Low-kilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose

被引:299
作者
Sigal-Cinqualbre, AB
Hennequin, R
Abada, HT
Chen, X
Paul, JF
机构
[1] Hop Marie Lannelongue, Dept Radiol, CT Unit, F-92350 Le Plessis Robinson, France
[2] Hop Rene Dubos, Dept Intervent Radiol, Cergy Pontoise, France
[3] Siemens Med Solut, Dept CT Phys & Applicat, Forchheim, Germany
关键词
computed tomography (CT); multi-detector row; radiation exposure; dosimetry; thorax; CT;
D O I
10.1148/radiol.2311030191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the feasibility of low-kilovoltage (ie, 80-kV) chest computed tomography (CT) protocols for adults and the effect of such protocols on image quality and iodine dose. MATERIALS AND METHODS: Preliminarily, 90 patients (30 women, 60 men; mean age, 59 years) requiring contrast material-enhanced chest CT were randomly assigned to one of three protocol groups: protocol A, with use of 80 kV and 135 mAs; protocol B, with use of 80 kV and 180 mAs; or the standard protocol, with use of 120 kV and 90 mAs. Contrast material injection protocols were standardized in all groups. Image noise was calculated and plotted against patient weight. Subsequently, another 52 consecutive patients (11 women, 41 men; mean age, 57 years) were assigned to one of the protocols according to their weight: Patients weighing less than 60 kg were assigned to protocol A; patients weighing 60-75 kg, to protocol B; and patients weighing more than 75 kg, to the standard protocol. Two readers evaluated the CT images qualitatively by using a five-point scale. Statistical analyses were performed by using analysis of variance, kappa, and Fisher exact tests. RESULTS: In the preliminary study, the mean image noise values with protocols A (24 HU) and B (20 HU) were significantly higher (P < .001) than that with the standard protocol (12 HU). With protocols A and B, in the patients weighing more than 60 kg and more than 75 kg, respectively, the noise increased exponentially with patient weight. In the subsequent study, qualitative analysis revealed no significant difference between the low-kilovoltage examinations and the standard examination. Compared with use of the standard protocol, use of protocols A and B resulted in the iodine-based contrast material dose being reduced by 54% and 39%, respectively. CONCLUSION: Weight-adapted low-kilovoltage contrast-enhanced chest CT examinations can be routinely performed with 80 W. Use of these protocols results in good diagnostic image quality and makes it possible to reduce contrast material use by more than 50%. (C) RSNA 2004.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 17 条
[1]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[2]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[3]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[4]  
Galanski M, 2002, RAD EXPOSURE COMPUTE, P1
[5]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[6]   An approach for the estimation of effective radiation dose at CT in pediatric patients [J].
Huda, W ;
Atherton, JV ;
Ware, DE ;
Cumming, WA .
RADIOLOGY, 1997, 203 (02) :417-422
[7]   Dosimetry for low-dose computed tomography of the chest [J].
Lenzen, H ;
Roos, N ;
Diederich, S ;
Meier, N .
RADIOLOGE, 1996, 36 (06) :483-488
[8]   Low-dose high-resolution CT of the chest in children and young adults:: Dose, cooperation, artifact incidence, and image quality [J].
Lucaya, J ;
Piqueras, J ;
García-Peña, P ;
Enríquez, G ;
García-Macías, M ;
Sotil, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) :985-992
[9]   Helical CT of the body: Are settings adjusted for pediatric patients? [J].
Paterson, A ;
Frush, DP ;
Donnelly, LF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :297-301
[10]   Standard-dose and 50%-reduced-dose chest CT: Comparing the effect on image quality [J].
Prasad, SR ;
Wittram, C ;
Shepard, JA ;
McLoud, T ;
Rhea, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (02) :461-465