EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

被引:222
|
作者
Verberne, Hein J. [1 ]
Acampa, Wanda [2 ]
Anagnostopoulos, Constantinos [3 ]
Ballinger, Jim [4 ]
Bengel, Frank [5 ]
De Bondt, Pieter [6 ]
Buechel, Ronny R. [7 ]
Cuocolo, Alberto [8 ]
van Eck-Smit, Berthe L. F. [1 ]
Flotats, Albert [9 ]
Hacker, Marcus [10 ]
Hindorf, Cecilia [11 ]
Kaufmann, Philip A. [7 ]
Lindner, Oliver [12 ]
Ljungberg, Michael [13 ]
Lonsdale, Markus [14 ]
Manrique, Alain [15 ]
Minarik, David [16 ]
Scholte, Arthur J. H. A. [17 ]
Slart, Riemer H. J. A. [18 ]
Tragardh, Elin [19 ,20 ]
de Wit, Tim C. [1 ]
Hesse, Birger [21 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, NL-1105 AZ Amsterdam, Netherlands
[2] CNR, Inst Biostruct & Bioimaging, Naples, Italy
[3] Acad Athens, Biomed Res Fdn, Ctr Expt Surg Clin & Translat Res, Athens, Greece
[4] Guys Hosp, Guys & St Thomas Trust Fdn, Dept Nucl Med, London SE1 9RT, England
[5] Hannover Med Sch, Dept Nucl Med, Hannover, Germany
[6] Onze Lieve Vrouw Hosp, Dept Nucl Med, Aalst, Belgium
[7] Univ Zurich Hosp, Cardiac Imaging, CH-8091 Zurich, Switzerland
[8] Univ Naples Federico II, Dept Adv Biomed Sci, Naples, Italy
[9] Univ Autonoma Barcelona, Hosp Santa Creu & St Pau, Dept Nucl Med, E-08193 Barcelona, Spain
[10] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Div Nucl Med, Vienna, Austria
[11] Skane Univ Hosp, Dept Radiat Phys, Lund, Sweden
[12] Ruhr Univ Bochum, Univ Hosp, Heart & Diabet Ctr North Rhine Westphalia, Inst Radiol Nucl Med & Mol Imaging, Bad Oeynhausen, Germany
[13] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[14] Bispebjerg Hosp, Dept Clin Physiol & Nucl Med, DK-2400 Copenhagen, Denmark
[15] Caen Univ Hosp, GIP Cyceron, Serv Commun Invest Homme, Dept Nucl Med, Caen, France
[16] Skane Univ Hosp, Radiat Phys, Malmo, Sweden
[17] Leiden Univ, Med Ctr, Dept Cardiol, Leiden, Netherlands
[18] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[19] Skane Univ Hosp, Clin Physiol & Nucl Med, Malmo, Sweden
[20] Lund Univ, Malmo, Sweden
[21] Univ Copenhagen Hosp, Rigshosp, Dept Clin Physiol & Nucl Med & PET, DK-2100 Copenhagen, Denmark
关键词
Guidelines; Myocardial perfusion imaging; Nuclear medicine; Procedures; TOMOGRAPHY CORONARY-ANGIOGRAPHY; EMISSION COMPUTED-TOMOGRAPHY; ATTENUATION CORRECTION; CONTRAST-MEDIA; DIAGNOSTIC PERFORMANCE; ADVERSE-REACTIONS; PROGNOSTIC VALUE; A(2A) AGONIST; HYBRID PET/CT; DOUBLE-BLIND;
D O I
10.1007/s00259-015-3139-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have been made, improving MPI procedures. In this paper, the major changes from the updated 2015 procedural guidelines are highlighted, focusing on the important changes related to new instrumentation with improved image information and the possibility to reduce radiation exposure, which is further discussed in relation to the recent developments of new International Commission on Radiological Protection (ICRP) models. Introduction of the selective coronary vasodilator regadenoson and the use of coronary CT-contrast agents for hybrid imaging with SPECT/CT angiography are other important areas for nuclear cardiology that were not included in the previous guidelines.
引用
收藏
页码:1929 / 1940
页数:12
相关论文
共 50 条
  • [1] EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision
    Verberne, Hein J.
    Acampa, Wanda
    Anagnostopoulos, Constantinos
    Ballinger, Jim
    Bengel, Frank
    De Bondt, Pieter
    Buechel, Ronny R.
    Cuocolo, Alberto
    van Eck-Smit, Berthe L. F.
    Flotats, Albert
    Hacker, Marcus
    Hindorf, Cecilia
    Kaufmann, Philip A.
    Lindner, Oliver
    Ljungberg, Michael
    Lonsdale, Markus
    Manrique, Alain
    Minarik, David
    Scholte, Arthur J. H. A.
    Slart, Riemer H. J. A.
    Tragardh, Elin
    de Wit, Tim C.
    Hesse, Birger
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (12) : 1929 - 1940
  • [2] EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging
    Sciagra, Roberto
    Lubberink, Mark
    Hyafil, Fabien
    Saraste, Antti
    Slart, Riemer H. J. A.
    Agostini, Denis
    Nappi, Carmela
    Georgoulias, Panagiotis
    Bucerius, Jan
    Rischpler, Christoph
    Verberne, Hein J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (04) : 1040 - 1069
  • [3] Hybrid SPECT/CT for Attenuation Correction of Stress Myocardial Perfusion Imaging
    Huang, Rui
    Li, Fanglan
    Zhao, Zhen
    Liu, Bin
    Ou, Xiaohong
    Tian, Rong
    Li, Lin
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (05) : 344 - 349
  • [4] EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
    B. Hesse
    K. Tägil
    A. Cuocolo
    C. Anagnostopoulos
    M. Bardiés
    J. Bax
    F. Bengel
    E. Busemann Sokole
    G. Davies
    M. Dondi
    L. Edenbrandt
    P. Franken
    A. Kjaer
    J. Knuuti
    M. Lassmann
    M. Ljungberg
    C. Marcassa
    P. Y. Marie
    F. McKiddie
    M. O’Connor
    E. Prvulovich
    R. Underwood
    B. van Eck-Smit
    European Journal of Nuclear Medicine and Molecular Imaging, 2005, 32 : 855 - 897
  • [5] Comparison of the Extent and Severity of Myocardial Perfusion Defects Measured by CT Coronary Angiography and SPECT Myocardial Perfusion Imaging
    Tamarappoo, Balaji K.
    Dey, Damini
    Nakazato, Ryo
    Shmilovich, Haim
    Smith, Thomas
    Cheng, Victor Y.
    Thomson, Louise E. J.
    Hayes, Sean W.
    Friedman, John D.
    Germano, Guido
    Slomka, Piotr J.
    Berman, Daniel S.
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (10) : 1010 - 1019
  • [6] Future of Radionuclide Myocardial Perfusion Imaging: Transitioning from SPECT to PET
    Di Carli, Marcelo F.
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64 : 3S - 10S
  • [7] SPECT Versus PET Myocardial Perfusion Imaging in Patients with Equivocal CT
    Singh, Vasvi
    Di Carli, Marcelo F.
    CURRENT CARDIOLOGY REPORTS, 2020, 22 (06)
  • [8] Current Status of Myocardial Perfusion Imaging With New SPECT/CT Cameras
    Piekarski, Eve
    Manrique, Alain
    Rouzet, Francois
    Le Guludec, Dominique
    SEMINARS IN NUCLEAR MEDICINE, 2020, 50 (03) : 219 - 226
  • [9] Effective Dose to Patients from SPECT and CT During Myocardial Perfusion Imaging
    Brindhaban, Ajit
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2020, 48 (02) : 143 - 147
  • [10] Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging
    Hatipoglu, Filiz
    Cetin, Neslihan
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2023, 32 (02) : 138 - 145