Direct Determination of Urinary Creatinine by Reactive-Thermal Desorption-Extractive Electrospray-Ion Mobility-Tandem Mass Spectrometry.

被引:23
作者
Devenport, Neil A. [1 ]
Blenkhorn, Daniel J. [1 ]
Weston, Daniel J. [2 ]
Reynolds, James C. [1 ]
Creaser, Colin S. [1 ]
机构
[1] Univ Loughborough, Dept Chem, Ctr Analyt Sci, Loughborough LE11 3TU, Leics, England
[2] AstraZeneca R&D, DMPK Innovat Med, Oncol iMed, Alderley Pk SK10 4TG, Cheshire, England
基金
英国生物技术与生命科学研究理事会;
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; DERIVATIZATION; BIOMARKERS; METABOLOMICS;
D O I
10.1021/ac403133t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct, ambient ionization method has been developed for the determination of creatinine in urine that combines derivatization and thermal desorption with extractive electrospray ionization and ion mobility-mass spectrometry. The volatility of creatinine was enhanced by a rapid on-probe aqueous acylation reaction, using a custom-made thermal desorption probe, allowing thermal desorption and ionization of the monoacylated derivative. The monoacyl creatinine [M + H](+) ion (m/z 156) was subjected to mass-to-charge selection and collision induced dissociation to remove the acyl group, generating the protonated creatinine [M + H](+) product ion at m/z 114 before an ion mobility separation was applied to reduce chemical noise. Stable isotope dilution using creatinine-d(3) as internal standard was used for quantitative measurements. The direct on-probe derivatization allows high sample throughput with a typical cycle time of 1 min per sample. The method shows good linearity (R-2 = 0.986) and repeatability (%RSD 8-10%) in the range of 0.25-2.0 mg/mL. The creatinine concentrations in diluted urine samples from a healthy individual were determined to contain a mean concentration of 1.44 mg/mL creatinine with a precision (%RSD) of 9.9%. The reactive ambient ionization approach demonstrated here has potential for the determination of involatile analytes in urine and other biofluids.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 27 条
  • [11] Direct extraction of urinary analytes from undeveloped reversed-phase thin layer chromatography plates using a solvent gradient combined with on-line electrospray ionisation ion mobility-mass spectrometry
    Devenport, Neil A.
    Reynolds, James C.
    Weston, Daniel J.
    Wilson, Ian D.
    Creaser, Colin S.
    [J]. ANALYST, 2012, 137 (15) : 3510 - 3513
  • [12] Determination of free desmosine and isodesmosine as urinary biomarkers of lung disorder using ultra performance liquid chromatography-ion mobility-mass spectrometry
    Devenport, Neil A.
    Reynolds, James C.
    Parkash, Ved
    Cook, Jason
    Weston, Daniel J.
    Creaser, Colin S.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32): : 3797 - 3801
  • [13] Hall BJ, 1999, J FORENSIC SCI, V44, P527
  • [14] Urine Metabolomics Analysis for Kidney Cancer Detection and Biomarker Discovery
    Kim, Kyoungmi
    Aronov, Pavel
    Zakharkin, Stanislav O.
    Anderson, Danielle
    Perroud, Bertrand
    Thompson, Ian M.
    Weiss, Robert H.
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2009, 8 (03) : 558 - 570
  • [15] Knapp DR., 1979, Handbook of Analytical Derivatization Reactions
  • [16] Direct quantification of creatinine in human urine by using isotope dilution extractive electrospray ionization tandem mass spectrometry
    Li, Xue
    Fang, Xiaowei
    Yu, Zhiqiang
    Sheng, Guoying
    Wu, Minghong
    Fu, Jiamo
    Chen, Huanwen
    [J]. ANALYTICA CHIMICA ACTA, 2012, 748 : 53 - 57
  • [17] Detection of Chronic Kidney Disease With Creatinine, Cystatin C, and Urine Albumin-to-Creatinine Ratio and Association With Progression to End-Stage Renal Disease and Mortality
    Peralta, Carmen A.
    Shlipak, Michael G.
    Judd, Suzanne
    Cushman, Mary
    McClellan, William
    Zakai, Neil A.
    Safford, Monika M.
    Zhang, Xiao
    Muntner, Paul
    Warnock, David
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2011, 305 (15): : 1545 - 1552
  • [18] An investigation of the mobility separation of some peptide and protein ions using a new hybrid quadrupole/travelling wave IMS/oa-ToF instrument
    Pringle, Steven D.
    Giles, Kevin
    Wildgoose, Jason L.
    Williams, Jonathan P.
    Slade, Susan E.
    Thalassinos, Konstantinos
    Bateman, Robert H.
    Bowers, Michael T.
    Scrivens, James H.
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 261 (01) : 1 - 12
  • [19] Analytical methods for quantifying creatinine within biological media
    Randviir, Edward P.
    Banks, Craig E.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 239 - 252
  • [20] Head-space analysis in modern gas chromatography
    Snow, NH
    Slack, GC
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (9-10) : 608 - 617