Volumetric absorptive microsampling (VAMS) as an alternative to conventional dried blood spots in the quantification of miltefosine in dried blood samples

被引:64
|
作者
Kip, A. E. [1 ,2 ]
Kiers, K. C. [1 ]
Rosing, H. [1 ]
Schellens, J. H. M. [2 ,3 ]
Beijnen, J. H. [1 ,2 ,3 ]
Dorlo, T. P. C. [2 ,4 ]
机构
[1] Slotervaart Hosp, Antoni van Leeuwenhoek Hosp, Dept Pharm & Pharmacol, POB 90440, NL-1006 BK Amsterdam, Netherlands
[2] Univ Utrecht, Fac Sci, Utrecht Inst Pharmaceut Sci, Div Pharmacoepidemiol & Clin Pharmacol, Univ Weg 99, NL-3584 CG Utrecht, Netherlands
[3] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Clin Pharmacol, POB 90203, NL-1006 BE Amsterdam, Netherlands
[4] Uppsala Univ, Pharmacometr Res Grp, Dept Pharmaceut Biosci, Box 570, S-75123 Uppsala, Sweden
关键词
Miltefosine; Volumetric absorptive microsampling (VAMS); Hematocrit; Dried blood; Bioanalysis; LC-MS/MS; QUANTITATIVE BIOANALYSIS; VISCERAL LEISHMANIASIS; WHOLE-BLOOD; ASSAY BIAS; LC-MS/MS; HEMATOCRIT; VALIDATION; DBS; COLLECTION; RECOVERY;
D O I
10.1016/j.jpba.2016.12.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Miltefosine is an oral agent against the neglected tropical disease leishmaniasis, which is mostly endemic in resource-poor areas. Dried blood spot (DBS) sampling is an attractive alternative to plasma sampling for pharmacokinetic studies in these remote areas, but introduces additional variability in analyte quantification due to possible blood spot inhomogeneity and variability in blood spot volume and haematocrit values. Volumetric absorptive microsampling (VAMS) potentially overcomes a few of these issues as the VAMS device absorbs a fixed volume that is processed as a whole. We developed and validated an LC-MS/MS method for the quantification of miltefosine with this novel sampling technique with good performance in terms of linearity, selectivity, accuracy (bias within +/- 10.8%), precision (CV% <= 11.9%), recovery, carry-over and matrix effect. VAMS samples were stable for at least one month at room temperature and 37 degrees C. The impact of haematocrit on assay accuracy was reduced compared to conventional DBS sampling, but indicated a declining recovery with increased haematocrit due to haematocrit dependency in recovery from the sampling device. A clinical validation will be required to investigate whether VAMS is an appropriate and cost-effective alternative sampling method to conventional DBS sampling. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:160 / 166
页数:7
相关论文
共 50 条
  • [11] Analytical and clinical validation of dried blood spot and volumetric absorptive microsampling for measurement of tacrolimus and creatinine after renal transplantation
    Mathew, Binu Susan
    Mathew, Sumith K.
    Aruldhas, Blessed Winston
    Prabha, Ratna
    Gangadharan, Naveen
    David, Vinoi George
    Varughese, Santosh
    John, George Tharayil
    CLINICAL BIOCHEMISTRY, 2022, 105 : 25 - 34
  • [12] Volumetric absorptive microsampling-LC-MS/MS assays for quantitation of giredestrant in dried human whole blood
    Johnson, Ryan
    Rehmani, Imran
    Leahy, Mark
    Walker, Abigail
    Liang, Xiaorong
    Dean, Brian
    Wang, Jianshuang
    BIOANALYSIS, 2022, 14 (21) : 1377 - 1389
  • [13] Analysis of tamoxifen and its metabolites in dried blood spot and volumetric absorptive microsampling: comparison and clinical application
    Maggadani, Baitha Palanggatan
    Harahap, Yahdiana
    Harmita
    Haryono, Samuel J.
    Untu, Christoffel William Putra
    HELIYON, 2021, 7 (06)
  • [14] Analytical and Clinical Validation of Assays for Volumetric Absorptive Microsampling (VAMS) of Drugs in Different Blood Matrices: A Literature Review
    Nugraha, Rhea Veda
    Yunivita, Vycke
    Santoso, Prayudi
    Hasanah, Aliya Nur
    Aarnoutse, Rob E.
    Ruslami, Rovina
    MOLECULES, 2023, 28 (16):
  • [15] Application of volumetric absorptive microsampling device for quantification of tacrolimus in human blood as a model drug of high blood cell partition
    Kita, Kenji
    Mano, Yuji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 143 : 168 - 175
  • [16] Perforated dried blood spots: a novel format for accurate microsampling
    Li, Fumin
    Zulkoski, John
    Fast, Douglas
    Michael, Steve
    BIOANALYSIS, 2011, 3 (20) : 2321 - 2333
  • [17] Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis
    Denniff, Philip
    Spooner, Neil
    ANALYTICAL CHEMISTRY, 2014, 86 (16) : 8489 - 8495
  • [18] Volumetric absorptive microsampling (VAMS) coupled with high-resolution, accurate-mass (HRAM) mass spectrometry as a simplified alternative to dried blood spot (DBS) analysis for therapeutic drug monitoring of cardiovascular drugs
    Tanna, Sangeeta
    Alalaqi, Ahmed
    Bernieh, Dennis
    Lawson, Graham
    CLINICAL MASS SPECTROMETRY, 2018, 10 : 1 - 8
  • [19] What is next for dried blood spots?
    Ji, Qin C.
    Liu, Guowen
    D'Arienzo, Celia J.
    Olah, Timothy V.
    Arnold, Mark E.
    BIOANALYSIS, 2012, 4 (16) : 2059 - 2065
  • [20] Perforated dried blood spot accurate microsampling: the concept and its applications in toxicokinetic sample collection
    Li, Fumin
    Ploch, Stephen
    Fast, Douglas
    Michael, Steve
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (05): : 655 - 667