Results on aging of cellulose paper under selective conditions

被引:16
作者
Fofana, I [1 ]
Borsi, H [1 ]
Gockenbach, E [1 ]
机构
[1] Univ Quebec Chicoutimi, Res Grp Atmospher Icing, Chicoutimi, PQ, Canada
来源
2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA | 2001年
关键词
D O I
10.1109/CEIDP.2001.963521
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The aim of this paper is regarded as a main task to study the parameters that mostly influence life time of high voltage transformers. It is shown that the initial moisture content of cellulose paper has a decisive role in the degradation rate of this later, the higher the initial humidity, accelerates very strongly the degradation. The presence of oxygen however markedly increases the degradation rate. The influence of oxygen and moisture on the aging process of this solid insulation have been separately investigated. Their influences seem to be of the same dimension order. The presence of metallic catalysts accelerates the aging process of the cellulose papers too.
引用
收藏
页码:205 / 208
页数:4
相关论文
共 7 条
[1]  
BREEN G, 1992, CIGRE SESS AUG 30 SE
[2]  
CJAERDE AC, 1997, IEEE ELEC INSUL MAG, V13
[3]   Retrofilling conditions of high-voltage transformers [J].
Fofana, I ;
Wasserberg, V ;
Borsi, H ;
Gockenbach, E .
IEEE ELECTRICAL INSULATION MAGAZINE, 2001, 17 (02) :17-30
[4]  
*IEEE WORK GROUP 0, 1993, ELECTRA, P39
[5]  
MOSER HP, 1987, CIGRE S VIENN AUSTR
[6]   Mineral insulating oil in transformers [J].
Rouse, TO .
IEEE ELECTRICAL INSULATION MAGAZINE, 1998, 14 (03) :6-16
[7]  