Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams

被引:133
|
作者
Hosseinpour, Emad [1 ]
Baharom, Shahrizan [1 ]
Badaruzzaman, Wan Hamidon W. [1 ]
Shariati, Mahdi [2 ]
Jalali, Abdolrahim [2 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Civil & Struct Engn, Bangi 43600, Selangor, Malaysia
[2] Univ Tabriz, Fac Civil Engn, Bahman Blvd, Tabriz 5166616471, Iran
来源
STEEL AND COMPOSITE STRUCTURES | 2018年 / 26卷 / 04期
关键词
slim-floor; hollow steel tube; shear connector; push-out test; energy absorption capacity; COMPOSITE BEAMS; DESIGN;
D O I
10.12989/scs.2018.26.4.485
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a hollow steel tube (HST) shear connector is proposed for use in a slim-floor system. The HST welded to a perforated steel beam web and embedded in concrete slab. A total of 10 push-out tests were conducted under static loading to investigate the mechanical behavior of the proposed HST connector. The variables were the shapes (circular, square and rectangular) and sizes of hollow steel tubes, and the compressive strength of the concrete. The failure mode was recorded as: concrete slab compressive failure under the steel tube and concrete tensile splitting failure, where no failure occurred in the HST. Test results show that the square shape HST in filled via concrete strength 40 MPa carried the highest shear load value, showing three times more than the reference specimens. It also recorded less slip behavior, and less compressive failure mode in concrete underneath the square hollow connector in comparison with the circular and rectangular HST connectors in both concrete strengths. The rectangular HST shows a 20% higher shear resistance with a longer width in the load direction in comparison with that in the smaller dimension. The energy absorption capacity values showed 23% and 18% improvements with the square HST rather than a headed shear stud when embedded in concrete strengths of 25 MPa and 40 MPa, respectively. Moreover, an analytical method was proposed and predicts the shear resistance of the HST shear connectors with a standard deviation of 0.14 considering the shape and size of the connectors.
引用
收藏
页码:485 / 499
页数:15
相关论文
共 50 条
  • [11] NUMERICAL MODELLING AND PARAMETRIC STUDY OF SLIM-FLOOR COMPOSITE SHEAR BEAMS
    Dai, Xianghe
    Lam, Dennis
    Sheehan, Therese
    Yang, Jie
    Zhou, Kan
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 836 - 847
  • [12] Behavior of an Advanced Bolted Shear Connector in Prefabricated Steel-Concrete Composite Beams
    Chen, Jun
    Wang, Wei
    Ding, Fa-Xing
    Xiang, Ping
    Yu, Yu-Jie
    Liu, Xue-Mei
    Xu, Fu
    Yang, Cai-Qian
    Long, Shi-Guo
    MATERIALS, 2019, 12 (18)
  • [13] Shear strength tests of concrete filled steel tube columns
    Qian, Jiaru
    Cui, Yao
    Fang, Xiaodan
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2007, 40 (05): : 1 - 9
  • [14] Behavior of a new shear connector for U-shaped steel-concrete hybrid beams
    Keo, Pisey
    Lepourry, Clemence
    Somja, Hugues
    Palas, Frank
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 145 : 153 - 166
  • [15] Shear performance of lightweight concrete filled hollow flange cold-formed steel beams
    Sifan, Mohamed
    Gatheeshgar, Perampalam
    Nagaratnam, Brabha
    Poologanathan, Keerthan
    Navaratnam, Satheeskumar
    Thamboo, Julian
    Corradi, Marco
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [16] Effect of Shear Connector Layout on the Behavior of Steel-Concrete Composite Beams with Interface Slip
    Zeng, Xinggui
    Jiang, Shao-Fei
    Zhou, Donghua
    APPLIED SCIENCES-BASEL, 2019, 9 (01):
  • [17] Behavior and resistance of truss-type shear connector for composite steel- concrete beams
    Lima, Jerfson M.
    Bezerra, Luciano M.
    Bonilla, Jorge
    Silva, Ramon S. Y. R. C.
    Barbosa, Wallison C. S.
    STEEL AND COMPOSITE STRUCTURES, 2020, 36 (05): : 569 - 586
  • [18] Shear behavior of high-strength square concrete filled steel tube members
    Lai, Zhichao
    Han, Wenbing
    Wang, Ying
    Yang, Xiaoqiang
    Huang, Wenjin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [19] Experimental Study on Mechanical Behavior of Shear Connectors of Square Concrete Filled Steel Tube
    Qiao, Qiyun
    Zhang, Wenwen
    Qian, Zhiwei
    Cao, Wanlin
    Liu, Wenchao
    APPLIED SCIENCES-BASEL, 2017, 7 (08):
  • [20] Internally fire protected composite steel-concrete slim-floor beam
    Albero, V.
    Serra, E.
    Espinos, A.
    Romero, M. L.
    Hospitaler, A.
    ENGINEERING STRUCTURES, 2021, 227