Thermal comfort in residential buildings - Failure to predict by Standard model

被引:115
作者
Becker, R. [1 ]
Paciuk, M. [2 ]
机构
[1] Technion Israel Inst Technol, Fac Civil & Environm Engn, IL-32000 Haifa, Israel
[2] Technion Israel Inst Technol, Natl Bldg Res Inst, IL-32000 Haifa, Israel
关键词
Thermal sensation; Thermal comfort; Predicted mean vote; Dwellings; Field survey; PMV;
D O I
10.1016/j.buildenv.2008.06.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A field study, conducted in 189 dwellings in winter and 205 dwellings in summer, included measurement of hygro-thermal conditions and documentation of occupant responses and behavior patterns. Both samples included both passive and actively space-conditioned dwellings. Predicted mean votes (PMV) computed using Fanger's model yielded significantly lower-than-reported thermal sensation (TS) values, especially for the winter heated and summer air-conditioned groups. The basic model assumption of a proportional relationship between thermal response and thermal load proved to be inadequate. with actual thermal comfort achieved at substantially lower loads than predicted. Survey results also refuted the model's second assumption that symmetrical responses in the negative and positive directions of the scale represent similar comfort levels. Results showed that the model's curve of predicted percentage of dissatisfied (PPD) substantially overestimated the actual percentage of dissatisfied within the partial group of respondents who voted TS > 0 in winter as well as within the partial group of respondents who voted TS < 0 in summer. Analyses of sensitivity to possible survey-related inaccuracy factors (metabolic rate, clothing thermal resistance) did not explain the systematic discrepancies. These discrepancies highlight the role of contextual variables (local climate, expectations, available control) in thermal adaptation in actual settings. Collected data was analyzed statistically to establish baseline data for local standardized thermal and energy calculations. A 90% satisfaction criterion yielded 19.5 degrees C and 26 degrees C as limit values for passive winter and summer design conditions, respectively, while during active conditioning periods, set-point temperatures of 21.5 degrees C and 23 degrees C should be assumed for winter and summer, respectively. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:948 / 960
页数:13
相关论文
共 11 条
  • [1] [Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
  • [2] [Anonymous], 2013, ASHRAE Stand
  • [3] An adaptive thermal comfort model for the Tunisian context: a field study results
    Bouden, C
    Ghrab, N
    [J]. ENERGY AND BUILDINGS, 2005, 37 (09) : 952 - 963
  • [4] *CENTR BUR STAT, 2001, STAT ABSTR ISR 52
  • [5] THERMAL COMFORT IN THE HUMID TROPICS - FIELD EXPERIMENTS IN AIR-CONDITIONED AND NATURALLY VENTILATED BUILDINGS IN SINGAPORE
    DEDEAR, RJ
    LEOW, KG
    FOO, SC
    [J]. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1991, 34 (04) : 259 - 265
  • [6] Fanger PO, 2002, ENERG BUILDINGS, V34, P533
  • [7] Fanger PO, 1970, THERMAL COMFORT
  • [8] Thermal comfort for naturally ventilated houses in Indonesia
    Feriadi, H
    Wong, NH
    [J]. ENERGY AND BUILDINGS, 2004, 36 (07) : 614 - 626
  • [9] Humphreys M.A., 1994, THERMAL COMFORT PRES
  • [10] The validity of ISO-PMV for predicting comfort votes in every-day thermal environments
    Humphreys, MA
    Nicol, JF
    [J]. ENERGY AND BUILDINGS, 2002, 34 (06) : 667 - 684