Repair of orbital floor fractures with bioactive glass implants

被引:74
作者
Aitasalo, K
Kinnunen, I
Palmgren, J
Varpula, M
机构
[1] Turku Univ, Cent Hosp, Dept Otorhinolaryngol Head & Neck Surg, FIN-20521 Turku, Finland
[2] Turku Univ, Cent Hosp, Dept Ophthalmol, FIN-20521 Turku, Finland
[3] Turku Univ, Cent Hosp, Dept Radiol, FIN-20521 Turku, Finland
关键词
D O I
10.1053/joms.2001.27524
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The ideal management of orbital floor fractures has been highly controversial. Many implants, both autogenous and alloplastic, have been used to span the defects. This study evaluated the use of bioactive glass implants (BAG-implant, S53P4; Abmin Technologies Ltd, Turku, Finland) for the repair of orbital floor defects caused by blunt facial trauma. Patients and Methods: This retrospective review of 36 patients was carried out from 1995 to 1999. All patients were diagnosed with an orbital floor fracture or a large orbital blowout fracture. The BAG-implant was placed over the defect, using a subciliary or transconjunctival approach. No screw fixation was used when the implant was the correct size. Follow-up examination was done at I and 3 months after surgery. Twenty-eight (82%) of the patients were also seen at one-year follow-up (21 men and 7 women). Results: The implants did not cause a foreign body reaction in the bone or soft tissue. There was no sign of resorption or infection, nor postoperative extrusion, hemorrhage, or displacement of the implant. Diplopia was seen preoperatively in 17 cases (61%) and postoperatively in 5 cases (18%). In 1 patient, the implant was removed 3 months after operation because of diplopia. Infraorbital nerve paresthesia was seen preoperatively in 9 patients (32%) and postoperatively in 5 patients (18%). The functional and cosmetic results were good at the 1-year follow-up. Conclusion: The BAG-implant is a well-tolerated material in orbital floor reconstruction. It provides a favorable environment for an uncomplicated healing process because it is bioactive and biocompatible and because it causes new bone formation. (C) 2001 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1390 / 1395
页数:6
相关论文
共 50 条
[41]   FRACTURES OF THE ORBITAL FLOOR [J].
SMITH, HW .
BULLETIN OF THE NEW YORK ACADEMY OF MEDICINE, 1979, 55 (08) :733-743
[42]   FRACTURES OF ORBITAL FLOOR [J].
VANGARSSELYSENS, A ;
WATILLON, M .
ANNALES D OCULISTIQUE, 1975, 208 (04) :327-327
[43]   ORBITAL FLOOR FRACTURES [J].
PUTTERMAN, AM .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1975, 101 (11) :706-707
[44]   ORBITAL FLOOR FRACTURES [J].
KOPF, GM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (05) :692-693
[45]   FRACTURES OF THE ORBITAL FLOOR [J].
DEVOE, AG .
TRANSACTIONS OF THE AMERICAN OPHTHALMOLOGICAL SOCIETY, 1947, 45 :502-+
[46]   FRACTURES OF THE ORBITAL FLOOR [J].
DEVOE, AG .
ARCHIVES OF OPHTHALMOLOGY, 1948, 39 (05) :595-622
[47]   FRACTURES OF ORBITAL FLOOR [J].
CRUMLEY, RL ;
LEIBSOHN, J ;
KRAUSE, CJ ;
BURTON, TC .
LARYNGOSCOPE, 1977, 87 (06) :934-947
[48]   Orbital floor repair using medpor porous polyethylene implants. [J].
Lupi, E ;
Messi, M ;
Ascani, G ;
Balercia, P .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 :U504-U504
[49]   Endoscopic transantral and transnasal repair of orbital floor fracture with the ballooning technique, and classification and characterization of orbital floor fractures [J].
Park, Il-Ho ;
Lee, Heung-Man ;
Yanagi, Kiyoshi .
AMERICAN JOURNAL OF RHINOLOGY & ALLERGY, 2015, 29 (06) :445-448
[50]   Bioactive glass granules and polytetrafluoroethylene membrane in the repair of bone defects adjacent to titanium and bioactive glass implants [J].
T. Turunen ;
J. Peltola ;
T. Makkonen ;
H. Helenius ;
A. Yli-Urpo .
Journal of Materials Science: Materials in Medicine, 1998, 9 :403-407