The tribology of metal-on-metal total hip replacements

被引:23
作者
Scholes, SC [1 ]
Unsworth, A [1 ]
机构
[1] Univ Durham, Ctr Biomed Engn, Sch Engn, Durham DH1 3LE, England
关键词
total replacement hip joints; metal-on-metal prostheses; friction; lubrication; wear;
D O I
10.1243/09544119JEIM40
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total hip surgery is an effective way of alleviating the pain and discomfort caused by diseased or damaged joints. However, in the majority of cases, these joints have a finite life. The main reason for failure is osteolysis (bone resorption). It is well documented that an important cause of osteolysis, and therefore the subsequent loosening and failure of conventional metal- or ceramic-on-ultra-high molecular weight polyethylene joints, is the body's immunological response to the polyethylene wear particles. To avoid this, interest has been renewed in metal-on-metal joints. The intention of this paper is to review the studies that have taken place within different laboratories to determine the tribological performance of new-generation metal-on-metal total hip replacements. These types of joint offer a potential solution to enhance the longevity of prosthetic hip systems; however, problems may arise owing to the effects of metal ion release, which are, as yet, not fully understood.
引用
收藏
页码:183 / 194
页数:12
相关论文
共 63 条
[1]  
AMSTUTZ HC, 1996, CLIN ORTHOP S, V329, pS11
[2]  
Andersson G B, 1972, J Bone Joint Surg Br, V54, P590
[3]  
[Anonymous], 2002, 1424212002 ISO
[4]   A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :455-467
[5]   Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant [J].
Bigsby, RJA ;
Hardaker, CS ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) :265-269
[6]   Effect of ion implantation on the tribology of metal-on-metal hip prostheses [J].
Bowsher, JG ;
Hussain, A ;
Williams, P ;
Nevelos, J ;
Shelton, JC .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :107-111
[7]  
BOWSHER JG, 2003, 49 ANN M ORTH RES SO
[8]  
BOWSHER JG, 2004, 50 ANN M ORTH RES SO
[9]   Serum cobalt levels after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
Gottsauner-Wolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2168-2173
[10]   Charnley total hip arthroplasty in patients less than fifty years old - A twenty to twenty-five-year follow-up note [J].
Callaghan, JJ ;
Forest, EE ;
Olejniczak, JP ;
Goetz, DD ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :704-714