Benefits of Point-Spread Function and Time of Flight for PET/CT Image Quality in Relation to the Body Mass Index and Injected Dose

被引:19
|
作者
Akamatsu, Go [1 ]
Mitsumoto, Katsuhiko [1 ]
Ishikawa, Kaori [1 ]
Taniguchi, Takafumi [1 ]
Ohya, Nobuyoshi [2 ]
Baba, Shingo [3 ]
Abe, Koichiro [3 ]
Sasaki, Masayuki [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Hlth Sci, Fukuoka 8128582, Japan
[2] Kyushu Univ Hosp, Dept Med Technol, Fukuoka, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka 8128582, Japan
基金
日本学术振兴会;
关键词
point-spread function; time-of-flight; image quality; BMI; injected dose; POSITRON-EMISSION-TOMOGRAPHY; LESION DETECTION; F-18-FDG PET/CT; PATIENT WEIGHT; SCAN DURATION; LUNG-CANCER; IMPACT; RECONSTRUCTION; PROTOCOLS; PERFORMANCE;
D O I
10.1097/RLU.0b013e31828da3bd
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The PET image quality of overweight patients and patients who receive low injected doses deteriorates because of increases in statistical noise. The purpose of this study was to investigate the benefits of the point-spread function (PSF) and time-of-flight (TOF) for PET/CT image quality in such patients. Methods: The PET images were reconstructed using the baseline ordered-subsets expectation-maximization algorithm (OSEM), OSEM + PSF, OSEM + TOF, and OSEM + PSF + TOF. In the phantom study, we used a National Electrical Manufacturers Association body phantom with different radioactivity concentrations and analyzed image quality using the coefficient of variance in the background (CVphantom). In the clinical study, we retrospectively studied 39 patients who underwent clinical F-18-FDG PET/CT. The patients were classified into groups based on body mass index and injected dose. Image quality was evaluated using the CV in the liver (CVliver). Results: In the phantom study, PSF and TOF improved the CVphantom, especially in low-activity models. Among all of the reconstructions, the best CVphantom was obtained with OSEM + PSF + TOF. In the clinical study, the CVliver of the low-dose group with OSEM + PSF + TOF was comparable to that of the high-dose group with conventional OSEM. Conclusions: Point-spread function and TOF improved PET/CT image quality for overweight patients who received a lower injected dose. Therefore, the use of PSF and TOF is suggested to maintain the image quality of such patients without extending scanning times. It is greatly beneficial to obtain sufficient image quality for larger patients, especially in delivery institutions where the injection dose cannot be easily increased.
引用
收藏
页码:407 / 412
页数:6
相关论文
共 50 条
  • [1] Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters
    Akamatsu, Go
    Ishikawa, Kaori
    Mitsumoto, Katsuhiko
    Taniguchi, Takafumi
    Ohya, Nobuyoshi
    Baba, Shingo
    Abe, Koichiro
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) : 1716 - 1722
  • [2] Clinical evaluation of whole-body oncologic PET with time-of-flight and point-spread function for the hybrid PET/MR system
    Shang, Kun
    Cui, Bixiao
    Ma, Jie
    Shuai, Dongmei
    Liang, Zhigang
    Jansen, Floris
    Zhou, Yun
    Lu, Jie
    Zhao, Guoguang
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 70 - 75
  • [3] Optimization of PET/CT image quality using the GE "Sharp IR' point-spread function reconstruction algorithm
    Vennart, Nicholas J.
    Bird, Nicholas
    Buscombe, John
    Cheow, Heok K.
    Nowosinska, Ewa
    Heard, Sarah
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (06) : 471 - 479
  • [4] Impact of Point-Spread Function Modeling on PET Image Quality in Integrated PET/MR Hybrid Imaging
    Aklan, Bassim
    Oehmigen, Mark
    Beiderwellen, Karsten
    Ruhlmann, Marcus
    Paulus, Daniel H.
    Jakoby, Bjoern W.
    Ritt, Philipp
    Quick, Harald H.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (01) : 78 - 84
  • [5] Contribution of time of flight and point spread function modeling to the performance characteristics of the PET/CT Biograph mCT scanner
    Marti-Climent, J. M.
    Prieto, E.
    Dominguez-Prado, I.
    Garcia-Velloso, M. J.
    Rodriguez-Fraile, M.
    Arbizu, J.
    Vigil, C.
    Caicedo, C.
    Penuelas, I.
    Richter, J. A.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2013, 32 (01): : 13 - 21
  • [6] Effect of time-of-flight and point spread function modeling on detectability of myocardial defects in PET
    Schaefferkoetter, Joshua
    Ouyang, Jinsong
    Rakvongthai, Yothin
    Nappi, Carmela
    El Fakhri, Georges
    MEDICAL PHYSICS, 2014, 41 (06)
  • [7] Influences of point-spread function and time-of-flight reconstructions on standardized uptake value of lymph node metastases in FDG-PET
    Akamatsu, Go
    Mitsumoto, Katsuhiko
    Taniguchi, Takafumi
    Tsutsui, Yuji
    Baba, Shingo
    Sasaki, Masayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (01) : 226 - 230
  • [8] Optimal reconstruction matrix and PET image filtration for point-spread function and time-of-flight reconstruction - A phantom study
    Ptacek, Jaroslav
    Karhan, Pavel
    Fiala, Petr
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 39 : 95 - 99
  • [9] Applications of both time of flight and point spread function in brain PET image reconstruction
    Shao, Xiaonan
    Shao, Xiaoliang
    Wang, Xiaosong
    Wang, Yuetao
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (04) : 422 - 427
  • [10] The impact of reconstruction algorithms and time of flight information on PET/CT image quality
    Suljic, Alen
    Tomse, Petra
    Jensterle, Luka
    Skrk, Damijan
    RADIOLOGY AND ONCOLOGY, 2015, 49 (03) : 227 - 233