitraege zur Tabakforschung International, V21, P240
[6]   An improved in vitro model for testing the pulmonary toxicity of complex mixtures such as cigarette smoke [J].
Aufderheide, M ;
Knebel, JW ;
Ritter, D .
EXPERIMENTAL AND TOXICOLOGIC PATHOLOGY, 2003, 55 (01) :51-57
[7]  
Baron PaulA., 2005, AEROSOL MEASUREMENT, V2nd
[8]   FIXATION OF TOBACCO-SMOKE AEROSOLS FOR SIZE DISTRIBUTION STUDIES [J].
CARTER, WL ;
HASEGAWA, I .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1975, 53 (01) :134-141
[9]  
Chalupowicz DG, 2008, AM J RESP CRIT CARE, V177, P199
[10]   Modified procedure of a direct in vitro exposure system for mammalian cells to whole cigarette smoke [J].
Fukano, Y ;
Ogura, M ;
Eguchi, K ;
Shibagaki, M ;
Suzuki, M .
EXPERIMENTAL AND TOXICOLOGIC PATHOLOGY, 2004, 55 (05) :317-323