Computer-aided gastrointestinal hemorrhage detection in wireless capsule endoscopy videos

被引:87
|
作者
Hassan, Ahnaf Rashilz [1 ]
Haque, Mohammad Ariful [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka 1205, Bangladesh
关键词
Wireless capsule endoscopy (WCE); Bleeding detection; Support vector machine; Normalized Gray Level; Co-Occurrence Matrix; TEXTURAL FEATURES; RECOGNITION;
D O I
10.1016/j.cmpb.2015.09.005
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Wireless Capsule Endoscopy (WCE) can image the portions of the human gastrointestinal tract that were previously unreachable for conventional endoscopy examinations. A major drawback of this technology is that a large volume of data are to be analyzed in order to detect a disease which can be time-consuming and burdensome for the clinicians. Consequently, there is a dire need of computer-aided disease detection schemes to assist the clinicians. In this paper, we propose a real-time, computationally efficient and effective computerized bleeding detection technique applicable for WCE technology. Methods: The development of our proposed technique is based on the observation that characteristic patterns appear in the frequency spectrum of the WCE frames due to the presence of bleeding region. Discovering these discriminating patterns, we develop a texture-feature-descriptor-based-algorithm that operates on the Normalized Gray Level Co-occurrence Matrix (NGLCM) of the magnitude spectrum of the images. A new local texture descriptor called difference average that operates on NGLCM is also proposed. We also perform statistical validation of the proposed scheme. Results: The proposed algorithm was evaluated using a publicly available WCE database. The training set consisted of 600 bleeding and 600 non-bleeding frames. This set was used to train the SVM classifier. On the other hand, 860 bleeding and 860 non-bleeding images were selected from the rest of the extracted images to form the test set. The accuracy, sensitivity and specificity obtained from our method are 99.19%, 99.41% and 98.95% respectively which are significantly higher than state-of-the-art methods. In addition, the low computational cost of our method makes it suitable for real-time implementation. Conclusion: This work proposes a bleeding detection algorithm that employs textural features from the magnitude spectrum of the WCE images. Experimental outcomes backed by statistical validations prove that the proposed algorithm is superior to the existing ones in terms of accuracy, sensitivity, specificity and computational cost. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:341 / 353
页数:13
相关论文
共 50 条
  • [1] Computer-aided diagnosis system for ulcer detection in wireless capsule endoscopy videos
    Charfi, Said
    El Ansari, Mohamed
    2017 3RD INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP), 2017, : 134 - 138
  • [2] Computer-Aided System for Polyp Detection in Wireless Capsule Endoscopy Images
    El Ansari, Mohamed
    Charfi, Said
    2017 INTERNATIONAL CONFERENCE ON WIRELESS NETWORKS AND MOBILE COMMUNICATIONS (WINCOM), 2017, : 407 - 412
  • [3] Computer-aided diagnosis system for ulcer detection in wireless capsule endoscopy images
    Charfi, Said
    El Ansari, Mohamed
    Balasingham, Ilangko
    IET IMAGE PROCESSING, 2019, 13 (06) : 1023 - 1030
  • [4] Computer-aided detection of small intestinal ulcer and erosion in wireless capsule endoscopy images
    Fan, Shanhui
    Xu, Lanmeng
    Fan, Yihong
    Wei, Kaihua
    Li, Lihua
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (16):
  • [5] Computer-aided diagnosis system for colon abnormalities detection in wireless capsule endoscopy images
    Charfi, Said
    El Ansari, Mohamed
    MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (03) : 4047 - 4064
  • [6] Computer-aided diagnosis system for colon abnormalities detection in wireless capsule endoscopy images
    Said Charfi
    Mohamed El Ansari
    Multimedia Tools and Applications, 2018, 77 : 4047 - 4064
  • [7] Computer-Aided Detection of Bleeding Regions for Capsule Endoscopy Images
    Li, Baopu
    Meng, Max Q-H.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (04) : 1032 - 1039
  • [8] Computer-aided small bowel tumor detection for capsule endoscopy
    Li, Baopu
    Meng, Max Q. -H.
    Lau, James Y. W.
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2011, 52 (01) : 11 - 16
  • [9] Computer-Aided Gastrointestinal Diseases Analysis From Wireless Capsule Endoscopy: A Framework of Best Features Selection
    Khan, Muhammad Attique
    Kadry, Seifedine
    Alhaisoni, Majed
    Nam, Yunyoung
    Zhang, Yudong
    Rajinikanth, Venkatesan
    Sarfraz, Muhammad Shahzad
    IEEE ACCESS, 2020, 8 : 132850 - 132859
  • [10] Gastrointestinal Tract Bleeding Detection from Wireless Capsule Endoscopy Videos
    Charfi, Said
    El Ansari, Mohamed
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON INTERNET OF THINGS, DATA AND CLOUD COMPUTING (ICC 2017), 2017,