Amperometric glucose biosensor based on electroconductive hydrogels

被引:29
|
作者
Kotanen, Christian N. [1 ,2 ]
Tlili, Chaker [1 ,3 ]
Guiseppi-Elie, Anthony [1 ,2 ,3 ,4 ,5 ]
机构
[1] Clemson Univ, Ctr Adv Mat, Ctr Bioelect Biosensors & Biochips C3B, Anderson, SC 29625 USA
[2] Clemson Univ, Dept Bioengn, Clemson, SC 29634 USA
[3] Clemson Univ, Dept Chem & Biomol Engn, Clemson, SC 29634 USA
[4] Clemson Univ, Dept Elect & Comp Engn, Clemson, SC 29634 USA
[5] ABTECH Sci Inc, Richmond, VA 23219 USA
关键词
Biofabrication; Biotransducers; Biosensors; Amperometry; Hydrogels; Glucose oxidase; Glucose; Membranes; HEPATIC INSULIN-RESISTANCE; FILM THICKNESS; CHOLESTEROL OXIDASE; POLYPYRROLE FILMS; ELECTRODE ARRAYS; IN-VITRO; ENZYME; IMMOBILIZATION; BIOCOMPATIBILITY; PERFORMANCE;
D O I
10.1016/j.talanta.2012.10.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fabrication of an enzyme amperometric biosensor for glucose via electropolymerization of pyrrole in the presence of glucose oxidase onto a hydrogel coated platinum electrode is hereby established as a viable biotransducer fabrication method. Platinum micro- (phi=25 mu m) and macro- (phi=100 mu m) electrodes were electrochemically activated and chemically modified with 3-aminopropyl-trimethoxysilane (APTMS), functionalized with acryloyl(polyethyleneglycol)-N-hydroxysuccinamide (ACRL-PEG-NHS), dipped into a polyHEMA based hydrogel cocktail and UV cross-linked. Electropolymerization of Py in the presence of GOx produced glucose responsive biotransducers that showed; (i) a 4-fold reduction in sensitivity compared with directly electropolymerized PPy films, (ii) an electropolymerization charge density dependence of biotransducer sensitivity and enzyme activity that was maximal at 1.0 mC/cm(2) with an apparent K-M of 33 mM, (iii) interference screening of ascorbic acid and (iv) a temporal increase in sensitivity with storage over a 17 days period. This method has the ability to precisely and quantitatively add enzyme catalytic bioactivity to metal or semiconductor biointerfaces for applications in biosensors, bioelectronics and bionics. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:228 / 235
页数:8
相关论文
共 50 条
  • [1] Amperometric Glucose Biosensor Based on Carbon Nanoparticles
    Wang Mei-Fang
    Zhang Wei
    Fang Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (01) : 125 - 128
  • [2] An amperometric glucose biosensor based on PEDOT nanofibers
    Cetin, Merih Zeynep
    Camurlu, Pinar
    RSC ADVANCES, 2018, 8 (35): : 19724 - 19731
  • [3] Amperometric glucose biosensor based on lipid film
    Wu, ZY
    Wang, BQ
    Dong, SJ
    Wang, EK
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4): : 143 - 147
  • [4] Amperometric glucose biosensor based on silver nanowires and glucose oxidase
    Wang, Lisha
    Gao, Xia
    Jin, Lingyan
    Wu, Qi
    Chen, Zhichun
    Lin, Xianfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 9 - 14
  • [5] Thermoresponsive amperometric glucose biosensor
    Pinyou, Piyanut
    Ruff, Adrian
    Poeller, Sascha
    Barwe, Stefan
    Nebel, Michaela
    Alburquerque, Natalia Guerrero
    Wischerhoff, Erik
    Laschewsky, Andre
    Schmaderer, Sebastian
    Szeponik, Jan
    Plumere, Nicolas
    Schuhmann, Wolfgang
    BIOINTERPHASES, 2016, 11 (01) : 1 - 7
  • [6] A microflow amperometric glucose biosensor
    Towe, Bruce C.
    Pizziconi, Vincent B.
    Biosensors and Bioelectronics, 1997, 12 (9-10): : 893 - 899
  • [7] AMPEROMETRIC BIOSENSOR FOR GLUCOSE AND LACTATE
    KAISHEVA, A
    ATANASOV, P
    GAMBURZEV, S
    DIMCHEVA, N
    ILIEV, I
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (01) : 53 - 57
  • [8] A microflow amperometric glucose biosensor
    Towe, BC
    Pizziconi, VB
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10): : 893 - 899
  • [9] Novel amperometric glucose biosensor based on MXene nanocomposite
    Rakhi, R. B.
    Nayuk, Pranati
    Xia, Chuan
    Alshareef, Husam N.
    SCIENTIFIC REPORTS, 2016, 6
  • [10] Atn amperometric glucose biosensor
    Podaru, C
    Bostan, C
    Malide, C
    Neagoe, O
    Simion, M
    Popescu, G
    Garganciuc, D
    Tzetcu, N
    CAS '96 PROCEEDINGS - 1996 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 19TH EDITION, VOLS 1 AND 2, 1996, : 101 - 104