Prospective randomized and crossover comparison of two apheresis machines for peripheral blood stem cell collection: a multicenter study

被引:13
作者
Ikeda, Kazuhiko [1 ,6 ]
Minakawa, Keiji [1 ]
Muroi, Kazuo [2 ,6 ]
Fujiwara, Shin-ichiro [3 ]
Yamada-Fujiwara, Minami [4 ]
Fujimori, Yoshihiro [5 ,6 ]
Tanosaki, Ryuji [6 ]
Ohto, Hitoshi [1 ,6 ]
机构
[1] Fukushima Med Univ, Dept Blood Transfus & Transplantat Immunol, 1 Hikariga Oka, Fukushima, Fukushima 9601295, Japan
[2] Jichi Med Univ Hosp, Div Cell Transplantat & Transfus, Dept Med, Shimotsuke, Tochigi, Japan
[3] Jichi Med Univ Hosp, Div Hematol, Dept Med, Shimotsuke, Tochigi, Japan
[4] Tohoku Univ Hosp, Div Blood Transfus & Cell Therapy, Sendai, Miyagi, Japan
[5] Hyogo Coll Med, Dept Transfus Med & Cellular Therapy, Nishinomiya, Hyogo, Japan
[6] Japan Soc Transfus Med & Cell Therapy, Cell Therapy Comm, Tokyo, Japan
关键词
PROGENITOR CELLS; HEMATOPOIETIC STEM; SEPARATORS; FLOW; TRANSPLANTATION; PROGRAMS; SPECTRA; SYSTEMS; COUNTS;
D O I
10.1111/trf.13777
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Improving apheresis technology may lead to an efficient and safe peripheral blood stem cell (PBSC) collection. Recently, the Spectra Optia (Optia, Terumo BCT) was introduced as an automated apheresis instrument, but comparisons with other instruments have been few. This is the first randomized multicenter and crossover comparison of the Optia with the automated program of the established apheresis instrument, the Spectra (Spectra-Auto, Terumo BCT). STUDY DESIGN AND METHODS: A total of 233 apheresis procedures performed in 46 autologous patients and 108 allogeneic donors were investigated. Apheresis performed in the first day for all subjects using the Spectra-Auto (n = 79) and the Optia (n = 75) were evaluated as first-day analysis. Seventy-nine subjects, who required another session on the second day, underwent apheresis using the other instrument than the first-day instrument and were compared with each other in a paired crossover analysis. RESULTS: The two instruments processed similar volumes with comparable run times and volumes of acid-citrate-dextrose used. The volumes of collected products were greater in the Optia. Yields of mononuclear cells and CD34+ cells were not different, but collection efficiencies were higher in the Optia (p = 0.008 in CE1 of crossover analysis). Spectra-Auto-collected products contained more contaminating red blood cells (RBCs), whereas there was a trend of more contaminating platelets (PLTs) in the Optia-collected products. Slight reductions were noted in the RBC or PLT counts of subjects who underwent apheresis with the Spectra-Auto or the Optia, respectively. CONCLUSION: The Optia is safe and more efficient in the PBSC collection compared with the Spectra-Auto.
引用
收藏
页码:2839 / 2847
页数:9
相关论文
共 50 条
  • [21] Platelet decrease and efficacy of platelet-rich plasma return following peripheral blood stem cell apheresis
    Shima, Takahiro
    Sakoda, Teppei
    Henzan, Tomoko
    Kunisaki, Yuya
    Sugio, Takeshi
    Kamezaki, Kenjiro
    Iwasaki, Hiromi
    Teshima, Takanori
    Maeda, Takahiro
    Akashi, Koichi
    Miyamoto, Toshihiro
    JOURNAL OF CLINICAL APHERESIS, 2021, 36 (05) : 687 - 696
  • [22] Efficacy and Safety of Peripheral Blood Stem Cell Collection in Elderly Donors; Does Age Interfere?
    Lysak, Daniel
    Koristek, Zdenek
    Gasova, Zdenka
    Skoumalova, Iva
    Jindra, Pavel
    JOURNAL OF CLINICAL APHERESIS, 2011, 26 (01) : 9 - 16
  • [23] Multicenter study to evaluate a new enumeration method for hematopoietic stem cell collection management
    Gromme, Monique
    Russcher, Henk
    Braakman, Eric
    Klinkspoor, J. Henriette
    Dobber, Johan A.
    de Greef, Inge
    de Wit, Norbert C. J.
    TRANSFUSION, 2017, 57 (08) : 1949 - 1955
  • [24] A comparison of peripheral blood stem cell collection outcomes for multiple myeloma; mobilization matters in the era of IMiD induction
    Chandler, Thea
    Parrish, Christopher
    Karakantza, Marina
    Carmichael, Jonathan
    Pawson, David
    Cook, Gordon
    Seymour, Frances
    EJHAEM, 2023, 4 (03): : 625 - 630
  • [25] Comparison between intermittent and continuous spectra optia leukapheresis systems for autologous peripheral blood stem cell collection
    Lisenko, Katharina
    Pavel, Petra
    Bruckner, Thomas
    Puthenparambil, Joe
    Hundemer, Michael
    Schmitt, Anita
    Witzens-Harig, Mathias
    Ho, Anthony D.
    Wuchter, Patrick
    JOURNAL OF CLINICAL APHERESIS, 2017, 32 (01) : 27 - 34
  • [26] Myeloablative radiochemotherapy followed by autologous peripheral blood stem cell transplantation as first-line therapy in peripheral T-cell lymphomas:: first results of a prospective multicenter study
    Reimer, P
    Schertlin, T
    Rüdiger, T
    Geissinger, E
    Roth, S
    Kunzmann, V
    Weissinger, F
    Nerl, C
    Schmitz, N
    Müller-Hermelink, HK
    Wilhelm, M
    HEMATOLOGY JOURNAL, 2004, 5 (04) : 304 - 311
  • [27] Effects of peripheral blood stem cell apheresis on systemic cytokine levels in patients with multiple myeloma
    Akkok, Cigdem Akalin
    Hervig, Tor
    Stamnesfet, Siren
    Nesthus, Ingerid
    Melve, Guro K.
    Lassalle, Philippe
    Bruserud, Oystein
    CYTOTHERAPY, 2011, 13 (10) : 1259 - 1268
  • [28] Impact of Mobilization Strategies on Peripheral Blood Stem Cell Collection Efficiency and Product Quality: A Retrospective Single-Center Study
    Rajsp, Patricija
    Branka, Manuela
    Besson, Nelly
    Tanzmann, Andreas
    Worel, Nina
    CANCERS, 2022, 14 (24)
  • [29] Predictive factors for successful peripheral blood stem cell mobilization and collection in children
    Truong, Tony H.
    Prokopishyn, Nicole L.
    Luu, Henry
    Guilcher, Gregory M. T.
    Lewis, Victor A.
    JOURNAL OF CLINICAL APHERESIS, 2019, 34 (05) : 598 - 606
  • [30] The impact of preapheresis white blood cell count on autologous peripheral blood stem cell collection efficiency and HSC infusion side effect rate
    Sakashita, Araci. M.
    Kondo, Andrea T.
    Yokoyama, Ana Paula H.
    Lira, Sanny M. C.
    Bub, Carolina B.
    Souza, Aline M.
    Cipolletta, Andrea N. F.
    Alvarez, Kelen C.
    Hamerschlak, Nelson
    Kutner, Jose M.
    Chiattone, Carlos S.
    JOURNAL OF CLINICAL APHERESIS, 2018, 33 (03) : 331 - 341