Tentative study on x-ray enhancement by fluorescent emission of radiation by plasma x-ray source

被引:17
作者
Sato, E [1 ]
Sagae, M [1 ]
Ichimaru, T [1 ]
Hayasi, Y [1 ]
Ojima, H [1 ]
Takayama, K [1 ]
Ido, H [1 ]
Sakamaki, K [1 ]
Tamakawa, Y [1 ]
机构
[1] Iwate Med Univ, Dept Phys, Morioka, Iwate 0200015, Japan
来源
RADIATION SOURCES AND RADIATION INTERACTIONS | 1999年 / 3771卷
关键词
flash x-ray; plasma x-ray source; characteristic x-ray; quasi-monochromatic x-ray; x-ray enhancement; fluorescent emission;
D O I
10.1117/12.363707
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Tentative study on characteristic x-ray enhancement by fluorescent emission of radiation by plasma x-ray source is described. The enhancement was performed by the plasma flash x-ray generator having a cold-cathode triode. And the generator employs a high-voltage power supply, a low-impedance coaxial transmission line with a gap switch, a high-voltage condenser with a capacity of 200 nF, a turbo-molecular pump, a thyristor pulser as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 60 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The flash x-rays are then produced. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As the electron flows from the cathode electrode are roughly converged to the target by the electric field in the tube, the plasma x-ray source, which consists of metal ions and electrons, forms by the target evaporating. Both the tube voltage and current displayed damped oscillations, and their peak values increased according to increases in the charging voltage. In the present work, the peak tube voltage was almost equivalent to the initial charging voltage of the main condenser, and the peak current was less than 30 kA. The characteristic x-ray intensity substantially increased according to the growth in the plasma x-ray source. When the linear plasma x-ray source formed, the bremsstrahlung x-rays were absorbed without using a monochromatic filter, and high-intensity characteristic x-rays were produced.
引用
收藏
页码:51 / 60
页数:10
相关论文
共 28 条
  • [1] COLLINS GP, 1994, PHYSICS TODAY OCT, P19
  • [2] X-RAY FLASH TECHNIQUES
    GERMER, R
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1979, 12 (05): : 336 - 350
  • [3] UNDEGASSED AND DEGASSED EXPLODING TUNGSTEN WIRES IN VACUUM
    HOLMSTROM, I
    HANDEL, SK
    STENERHAG, B
    [J]. JOURNAL OF APPLIED PHYSICS, 1968, 39 (07) : 2998 - +
  • [4] DISK-CATHODE FLASH X-RAY TUBE DRIVEN BY A REPETITIVE 2-STAGE MARX PULSER
    KIMURA, S
    SATO, E
    SAGAE, M
    SHIKODA, A
    OIZUMI, T
    TAKAHASHI, K
    TAMAKAWA, Y
    YANAGISAWA, T
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 : S37 - S43
  • [5] SOME CHARACTERISTICS OF A 600 KV FLASH X-RAY TUBE
    MATTSSON, A
    [J]. PHYSICA SCRIPTA, 1972, 5 (1-2): : 99 - &
  • [6] CALCULATION OF CHARACTERISTIC X-RAYS IN DIAGNOSTIC-X-RAY SPECTRUM
    NAKAMORI, N
    YAMANO, K
    YAMADA, M
    KANAMORI, H
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (1A): : 347 - 352
  • [7] OIZUMI T, 1994, SPIE, V2513, P761
  • [8] MEASUREMENT OF FOCAL SPOT SIZE OF DIAGNOSTIC X-RAY TUBES - COMPARISON OF PINHOLE AND RESOLUTION METHODS
    ROBINSON, A
    GRIMSHAW, GM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (571) : 572 - 580
  • [9] DEMONSTRATION OF A DISCHARGE PUMPED TABLE-TOP SOFT-X-RAY LASER
    ROCCA, JJ
    SHLYAPTSEV, V
    TOMASEL, FG
    CORTAZAR, OD
    HARTSHORN, D
    CHILLA, JLA
    [J]. PHYSICAL REVIEW LETTERS, 1994, 73 (16) : 2192 - 2195
  • [10] Ignitron-driven soft flash x-ray generator
    Sagae, M
    Sato, E
    Ichimaru, T
    Obara, H
    Sakamaki, K
    Takayama, K
    Tamakawa, Y
    [J]. ULTRAHIGH- AND HIGH-SPEED PHOTOGRAPHY AND IMAGE-BASED MOTION MEASUREMENT, 1997, 3173 : 194 - 203