Biomechanical assessment of a novel tendon junction

被引:10
作者
Crook, T. [1 ]
Tawfik, J. [1 ]
Bertollo, N. [2 ]
Wheen, D. J. [1 ]
Scougall, P. J. [1 ]
Walsh, W. R. [2 ]
机构
[1] St Lukes Hosp, Sydney Hand Clin, Sydney, NSW, Australia
[2] Univ New S Wales, Surg & Orthopaed Res Labs, Prince Wales Clin Sch, Sydney, NSW 2031, Australia
关键词
Tendon weave; Pulvertaft weave; mechanical testing; SPIRAL LINKING TECHNIQUE; PULVERTAFT WEAVE; FLEXOR TENDONS; TENSILE-STRENGTH; REPAIR; SUTURE; FINGERS; GRAFTS;
D O I
10.1177/1753193412465233
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Pulvertaft weave has been the standard tendon junction technique used both in tendon transfers and tendon grafts. A limitation of this repair is the sequential failure of stabilizing sutures, rather than the tendon. A novel loop weave is described and compared with the Pulvertaft weave in biomechanical performance. Ovine deep flexor and extensor tendons were used to simulate Pulvertaft or loop weaves (n = 11) for tensile testing. The Pulvertaft weaves failed at the stabilizing sutures, whereas the loop weaves repairs failed by longitudinal splitting of the motor tendon. The loop weave demonstrated significantly higher mean initial failure and ultimate strengths. Tensile loads required to elongate the loop weave by 4, 6, and 8 mm were significantly higher, while more displacement was associated with the Pulvertaft repair under the application of 50, 75, and 100 N tensile loads. This study demonstrates favourable biomechanical characteristics of the new loop weave technique.
引用
收藏
页码:795 / 800
页数:6
相关论文
共 50 条
  • [41] Collagen Ribbon Augmentation of Achilles Tendon Tears: A Biomechanical Evaluation
    Berlet, Gregory C.
    Hyer, Christopher F.
    Lee, Thomas H.
    Blum, Barbara E.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2014, 53 (03) : 298 - 302
  • [42] The influence of testing angle on the biomechanical properties of the rat supraspinatus tendon
    Newton, Michael D.
    Davidson, Abigail A.
    Pomajzl, Ryan
    Seta, Joseph
    Kurdziel, Michael D.
    Maerz, Tristan
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 4159 - 4163
  • [43] MRI Assessment of Degeneration of the Tendon in Achilles Tendon Ruptures
    Backer, Henrik C.
    Wong, Tony T.
    Vosseller, J. Turner
    [J]. FOOT & ANKLE INTERNATIONAL, 2019, 40 (08) : 895 - 899
  • [44] Primary Tendon Sheath Enlargement and Reconstruction in Zone 2: An In Vitro Biomechanical Study on Tendon Gliding Resistance
    Bunata, Robert E.
    Kosmopoulos, Victor
    Simmons, Sara
    Tayag, Tristan J.
    Roso, Matthew
    Carlson, Heather
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (08): : 1436 - 1443
  • [45] Augmentation of Distal Biceps Tendon Ruptures With the Lacertus Fibrosus: A Biomechanical Study in a Tendon-Deficient Model
    LeVasseur, Matthew R.
    Cusano, Antonio
    Mancini, Michael R.
    Uyeki, Colin L.
    Pina, Matthew J.
    Obopilwe, Elifho
    Caputo, Andrew E.
    Mazzocca, Augustus D.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (03) : 725 - 730
  • [46] Simulating Tendon Shortening During Flexor Tendon Repair Surgery Using A Biomechanical Model and Robotic Testbed
    Tigue, James A.
    Rockwell, W. Bradford
    Foreman, K. Bo
    Mascaro, Stephen
    [J]. 2020 8TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE FOR BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2020, : 193 - 198
  • [47] Rotator cuff repair with periosteum for enhancing tendon-bone healing: a biomechanical and histological study in rabbits
    Chang, Chih-Hsiang
    Chen, Chih-Hwa
    Su, Chun-Yi
    Liu, Hsien-Tao
    Yu, Chung-Ming
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (12) : 1447 - 1453
  • [48] Biomechanical comparison of modified Lim/Tsai tendon repairs with intra- and extra-tendinous knots
    Chang, Min Kai
    Wong, Yoke Rung
    Tay, Shian Chao
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) : 919 - 924
  • [49] Reinforced lengthening Achilles tendon Z-plasty - ex vivo assessment of biomechanical augmentation with surgical-fiberlock technology
    Dreher, Thomas
    Moehl, Andrea
    Bachmann, Elias
    Nieuwland, Arend
    Snedeker, Jess G.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2025, : 1055 - 1063
  • [50] A novel repair method for the treatment of acute Achilles tendon rupture with minimally invasive approach using button implant: A biomechanical study
    Huri, Gazi
    Bicer, Omer Sunkar
    Ozgozen, Levent
    Ucar, Yurdanur
    Garbis, Nickolas G.
    Hyun, Yoon Suk
    [J]. FOOT AND ANKLE SURGERY, 2013, 19 (04) : 261 - 266