Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams

被引:133
|
作者
Hosseinpour, Emad [1 ]
Baharom, Shahrizan [1 ]
Badaruzzaman, Wan Hamidon W. [1 ]
Shariati, Mahdi [2 ]
Jalali, Abdolrahim [2 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Civil & Struct Engn, Bangi 43600, Selangor, Malaysia
[2] Univ Tabriz, Fac Civil Engn, Bahman Blvd, Tabriz 5166616471, Iran
来源
STEEL AND COMPOSITE STRUCTURES | 2018年 / 26卷 / 04期
关键词
slim-floor; hollow steel tube; shear connector; push-out test; energy absorption capacity; COMPOSITE BEAMS; DESIGN;
D O I
10.12989/scs.2018.26.4.485
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a hollow steel tube (HST) shear connector is proposed for use in a slim-floor system. The HST welded to a perforated steel beam web and embedded in concrete slab. A total of 10 push-out tests were conducted under static loading to investigate the mechanical behavior of the proposed HST connector. The variables were the shapes (circular, square and rectangular) and sizes of hollow steel tubes, and the compressive strength of the concrete. The failure mode was recorded as: concrete slab compressive failure under the steel tube and concrete tensile splitting failure, where no failure occurred in the HST. Test results show that the square shape HST in filled via concrete strength 40 MPa carried the highest shear load value, showing three times more than the reference specimens. It also recorded less slip behavior, and less compressive failure mode in concrete underneath the square hollow connector in comparison with the circular and rectangular HST connectors in both concrete strengths. The rectangular HST shows a 20% higher shear resistance with a longer width in the load direction in comparison with that in the smaller dimension. The energy absorption capacity values showed 23% and 18% improvements with the square HST rather than a headed shear stud when embedded in concrete strengths of 25 MPa and 40 MPa, respectively. Moreover, an analytical method was proposed and predicts the shear resistance of the HST shear connectors with a standard deviation of 0.14 considering the shape and size of the connectors.
引用
收藏
页码:485 / 499
页数:15
相关论文
共 50 条
  • [21] Truss-type shear connector for composite steel-concrete beams
    Bezerra, Luciano M.
    Barbosa, Wallison C. S.
    Bonilla, Jorge
    Cavalcante, Otavio R. O.
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 167 : 757 - 767
  • [22] The Seismic Behavior of The Materials Used in the Steel-Plate Shear Walls with Concrete Filled Steel Tube Columns
    Wang, Yaohong
    Cao, Wanlin
    Li, Gang
    ADVANCED ENGINEERING MATERIALS, PTS 1-3, 2011, 194-196 : 2014 - 2017
  • [23] Shear strength of connections between concrete filled steel tubes and beams
    Jian, Li
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 75 - 79
  • [24] Behavior of a New Type of Shear Connector for U-Shaped Steel-Concrete Hybrid Beams
    Keo, Pisey
    Lepourry, Clemence
    Somja, Hugues
    Palas, Frank
    HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 1344 - 1352
  • [25] Study of the behavior and resistance of right-angle truss shear connector for composite steel concrete beams
    Lima, Jerfson M.
    Bezerra, Luciano M.
    Bonilla, Jorge
    Barbosa, Wallison C. S.
    ENGINEERING STRUCTURES, 2022, 253
  • [26] Seismic behavior and shear capacity prediction of coupled concrete-filled multicellular steel tube composite shear walls
    Zheng, Hong
    Mi, Yuxi
    Cai, Lele
    Wang, Guang
    Jiang, Liqiang
    Ma, Xiaoming
    Lu, Guiqiang
    Chen, Yuanjun
    STRUCTURAL CONCRETE, 2024, 25 (03) : 1999 - 2019
  • [27] The Effect of Steel Strength on the Behavior of a K-Joint in a Slim-floor Truss
    Saremi, Pooya
    Lu, Wei
    Puttonen, Jari
    Pada, Dan
    Kesti, Jyrki
    Puttonen, Jari (jari.puttonen@aalto.fi), 1600, John Wiley and Sons Inc (04): : 2 - 4
  • [28] SHEAR BEHAVIOR OF STEEL FIBER REINFORCED-CONCRETE BEAMS
    TAN, KH
    MURUGAPPAN, K
    PARAMASIVAM, P
    ACI STRUCTURAL JOURNAL, 1993, 90 (01) : 3 - 11
  • [29] Experimental study on ultimate strength of concrete filled double tubular steel with shear connector
    Masaru Shimizu
    Fumihito Tatsumi
    Toshiyuki Ishikawa
    Atsushi Hattori
    Hirotaka Kawano
    International Journal of Steel Structures, 2013, 13 : 49 - 54
  • [30] Experimental study on ultimate strength of concrete filled double tubular steel with shear connector
    Shimizu, Masaru
    Tatsumi, Fumihito
    Ishikawa, Toshiyuki
    Hattori, Atsushi
    Kawano, Hirotaka
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2013, 13 (01) : 49 - 54