Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates

被引:532
作者
Hausleiter, J
Meyer, T
Hadamitzky, M
Huber, E
Zankl, M
Martinoff, S
Kastrati, A
Schömig, A
机构
[1] Klin TU Munchen, Deutsch Herzzentrum, Klin Herz & Kreislauferkrankungen, D-80636 Munich, Germany
[2] Klin TU Munchen, Deutsch Herzzentrum, Inst Radiol & Nuklearmed, D-80636 Munich, Germany
[3] GSF Forschungszentrum Umwelt & Gesundheit, Neuherberg, Germany
关键词
imaging; tomography; angiography;
D O I
10.1161/CIRCULATIONAHA.105.602490
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Multislice computed tomography angiography (CTA) is a promising technology for imaging patients with suspected coronary artery disease. Compared with 16-slice CTA, the improved spatial and temporal resolution of 64-slice CTA (0.6-versus 1.0-mm slice thickness and 330- versus 420-ms gantry rotation time) is associated with an increase in radiation dose. The objective of this retrospective investigation was to compare the estimated dose received during 16- and 64-slice CTA in daily practice and to investigate the impact of different scan protocols on dose and image quality. Methods and Results - Radiation dose was estimated for 1035 patients undergoing coronary CTA. Scanning algorithms with and without an ECG-dependent dose modulation and with a reduced tube voltage were investigated on dose estimates and image quality. In the entire patient cohort, radiation dose estimates were 6.4 +/- 1.9 and 11.0 +/- 4.1 mSv for 16- and 64- slice CTA, respectively (P < 0.01). The reduction in radiation dose estimates ranged between 37% and 40% and between 53% and 64% with the use of ECG-dependent dose modulation and with the combined use of the dose modulation and a reduced tube voltage, respectively. The reduction in dose estimates was not associated with a reduction in diagnostic image quality as assessed by the signal-to-noise ratio and by the frequency of coronary segments with diagnostic image quality. Conclusions - The increase in spatial and temporal resolution with 64- slice CTA is associated with an increased radiation dose for coronary CTA. Dose-saving algorithms are very effective in reducing radiation exposure and should be used whenever possible.
引用
收藏
页码:1305 / 1310
页数:6
相关论文
共 16 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Multi-detector row CT angiography of the brain at various kilovoltage settings [J].
Ertl-Wagner, BB ;
Hoffmann, RT ;
Bruning, R ;
Herrmann, K ;
Snyder, B ;
Blume, JD ;
Reiser, MF .
RADIOLOGY, 2004, 231 (02) :528-535
[5]   Technique factors and image quality as functions of patient weight at abdominal CT [J].
Huda, W ;
Scalzetti, EM ;
Levin, G .
RADIOLOGY, 2000, 217 (02) :430-435
[6]   Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation [J].
Lacomis, JM ;
Wigginton, W ;
Fuhrman, C ;
Schwartzman, D ;
Armfield, DR ;
Pealer, KM .
RADIOGRAPHICS, 2003, 23 :S35-S48
[7]   Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound [J].
Leber, AW ;
Knez, A ;
von Ziegler, F ;
Becker, A ;
Nikolaou, K ;
Paul, S ;
Wintersperger, B ;
Reiser, M ;
Becker, CR ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :147-154
[8]   Performance evaluation of a multi-slice CT system [J].
McCollough, CH ;
Zink, FE .
MEDICAL PHYSICS, 1999, 26 (11) :2223-2230
[9]  
MENZEL HG, 2000, PUBLICATION EUR
[10]   Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography [J].
Mollet, NR ;
Cademartiri, F ;
Krestin, GP ;
McFadden, EP ;
Arampatzis, CA ;
Serruys, PW ;
de Feyter, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (01) :128-132