Effect of Composite Resin and Restorative Technique on Polymerization Shrinkage Stress, Cuspal Strain and Fracture Load of Weakened Premolars

被引:20
作者
Martins, Lais Carvalho [1 ]
Sales Oliveira, Lais Rani [2 ]
Lourenco Braga, Stella Sueli [2 ]
Soares, Carlos Jose [2 ]
Versluis, Antheunis [3 ]
Borges, Gilberto Antonio [1 ]
Verissimo, Crisnicaw [4 ]
机构
[1] Univ Uberaba, Sch Dent, Dept Restorat Dent, Uberaba, MG, Brazil
[2] Univ Fed Uberlandia, Sch Dent, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[3] Univ Tennessee, Hlth Sci Ctr, Dept Biosci Res, Memphis, TN 38163 USA
[4] Univ Fed Goias, Sch Dent, Dept Oral Rehabil, Goiania, Go, Brazil
关键词
biomechanics; cuspal strain; finite element analysis; fracture resistance; shrinkage stress; TREATED MAXILLARY PREMOLARS; BULK-FILL; BIOMECHANICAL BEHAVIOR; RESISTANCE; DEPTH; TEETH; CURE; CONTRACTION; DEFORMATION; DEFLECTION;
D O I
10.3290/j.jad.a45180
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare shrinkage stress, cuspal strain and fracture load of weakened premolars restored with different conventional and bulk-fill composite resins and restorative techniques. Materials and Methods: Fifty premolars received a 4.0 x 3.5mm mesio-occlusal-distal (MOD) class II preparation. The lingual and buccal cups were internally weakened. Specimens were restored according to the following 5 groups: Filtek Z350 XT/10 increments; Filtek Z350 XT/8 increments (both 3M Oral Care); Filtek Bulk Fill Flowable Restorative + Filtek Z350 XT (both 3M Oral Care); SDR + Spectra Basic (Dentsply Sirona); and Tetric N-Ceram Bulk Fill (Ivoclar Vivadent). Cuspal strains were measured using strain gauges (n = 10). After restoration, specimens were submitted to thermal/mechanical cycles and fractured. Post-gel shrinkage of the composites was determined. Additionally, residual shrinkage strains and stresses were analyzed using three-dimensional finite element analysis (3D-FEA). The data were statistically analyzed using one-way ANOVA and Tukey's HSD (alpha = 0.05). Results: One-way ANOVA revealed statistically significant differences among composite resins (p < 0.001) for the post-gel shrinkage. Filtek Z350 XT had the highest post-gel shrinkage and no difference was found between Spectra Basic and Tetric N-Ceram Bulk Fill (p = 0.110). The Filtek Z350 XT/10 increments, Filtek Z350 XT/8 increments and Filtek Bulk Fill Flowable Restorative/Filtek Z350 XT had statistically significantly higher cuspal deformation values when compared to the SDR/Spectra Basic and Tetric N-Ceram Bulk Fill techniques. 3D-FEA confirmed higher stress levels in the incrementally filled conventional restorations. Fracture loads were not statistically significantly different. Conclusion: The bulk-fill restoration techniques resulted in less cuspal strain and stress than the incremental technique with conventional composite resin. Fracture resistance was not affected by the restorative techniques.
引用
收藏
页码:503 / 514
页数:12
相关论文
共 57 条
[1]   Polymerization shrinkage kinetics and shrinkage-stress in dental resin-composites [J].
Al Sunbul, Hanan ;
Silikas, Nick ;
Watts, David C. .
DENTAL MATERIALS, 2016, 32 (08) :998-1006
[2]   Cuspal Deflection of Premolars Restored with Bulk-Fill Composite Resins [J].
Behery, Haytham ;
El-Mowafy, Omar ;
El-Badrawy, Wafa ;
Saleh, Belal ;
Nabih, Sameh .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2016, 28 (02) :122-130
[3]   Bulk-Fill Resin Composites: Polymerization Contraction, Depth of Cure, and Gap Formation [J].
Benetti, A. R. ;
Havndrup-Pedersen, C. ;
Honore, D. ;
Pedersen, M. K. ;
Pallesen, U. .
OPERATIVE DENTISTRY, 2015, 40 (02) :190-200
[4]  
Bicalho A A, 2014, Oper Dent, V39, pE83, DOI 10.2341/12-442-L
[5]  
Bicalho AA., 2014, Operative Dentistry, DOI DOI 10.2341/12-441-L
[6]   Effect of acidic drinks on shade matching, surface topography, and mechanical properties of conventional and bulk-fill composite resins [J].
Borges, Marcela G. ;
Soares, Carlos J. ;
Maia, Thais S. ;
Bicalho, Aline A. ;
Barbosa, Tarsis P. ;
Costa, Henara L. ;
Menezes, Murilo S. .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (05) :868.e1-868.e8
[8]   Factors involved in the development of polymerization shrinkage stress in resin-composites: A systematic review [J].
Braga, RR ;
Ballester, RY ;
Ferracane, JL .
DENTAL MATERIALS, 2005, 21 (10) :962-970
[9]  
BURKE FJT, 1993, OPER DENT, V18, P230
[10]   Bonding Interaction and Shrinkage Stress of Low-viscosity Bulk Fill Resin Composites With High-viscosity Bulk Fill or Conventional Resin Composites [J].
Cerda-Rizo, E. R. ;
Rodrigues, M. de Paula ;
Vilela, A. B. F. ;
Braga, S. S. L. ;
Oliveira, L. R. S. ;
Garcia-Silva, T. C. ;
Soares, C. J. .
OPERATIVE DENTISTRY, 2019, 44 (06) :625-636