Benefits of Point-Spread Function and Time of Flight for PET/CT Image Quality in Relation to the Body Mass Index and Injected Dose

被引:19
|
作者
Akamatsu, Go [1 ]
Mitsumoto, Katsuhiko [1 ]
Ishikawa, Kaori [1 ]
Taniguchi, Takafumi [1 ]
Ohya, Nobuyoshi [2 ]
Baba, Shingo [3 ]
Abe, Koichiro [3 ]
Sasaki, Masayuki [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Fukuoka 8128582, Japan
[2] Kyushu Univ Hosp, Dept Med Technol, Fukuoka, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka 8128582, Japan
基金
日本学术振兴会;
关键词
point-spread function; time-of-flight; image quality; BMI; injected dose; POSITRON-EMISSION-TOMOGRAPHY; LESION DETECTION; F-18-FDG PET/CT; PATIENT WEIGHT; SCAN DURATION; LUNG-CANCER; IMPACT; RECONSTRUCTION; PROTOCOLS; PERFORMANCE;
D O I
10.1097/RLU.0b013e31828da3bd
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The PET image quality of overweight patients and patients who receive low injected doses deteriorates because of increases in statistical noise. The purpose of this study was to investigate the benefits of the point-spread function (PSF) and time-of-flight (TOF) for PET/CT image quality in such patients. Methods: The PET images were reconstructed using the baseline ordered-subsets expectation-maximization algorithm (OSEM), OSEM + PSF, OSEM + TOF, and OSEM + PSF + TOF. In the phantom study, we used a National Electrical Manufacturers Association body phantom with different radioactivity concentrations and analyzed image quality using the coefficient of variance in the background (CVphantom). In the clinical study, we retrospectively studied 39 patients who underwent clinical F-18-FDG PET/CT. The patients were classified into groups based on body mass index and injected dose. Image quality was evaluated using the CV in the liver (CVliver). Results: In the phantom study, PSF and TOF improved the CVphantom, especially in low-activity models. Among all of the reconstructions, the best CVphantom was obtained with OSEM + PSF + TOF. In the clinical study, the CVliver of the low-dose group with OSEM + PSF + TOF was comparable to that of the high-dose group with conventional OSEM. Conclusions: Point-spread function and TOF improved PET/CT image quality for overweight patients who received a lower injected dose. Therefore, the use of PSF and TOF is suggested to maintain the image quality of such patients without extending scanning times. It is greatly beneficial to obtain sufficient image quality for larger patients, especially in delivery institutions where the injection dose cannot be easily increased.
引用
收藏
页码:407 / 412
页数:6
相关论文
共 50 条
  • [31] Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study
    Yang, Ching-Ching
    Liu, Shu-Hsin
    Mok, Greta S. P.
    Wu, Tung-Hsin
    MEDICAL PHYSICS, 2014, 41 (09)
  • [32] Achieving consistent image quality and overall radiation dose reduction for coronary CT angiography with body mass index-dependent tube voltage and tube current selection
    Wang, G.
    Gao, J.
    Zhao, S.
    Sun, X.
    Chen, X.
    Cui, X.
    CLINICAL RADIOLOGY, 2014, 69 (09) : 945 - 951
  • [33] The association of tumor-to-background ratios and SUVmax deviations related to point spread function and time-of-flight F18-FDG-PET/CT reconstruction in colorectal liver metastases
    Rogasch, Julian M. M.
    Steffen, Ingo G.
    Hofheinz, Frank
    Grosser, Oliver S.
    Furth, Christian
    Mohnike, Konrad
    Hass, Peter
    Walke, Mathias
    Apostolova, Ivayla
    Amthauer, Holger
    EJNMMI RESEARCH, 2015, 5 : 1 - 9
  • [34] CT pulmonary angiography using different noise index values with an iterative reconstruction algorithm and dual energy CT imaging using different body mass indices: Image quality and radiation dose
    Zhao, Yongxia
    Wu, Yanmin
    Zuo, Ziwei
    Suo, Hongna
    Zhao, Sisi
    Zhang, Haisong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (01) : 79 - 91
  • [35] Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT—Initial Results
    Konstantinos G. Zeimpekis
    Felipe Barbosa
    Martin Hüllner
    Edwin ter Voert
    Helen Davison
    Patrick Veit-Haibach
    Gaspar Delso
    Molecular Imaging and Biology, 2015, 17 : 735 - 744
  • [36] Image quality and quantification accuracy dependence on patient body mass in 89Zr PET/CT imaging
    Tateishi, Ukihide
    Daisaki, Hiromitsu
    Tsuchiya, Junichi
    Kojima, Yuji
    Takino, Keisuke
    Shimada, Naoki
    Yokoyama, Kota
    EJNMMI PHYSICS, 2021, 8 (01)
  • [37] Image quality and quantification accuracy dependence on patient body mass in 89Zr PET/CT imaging
    Ukihide Tateishi
    Hiromitsu Daisaki
    Junichi Tsuchiya
    Yuji Kojima
    Keisuke Takino
    Naoki Shimada
    Kota Yokoyama
    EJNMMI Physics, 8
  • [38] Whole-Body PET/CT Studies with Lowered F-18-FDG Doses: The Influence of Body Mass Index in Dose Reduction
    Sanchez-Jurado, Raul
    Devis, Manuel
    Sanz, Rut
    Enrique Aguilar, Jose
    del Puig Cozar, Maria
    Ferrer-Rebolleda, Jose
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2014, 42 (01) : 62 - 67
  • [39] Added Value of Digital over Analog PET/CT: More Significant as Image Field of View and Body Mass Index Increase
    Hatami, Shirin
    Frye, Sarah
    McMunn, Anna
    Botkin, Crystal
    Muzaffar, Razi
    Christopher, Kara
    Osman, Medhat
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2020, 48 (04) : 354 - 360
  • [40] CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose
    Zhao, Yong-Xia
    Zuo, Zi-Wei
    Suo, Hong-Na
    Wang, Jia-ning
    Chang, Jin
    ACADEMIC RADIOLOGY, 2016, 23 (12) : 1513 - 1520