The locking attachment plate for proximal fixation of periprosthetic femur fractures-a biomechanical comparison of two techniques

被引:35
作者
Lenz, Mark [1 ]
Windolf, Markus [1 ]
Mueckley, Thomas [2 ]
Hofmann, Gunther O. [2 ]
Wagner, Michael [3 ]
Richards, Robert G. [1 ]
Schwieger, Karsten [1 ]
Gueorguiev, Boyko [1 ]
机构
[1] AO Res Inst Davos, CH-7270 Davos, Switzerland
[2] Univ Jena, Dept Traumatol Hand & Reconstruct Surg, D-07740 Jena, Germany
[3] Wilhelminenspital Stadt Wien, Dept Traumatol, A-1160 Vienna, Austria
关键词
FEMORAL-SHAFT FRACTURES; TOTAL HIP-ARTHROPLASTY; FOLLOW-UP; TIP; STABILIZATION; REPLACEMENT; IMPLANT; STEM;
D O I
10.1007/s00264-012-1574-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Mechanical properties of a locking attachment plate construct (LAP-LCP), allowing bicortical screw placement laterally to the prosthesis stem, are compared to a cerclage-LCP construct. Eight right synthetic femora with implanted uncemented hip endoprosthesis were cut distally and fixed with LCP, monocortical locking screws and either LAP (n = 4) or cerclage (n = 4). Cyclic testing was performed with monotonically increasing sinusoidal load until failure. Relative movements at the plate-femur interface were registered by motion tracking. Statistical differences were detected by unpaired t-test and general linear model repeated measures. Stiffness of the LAP-LCP was significantly higher at the beginning (875.4 N/mm +/- 29.8) and after 5000 cycles (1213.0 N/mm +/- 101.1) compared to the cerclage-LCP (644.96 N/mm +/- 50.1 and 851.9 N/mm +/- 81.9), with p = 0.013. Relative movements for AP-bending (B) and axial translation (T) of the LAP-LCP at the beginning (0.07A degrees A +/- 0.02, 0.20 mm +/- 0.08), after 500 cycles (0.16A degrees A +/- 0.10, 0.26 mm +/- 0.07) and after 5000 cycles (0.26A degrees A +/- 0.11, 0.31 mm +/- 0.07) differed significantly from the cerclage-LCP (beg.: 0.26A degrees A +/- 0.04, 0.28 mm +/- 0.05; 500 cyc: 0.47A degrees A +/- 0.03, 0.53 mm +/- 0.07; 5000 cyc.: 0.63A degrees A +/- 0.18, 0.79 mm +/- 0.13), with B: p = 0.02, T: p = 0.04. Relative movements for medial bending were not significantly different between the two constructs. Cycles to failure (criterion 1 mm axial translation) differed significantly between LAP-LCP (19,519 +/- 1,758) and cerclage-LCP (11,265 +/- 2,472), with p = 0.035. Biomechanically, the LAP-LCP construct improves proximal fixation of periprosthetic fractures compared to the cerclage-LCP construct.
引用
收藏
页码:1915 / 1921
页数:7
相关论文
共 21 条
  • [1] Fixation of periprosthetic femoral shaft fractures: A biomechanical comparison of two techniques
    Dennis, MG
    Simon, JA
    Kummer, FJ
    Koval, KJ
    Di Cesare, PE
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) : 177 - 180
  • [2] Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques
    Dennis, MG
    Simon, JA
    Kummer, FJ
    Koval, KJ
    DiCesare, PE
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (04) : 523 - 528
  • [3] Internal forces and moments in the femur during walking
    Duda, GN
    Schneider, E
    Chao, EYS
    [J]. JOURNAL OF BIOMECHANICS, 1997, 30 (09) : 933 - 941
  • [4] Duncan CP, 1995, AAOS INSTR COURS LEC, V44, P293
  • [5] G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
    Faul, Franz
    Erdfelder, Edgar
    Lang, Albert-Georg
    Buchner, Axel
    [J]. BEHAVIOR RESEARCH METHODS, 2007, 39 (02) : 175 - 191
  • [6] Fixation of periprosthetic femoral shaft fractures associated with cemented femoral stems - A biomechanical comparison of locked plating and conventional cable plates
    Fulkerson, E
    Koval, K
    Preston, CF
    Iesaka, K
    Kummer, FJ
    Egol, KA
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (02) : 89 - 93
  • [7] Effect on Dynamic Mechanical Stability and Interfragmentary Movement of Angle-Stable Locking of Intramedullary Nails in Unstable Distal Tibia Fractures: A Biomechanical Study
    Gueorguiev, Boyko
    Waehnert, Dirk
    Albrecht, Daniel
    Ockert, Ben
    Windolf, Markus
    Schwieger, Karsten
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (02): : 358 - 365
  • [8] Stabilisation of periprosthetic fractures with angular stable internal fixation:: a report of 13 cases
    Kääb, MJ
    Stöckle, U
    Schütz, M
    Stefansky, J
    Perka, C
    Haas, NP
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (02) : 105 - 110
  • [9] Cancellous and cortical morselized allograft in revision total hip replacement: A biomechanical study of implant stability
    Kligman, M
    Rotem, A
    Roffman, M
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (06) : 797 - 802
  • [10] Less invasive stabilisation system (LISS) for the treatment of periprosthetic femoral fractures: A 3-year follow-up
    Kobbe, Philipp
    Klemm, Ralf
    Reilmann, Heinrich
    Hockertz, Thomas J.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (04): : 472 - 479