Performance of fiber-reinforced plastic tapered poles under lateral loading

被引:23
|
作者
Polyzois, D [1 ]
Ibrahim, S [1 ]
Raftoyiannis, IG [1 ]
机构
[1] Univ Manitoba, Dept Civil & Geol Engn, Winnipeg, MB R3T 5V6, Canada
关键词
composites; tapered; hollow sections; material; buckling; failure;
D O I
10.1177/002199839903301004
中图分类号
TB33 [复合材料];
学科分类号
摘要
An extensive research project is currently being carried out at the University of Manitoba to develop lightweight poles for use in transmission lines. In this project, the failure modes of tapered fiber-reinforced plastic (FRP) poles with hollow circular cross-section subjected to cantilever bending are being investigated experimentally and theoretically. The poles are made of vinylester reinforced with E-glass fibers and are produced by the filament winding process. To date, twelve bending tests have been conducted on scaled poles up to failure. Test parameters included the wind angle, and the number of layers. Local buckling and/or material failure, very likely to appear in thin-wall cross-sections, are also investigated. The analysis was conducted through a nonlinear finite element program using superparametric layered cured shell element. The coupling phenomenon between flexural bending and in-plane stretching and the effect of shear deformation were included in the finite element model. The analytical results obtained in this study are compared to experimental results obtained for various thickness and reinforcement specimens of composite poles. The finite element model was used to design a series of FRP poles with different safety factors.
引用
收藏
页码:941 / 960
页数:20
相关论文
共 50 条
  • [1] Materials Selection and Performance of Fiber-Reinforced Plastic Poles
    Bassyouni, M.
    Elhenawy, Yasser
    Kulikova, Yuliya
    Babich, Olga
    El-Hadek, Medhat A.
    ENGINEERING SOLUTIONS TOWARD SUSTAINABLE DEVELOPMENT, ESSD 2023, 2024, : 687 - 696
  • [2] Ovalization analysis of fiber-reinforced plastic poles
    Ibrahim, S
    Polyzois, D
    COMPOSITE STRUCTURES, 1999, 45 (01) : 7 - 12
  • [3] Finite-element analysis of tapered steel and fiber-reinforced plastic bridge camera poles
    Jung, Jiwon
    Abolmaali, Ali
    Choi, Yeol
    JOURNAL OF BRIDGE ENGINEERING, 2006, 11 (05) : 611 - 617
  • [4] Modeling of Glass Fiber-Reinforced Polymer-Reinforced Squat Walls under Lateral Loading
    Kim, Ju-Hyung
    Kim, Yail J.
    Park, Hong-Gun
    ACI STRUCTURAL JOURNAL, 2024, 121 (03) : 201 - 213
  • [5] LOADING AND UNLOADING OF AN ELASTIC-PLASTIC FIBER-REINFORCED CANTILEVER
    ENGLAND, AH
    ROGERS, TG
    MECHANICS RESEARCH COMMUNICATIONS, 1992, 19 (04) : 333 - 340
  • [7] Ultra-High-Performance Fiber-Reinforced Concrete under Cyclic Loading
    Paschalis, Spyridon A.
    Lampropoulos, Andreas P.
    ACI MATERIALS JOURNAL, 2016, 113 (04) : 419 - 427
  • [8] ON FEATURES OF THE FRACTURE OF FIBER-REINFORCED PLASTIC UNDER COMPRESSION
    KUPERMAN, AM
    BAZHENOV, SL
    ASLANIAN, AA
    BERLIN, AA
    ZELENSKII, ES
    DOKLADY AKADEMII NAUK SSSR, 1988, 298 (06): : 1424 - 1427
  • [9] Behavior of Laminated Timber Portal Frames Reinforced with Fiber-reinforced Plastic Laminates under Cyclic Lateral Load
    Song, Yo-Jin
    Baek, Seong-Yeob
    Kim, Hyun-Woo
    Hong, Soon-Il
    BIORESOURCES, 2024, 19 (04): : 8739 - 8757
  • [10] HYBRID FIBER-REINFORCED CONCRETE UNDER REPEATED LOADING
    KOMLOS, K