Technical challenges and future directions in lead reconstruction for reduced-lead systems

被引:17
作者
Feild, Dirk Q. [1 ]
Zhou, Sophia H. [1 ]
Helfenbein, Eric D. [1 ]
Gregg, Richard E. [1 ]
Lindauer, James M. [1 ]
机构
[1] Philips Healthcare, Adv Algorithm Res Ctr, Thousand Oaks, CA 91320 USA
关键词
Electrocardiography; Reduced-lead systems; Lead reconstruction; Lead derivation;
D O I
10.1016/j.jelectrocard.2008.07.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reduced-lead electrocardiographic systems are currently a widely accepted medical technology used in a number of applications. They provide increased patient comfort and superior performance in arrhythmia and ST monitoring. These systems have unique and compelling advantages over the traditional multichannel monitoring lead systems. However, the design and development of reduced-lead systems create numerous technical challenges. This article summarizes the major technical challenges commonly encountered in lead reconstruction for reduced-lead systems. We discuss the effects of basis lead and target lead selections, the differences between interpolated vs extrapolated leads, the database dependency of the coefficients, and the approaches in quantitative performance evaluation, and provide a comparison of different lead systems. In conclusion, existing reduced-lead systems differ significantly in regard to trade-offs from the technical, practical, and clinical points of view. Understanding the technical limitations, the strengths, and the trade-offs of these reduced-lead systems will hopefully guide future research. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:466 / 473
页数:8
相关论文
共 25 条
  • [1] THE IMPORTANCE OF DERIVED 12-LEAD ELECTROCARDIOGRAPHY IN THE INTERPRETATION OF ARRHYTHMIAS DETECTED BY HOLTER RECORDING
    DENES, P
    [J]. AMERICAN HEART JOURNAL, 1992, 124 (04) : 905 - 911
  • [2] DOWER G E, 1980, Clinical Cardiology, V3, P87
  • [3] DERIVING THE 12-LEAD ELECTROCARDIOGRAM FROM 4 (EASI) ELECTRODES
    DOWER, GE
    YAKUSH, A
    NAZZAL, SB
    JUTZY, RV
    RUIZ, CE
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 : S182 - S187
  • [4] Drew B J, 1996, Am J Crit Care, V5, P198
  • [5] Comparison of a new reduced lead set ECG with the standard ECG for diagnosing cardiac arrhythmias and myocardial ischemia
    Drew, BJ
    Pelter, MM
    Brodnick, DE
    Yadav, AV
    Dempel, D
    Adams, MG
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2002, 35 : 13 - 21
  • [6] COMPARISON OF A VECTORCARDIOGRAPHICALLY DERIVED 12-LEAD ELECTROCARDIOGRAM WITH THE CONVENTIONAL ELECTROCARDIOGRAM DURING WIDE QRS COMPLEX TACHYCARDIA, AND ITS POTENTIAL APPLICATION FOR CONTINUOUS BEDSIDE MONITORING
    DREW, BJ
    SCHEINMAN, MM
    EVANS, GT
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06) : 612 - 618
  • [7] Improved EASI coefficients:: Their derivation, values, and performance
    Feild, DQ
    Feldman, CL
    Horácek, BM
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2002, 35 : 23 - 33
  • [8] Comparison of the five-electrode-derived EASI electrocardiogram to the mason likar electrocardiogram in the prehospital setting
    Feldman, CL
    Milstein, SZ
    Neubecker, D
    Underhill, BK
    Moyer, E
    Glumm, S
    Womble, M
    Auer, J
    Maynard, C
    Serra, RK
    Wagner, GS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (03) : 453 - 456
  • [9] Where do derived precordial leads fail?
    Gregg, Richard E.
    Zhou, Sophia H.
    Lindauer, James M.
    Feild, Dirk Q.
    Helfenbein, Eric D.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2008, 41 (06) : 546 - 552
  • [10] On designing and testing transformations for derivation of standard 12-lead/18-lead electrocardiograms and vectorcardiograms from reduced sets of predictor leads
    Horacek, B. Milan
    Warren, James W.
    Wang, John J.
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2008, 41 (03) : 220 - 229