On the Optimal Design of Cable Driven Parallel Robot with a Prescribed Workspace for Upper Limb Rehabilitation Tasks

被引:37
作者
Amine, Laribi Med [1 ]
Giuseppe, Carbone [2 ,3 ]
Said, Zeghloul [1 ]
机构
[1] Univ Poitiers, Dept GMSC, Pprime Inst, CNRS,ENSMA,UPR 3346, Poitiers, France
[2] Univ Calabria, Dept Mech Energy & Management Engn, I-87036 Arcavacata Di Rende, Italy
[3] Tech Univ Cluj Napoca, CESTER, Muncii Ave 103-105, Cluj Napoca 400641, Romania
关键词
LAWEX robot design; bionic robot; cable-driven robots; optimization; power of the point; rehabilitation tasks;
D O I
10.1007/s42235-019-0041-4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper deals with an optimization approach to design a cable driven parallel robot intended for upper limb rehabilitation tasks. The cable driven parallel robots have characteristics that make them best candidate for rehabilitation exercise purposes such as large workspace, re-configurable architecture, portability and cost effectiveness. Here, both the cable tensions that are needed to move a wristband as well as the workspace need to be carefully optimized for fulfilling the prescribed operation tasks. A specific case of study is addressed in this work by referring to LARM wire driven exercising device (LAWEX), which is applied to upper limbs exercises. To that end, a motion capture system is used to collect quantitative data on the prescribed workspace of a human upper limb. A specific optimization problem is settled up for considering combining two optimization goals, namely, the smallest robot size reaching a prescribed workspace and the minimum cable tension distributions. A sequence of optimization steps is defined using Genetic Algorithms (GAs) applied to LAWEX robot. The proposed objective function is based on a mathematical formulation of the power of a point with respect to bounding surfaces in combination with a performance index to show the distributions of the minimum cable tensions.
引用
收藏
页码:503 / 513
页数:11
相关论文
共 31 条
[1]  
Agrawal S, 2015, US Patent US, Patent No. [9144528 B2, 9144528]
[2]  
Ben Hamida I, 2019, ROMANSY 22 ROBOT DES, V584, P180, DOI [10.1007/978-3-319-78963-7_24, DOI 10.1007/978-3-319-78963-7_24]
[3]   ON THE OPTIMUM DESIGN OF STEWART PLATFORM TYPE PARALLEL MANIPULATORS [J].
BHATTACHARYA, S ;
HATWAL, H ;
GHOSH, A .
ROBOTICA, 1995, 13 :133-140
[4]   A Study of Feasibility for a Limb Exercising Device [J].
Carbone, G. ;
Arostegui Cavero, C. ;
Ceccarelli, M. ;
Altuzarra, O. .
ADVANCES IN ITALIAN MECHANISM SCIENCE, 2017, 47 :11-21
[5]   Design Issues for an Inherently Safe Robotic Rehabilitation Device [J].
Carbone, Giuseppe ;
Gherman, Bogdan ;
Ulinici, Ionut ;
Vaida, Calin ;
Pisla, Doina .
ADVANCES IN SERVICE AND INDUSTRIAL ROBOTICS, 2018, 49 :1025-1032
[6]  
Ceccarelli M., 2004, FUNDAMENTALS MECH RO, V1st
[7]  
Ceccarelli M, 2014, MECH MACH SCI, V16, P27, DOI 10.1007/978-3-319-01592-7_3
[8]   Optimal synthesis of a spherical parallel mechanism for medical application [J].
Essomba, T. ;
Laribi, M. A. ;
Zeghloul, S. ;
Poisson, G. .
ROBOTICA, 2016, 34 (03) :671-686
[9]   On the design of cable-suspended planar parallel robots [J].
Fattah, A ;
Agrawal, SK .
JOURNAL OF MECHANICAL DESIGN, 2005, 127 (05) :1021-1028
[10]   Cable-driven parallel mechanisms: state of the art and perspectives [J].
Gosselin, Clement .
MECHANICAL ENGINEERING REVIEWS, 2014, 1 (01)