CFD study to determine the optimal configuration of aerators in a full-scale waste stabilization pond

被引:25
作者
Alvarado, Andres [1 ,2 ]
Vesvikar, Mehul [2 ]
Cisneros, Juan F. [1 ]
Maere, Thomas [2 ]
Goethals, Peter [3 ]
Nopens, Ingmar [2 ]
机构
[1] Univ Cuenca, DIUC PROMAS, Cuenca, Ecuador
[2] Univ Ghent, Dept Math Modelling Stat & Bioinformat, BIOMATH, B-9000 Ghent, Belgium
[3] Univ Ghent, Dept Appl Ecol & Environm Biol, B-9000 Ghent, Belgium
关键词
Tracer experiment; Aeration; Hydrodynamics; Mixing; Propeller; Scenario analysis; LAGOONS; HYDRAULICS; SEDIMENTS;
D O I
10.1016/j.watres.2013.05.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Aerated lagoons (ALs) are important variants of the pond wastewater treatment technology that have not received much attention in the literature. The hydraulic behaviour of ALs and especially the Facultative aerated lagoons (FALs) is very complex since the aeration in these systems is designed for oxygen transfer but not necessarily to create complete mixing. In this work, the energy expenditure of the aerators was studied by means of a scenario analysis. 3D CFD models (one phase and multiphase) of a 3 ha FAL in a waste stabilization pond system in Cuenca (Ecuador) were built for different configurations of aerators. The thrust produced by the aerators was modelled by an external momentum source applied as velocity vectors into the pond fluid. The predictions of a single phase model were in satisfactory agreement with experimental results. Subsequently, a scenario analysis assessing several aeration schemes with different numbers of aerators in operation were tested with respect to velocity profiles and residence time distribution (RTD) curves. This analysis showed that the aeration scheme with all 10 aerators switched on produces a similar hydraulic behaviour compared to using only 6 or 8 aerators. The current operational schemes comprise of switching off some aerators during the peak hours of the day and operating all 10 aerators during night. This current practice could be economically replaced by continuously operating 4 or 6 aerators without significantly affecting the overall mixing. Furthermore, a continuous mixing regime minimises the sediment oxygen demand enhancing the oxygen levels in the pond. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4528 / 4537
页数:10
相关论文
共 24 条
  • [1] A compartmental model to describe hydraulics in a full-scale waste stabilization pond
    Alvarado, Andres
    Vedantam, Sreepriya
    Goethals, Peter
    Nopens, Ingmar
    [J]. WATER RESEARCH, 2012, 46 (02) : 521 - 530
  • [2] ANSYS Fluent, 2006, Fluent 6.3 User's Guide
  • [3] Blaauw H. G., 1978, PUBLICATION DELFT HY
  • [4] Tracer studies on an aerated lagoon
    Broughton, Alistair
    Shilton, Andy
    [J]. WATER SCIENCE AND TECHNOLOGY, 2012, 65 (04) : 611 - 617
  • [5] Some influences of sediments in aerated lagoons and waste stabilization ponds
    Chabir, D
    El Ouarghi, H
    Brostaux, Y
    Vasel, JL
    [J]. WATER SCIENCE AND TECHNOLOGY, 2000, 42 (10-11) : 237 - 246
  • [6] Parameters affecting hydraulic behavior of aerated lagoons
    Delatolla, RA
    Babarutsi, S
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2005, 131 (10) : 1404 - 1413
  • [7] Semi-empirical methods for determining the efflux velocity from a ship's propeller
    Lam, W.
    Hamill, G. A.
    Robinson, D. J.
    Raghunathan, S.
    [J]. APPLIED OCEAN RESEARCH, 2012, 35 : 14 - 24
  • [8] A review of the equations used to predict the velocity distribution within a ship's propeller jet
    Lam, W.
    Hamil, G. A.
    Song, Y. C.
    Robinson, D. J.
    Raghunathan, S.
    [J]. OCEAN ENGINEERING, 2011, 38 (01) : 1 - 10
  • [9] Levenspiel O., 1979, CHEM REACTION ENG, V3rd
  • [10] Maynord S.T., 1990, VELOCITIES INDUCED C, P137