Volumetric absorptive microsampling (VAMS) as an alternative to conventional dried blood spots in the quantification of miltefosine in dried blood samples

被引:64
|
作者
Kip, A. E. [1 ,2 ]
Kiers, K. C. [1 ]
Rosing, H. [1 ]
Schellens, J. H. M. [2 ,3 ]
Beijnen, J. H. [1 ,2 ,3 ]
Dorlo, T. P. C. [2 ,4 ]
机构
[1] Slotervaart Hosp, Antoni van Leeuwenhoek Hosp, Dept Pharm & Pharmacol, POB 90440, NL-1006 BK Amsterdam, Netherlands
[2] Univ Utrecht, Fac Sci, Utrecht Inst Pharmaceut Sci, Div Pharmacoepidemiol & Clin Pharmacol, Univ Weg 99, NL-3584 CG Utrecht, Netherlands
[3] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Clin Pharmacol, POB 90203, NL-1006 BE Amsterdam, Netherlands
[4] Uppsala Univ, Pharmacometr Res Grp, Dept Pharmaceut Biosci, Box 570, S-75123 Uppsala, Sweden
关键词
Miltefosine; Volumetric absorptive microsampling (VAMS); Hematocrit; Dried blood; Bioanalysis; LC-MS/MS; QUANTITATIVE BIOANALYSIS; VISCERAL LEISHMANIASIS; WHOLE-BLOOD; ASSAY BIAS; LC-MS/MS; HEMATOCRIT; VALIDATION; DBS; COLLECTION; RECOVERY;
D O I
10.1016/j.jpba.2016.12.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Miltefosine is an oral agent against the neglected tropical disease leishmaniasis, which is mostly endemic in resource-poor areas. Dried blood spot (DBS) sampling is an attractive alternative to plasma sampling for pharmacokinetic studies in these remote areas, but introduces additional variability in analyte quantification due to possible blood spot inhomogeneity and variability in blood spot volume and haematocrit values. Volumetric absorptive microsampling (VAMS) potentially overcomes a few of these issues as the VAMS device absorbs a fixed volume that is processed as a whole. We developed and validated an LC-MS/MS method for the quantification of miltefosine with this novel sampling technique with good performance in terms of linearity, selectivity, accuracy (bias within +/- 10.8%), precision (CV% <= 11.9%), recovery, carry-over and matrix effect. VAMS samples were stable for at least one month at room temperature and 37 degrees C. The impact of haematocrit on assay accuracy was reduced compared to conventional DBS sampling, but indicated a declining recovery with increased haematocrit due to haematocrit dependency in recovery from the sampling device. A clinical validation will be required to investigate whether VAMS is an appropriate and cost-effective alternative sampling method to conventional DBS sampling. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:160 / 166
页数:7
相关论文
共 50 条
  • [1] Comparison of conventional dried blood spots and volumetric absorptive microsampling for tacrolimus and mycophenolic acid determination
    Paniagua-Gonzalez, Lucia
    Lendoiro, Elena
    Otero-Anton, Esteban
    Lopez-Rivadulla, Manuel
    de-Castro-Rios, Ana
    Cruz, Angelines
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 208
  • [2] Capillary blood collected on volumetric absorptive microsampling (VAMS) device for monitoring hydroxychloroquine in rheumatoid arthritis patients
    Qu, Ying
    Brady, Kelley
    Apilado, Robert
    O'Malley, Tyler
    Reddy, Smitha
    Chitkara, Puja
    Ibarra, Claudia
    Alexander, Roberta Vezza
    Dervieux, Thierry
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 140 : 334 - 341
  • [3] Volumetric Absorptive Microsampling (VAMS) technology for IGF-1 quantification by automated chemiluminescent immunoassay in dried blood
    Marchand, A.
    Roulland, I
    Semence, F.
    Audran, M.
    GROWTH HORMONE & IGF RESEARCH, 2020, 50 : 27 - 34
  • [4] Volumetric absorptive microsampling and dried blood spot microsampling vs. conventional venous sampling for tacrolimus trough concentration monitoring
    Veenhof, Herman
    Koster, Remco A.
    Junier, Lenneke A. T.
    Berger, Stefan P.
    Bakker, Stephan J. L.
    Touw, Daan J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (10) : 1687 - 1695
  • [5] Volumetric absorptive microsampling (VAMS) as a reliable tool to assess thiamine status in dried blood microsamples: a comparative study
    Verstraete, Jana
    Stove, Christophe
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2021, 114 (03) : 1200 - 1207
  • [6] Development of LC-MS/MS method for quantification of Lurasidone using volumetric absorptive microsampling (VAMS); a comparative study between dried blood and plasma samples
    Rajadhyaksha, Madhura
    Londhe, Vaishali
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1244
  • [7] Validation and application of volumetric absorptive microsampling (VAMS) dried blood method for phenylalanine measurement in patients with phenylketonuria
    Gao, Lan
    Smith, Neil
    Kaushik, Diksha
    Milner, Sarah
    Kong, Ronald
    CLINICAL BIOCHEMISTRY, 2023, 116 : 65 - 74
  • [8] Automated capillary electrophoresis analyses of dried blood samples after patient-centric volumetric absorptive microsampling
    Marsala, Richard
    Dvorak, Milos
    Kuban, Pavel
    ADVANCES IN SAMPLE PREPARATION, 2025, 13
  • [9] Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study
    De Kesel, Pieter M. M.
    Lambert, Willy E.
    Stove, Christophe P.
    ANALYTICA CHIMICA ACTA, 2015, 881 : 65 - 73
  • [10] Quantification of valproic acid in dried blood spots
    Pohanka, Anton
    Mahindi, Margarita
    Masquelier, Michele
    Gustafsson, Lars L.
    Beck, Olof
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2014, 74 (07) : 648 - 652