The performance study of developed cost-effective Compton Camera based on Ce:GAGG scintillator using experimental measurements and CCMod of GATE simulation module

被引:1
作者
Zarei, Hajar [1 ,2 ]
Nagao, Yuto [1 ,3 ]
Yamamoto, Kohei [1 ]
Itoh, Masatoshi [1 ]
Yamaguchi, Mitsutaka [3 ]
Kawachi, Naoki [3 ]
Watabe, Hiroshi [1 ]
机构
[1] Tohoku Univ, Cyclotron & Radioisotope Ctr, 6-3 Aoba, Aoba ku, Sendai, Miyagi 9808578, Japan
[2] Univ Tehran Med Sci, Adv Med Technol & Instrument Inst, Res Ctr Mol & Cellular Imaging, Tehran, Iran
[3] Natl Inst Quantum Sci & Technol, Takasaki Adv Radiat Res Inst, 1233 Watanuki, Takasaki, Gunma 3701292, Japan
来源
JOURNAL OF INSTRUMENTATION | 2022年 / 17卷 / 10期
基金
日本科学技术振兴机构;
关键词
Compton imaging; Gamma detectors (scintillators; CZT; HPGe; HgI etc); Instruments for environmental monitoring; food control and medical use;
D O I
10.1088/1748-0221/17/10/P10012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In our previous work, a cost-effective Compton camera (CC) using Ce doped Gd-3(Al,Ga)(5)O-12(Ce:GAGG) scintillator consisting of two detectors, scatterer (20.8 x 20.8 x 5mm(3)) and absorber (41.7 x 41.7 x 10 mm(3)), was developed to image gamma rays having energy more than 511 keV. This study fabricated a newly developed CC with a larger scatterer and thinner absorber. The system consists of two detectors: a scatterer and an absorber of Ce:GAGG scintillator. The size of the scatterer and absorber is the same; a 40 - mm x 40 - mm x 5-mm array block consists of 40 x 40 pixels. The size of each scintillator pixel is 0.85mm x 0.85mm for both systems. Imaging experiments of Na-22 and Cs-137 point sources were performed to investigate the imaging capability of the new camera, and then the obtained data were compared to the previous CC. The current CC's absolute detection efficiency (DEa) and photopeak detection efficiency (DEp) are improved by 1.6 and 2 times greater than the previous one. At the same time, both systems' spatial and angular resolutions are almost the same value at 511 keV. The Compton camera module (CCMod) in GATE v9.0 was employed for Monte Carlo simulations to reproduce the experimental data showing a good agreement.
引用
收藏
页数:18
相关论文
共 21 条
[1]   Performance evaluation of MACACO II Compton camera [J].
Barrientos, L. ;
Borja-Lloret, M. ;
Etxebeste, A. ;
Munoz, E. ;
Oliver, J. F. ;
Ros, A. ;
Roser, J. ;
Senra, C. ;
Viegas, R. ;
Llosa, G. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1014
[2]   ROOT - An object oriented data analysis framework [J].
Brun, R ;
Rademakers, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 389 (1-2) :81-86
[3]   CCMod: a GATE module for Compton camera imaging simulation [J].
Etxebeste, A. ;
Dauvergne, D. ;
Fontana, M. ;
Letang, J. M. ;
Llosa, G. ;
Munoz, E. ;
Oliver, J. F. ;
Testa, E. ;
Sarrut, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05)
[4]  
GEANT collaboration, 2020, GUID PHYS LISTS
[5]   Nuclear medical imaging using β+ γ coincidences from 44Sc radio-nuclide with liquid xenon as detection medium [J].
Grignon, C. ;
Barbet, J. ;
Bardies, M. ;
Carlier, T. ;
Chatal, J. F. ;
Couturier, O. ;
Cussonneau, J. P. ;
Faivre, A. ;
Ferrer, L. ;
Girault, S. ;
Haruyama, T. ;
Le Ray, P. ;
Luquin, L. ;
Lupone, S. ;
Metivier, V. ;
Morteau, E. ;
Servagent, N. ;
Thers, D. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :142-145
[6]   Electron-tracking Compton gamma-ray camera for small animal and phantom imaging [J].
Kabuki, Shigeto ;
Kimura, Hiroyuki ;
Amano, Hiroo ;
Nakamoto, Yuji ;
Kubo, Hidetoshi ;
Miuchi, Kentaro ;
Kurosawa, Shunsuke ;
Takahashi, Michiaki ;
Kawashima, Hidekazu ;
Ueda, Masashi ;
Okada, Tomohisa ;
Kubo, Atsushi ;
Kunieda, Etuso ;
Nakahara, Tadaki ;
Kohara, Ryota ;
Miyazaki, Osamu ;
Nakazawa, Tetsuo ;
Shirahata, Takashi ;
Yamamoto, Etsuji ;
Ogawa, Koichi ;
Togashi, Kaori ;
Saji, Hideo ;
Tanimori, Toru .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01) :606-607
[7]   Handy Compton camera using 3D position-sensitive scintillators coupled with large-area monolithic MPPC arrays [J].
Kataoka, J. ;
Kishimoto, A. ;
Nishiyama, T. ;
Fujita, T. ;
Takeuchi, K. ;
Kato, T. ;
Nakamori, T. ;
Ohsuka, S. ;
Nakamura, S. ;
Hirayanagi, M. ;
Adachi, S. ;
Uchiyama, T. ;
Yamamoto, K. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 :403-407
[8]   Development of a compact scintillator-based high-resolution Compton camera for molecular imaging [J].
Kishimoto, A. ;
Kataoka, J. ;
Koide, A. ;
Sueoka, K. ;
Iwamoto, Y. ;
Taya, T. ;
Ohsuka, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 :656-659
[9]   A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation [J].
Mizumoto, T. ;
Tomono, D. ;
Takada, A. ;
Tanimori, T. ;
Komura, S. ;
Kubo, H. ;
Matsuoka, Y. ;
Mizumura, Y. ;
Nakamura, K. ;
Nakamura, S. ;
Oda, M. ;
Parker, J. D. ;
Sawano, T. ;
Bando, N. ;
Nabetani, A. .
JOURNAL OF INSTRUMENTATION, 2015, 10
[10]   Development of a cost-effective Compton camera using a positron emission tomography data acquisition system [J].
Nagao, Yuto ;
Yamaguchi, Mitsutaka ;
Kawachi, Naoki ;
Watabe, Hiroshi .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 :20-23