Evaluation of mist diffusion and application of water tube for dust control in blasting demolition

被引:0
作者
Ko, Young-Hun [1 ]
Park, Hoon [2 ]
Suk, Chul-Gi [3 ]
Yang, Hyung-Sik [1 ]
机构
[1] Chonnam Natl Univ, 77 Yongbong Ro, Gwangju 61186, South Korea
[2] Chonbuk Natl Univ, 567 Baekje Daero, Jeonju Si 54896, Jeollabuk Do, South Korea
[3] Korea Kacoh Co Ltd, 334-1 Digital Ro, Seoul 07448, South Korea
关键词
explosive demolition; dust; detonating cord; water tube; AUTODYN;
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In this study, a water tube with detonating cord has been devised for the effective control of dust during explosive demolition of buildings or structures at construction sites. The AUTODYN program was applied for the numerical analysis and description of the mist diffusion process in the water tube. The analysis results were compared with the experimental results. The dust reduction performance using the water tube was evaluated at a tunnel site in one directional airflow by measuring the total suspended particles, PM10, and PM2.5 of dust and by comparing the application case of the water tube with a non-application case. In conclusion, it was found out in this study that the water tube for the suggested mist diffusion method with a detonating cord has considerable strength. It can be easily installed onsite and a sequential arrangement is allowed. Moreover, the use of the water tube was highly effective in controlling the dust owing to the fine water droplets produced by high-velocity water expansion.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 7 条
  • [1] Han Z., 2009, THESIS, V35
  • [2] Ko Y. H., 2015, 11 INT S ROCK FRAGM, P809
  • [3] Liu F. X., 2011, THESIS
  • [4] Ng D., 1987, COAL DUST GAS EXPLOS, P152
  • [5] Paplinski A., 2009, CENT EUR J ENERG MAT, V6, P291
  • [6] Roman P., 2003, 20 INT C SAF MIN SHE, P3
  • [7] Zheng Li., 2011, PROCEDIA ENG, V11, P258