Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams

被引:133
|
作者
Hosseinpour, Emad [1 ]
Baharom, Shahrizan [1 ]
Badaruzzaman, Wan Hamidon W. [1 ]
Shariati, Mahdi [2 ]
Jalali, Abdolrahim [2 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Civil & Struct Engn, Bangi 43600, Selangor, Malaysia
[2] Univ Tabriz, Fac Civil Engn, Bahman Blvd, Tabriz 5166616471, Iran
来源
STEEL AND COMPOSITE STRUCTURES | 2018年 / 26卷 / 04期
关键词
slim-floor; hollow steel tube; shear connector; push-out test; energy absorption capacity; COMPOSITE BEAMS; DESIGN;
D O I
10.12989/scs.2018.26.4.485
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a hollow steel tube (HST) shear connector is proposed for use in a slim-floor system. The HST welded to a perforated steel beam web and embedded in concrete slab. A total of 10 push-out tests were conducted under static loading to investigate the mechanical behavior of the proposed HST connector. The variables were the shapes (circular, square and rectangular) and sizes of hollow steel tubes, and the compressive strength of the concrete. The failure mode was recorded as: concrete slab compressive failure under the steel tube and concrete tensile splitting failure, where no failure occurred in the HST. Test results show that the square shape HST in filled via concrete strength 40 MPa carried the highest shear load value, showing three times more than the reference specimens. It also recorded less slip behavior, and less compressive failure mode in concrete underneath the square hollow connector in comparison with the circular and rectangular HST connectors in both concrete strengths. The rectangular HST shows a 20% higher shear resistance with a longer width in the load direction in comparison with that in the smaller dimension. The energy absorption capacity values showed 23% and 18% improvements with the square HST rather than a headed shear stud when embedded in concrete strengths of 25 MPa and 40 MPa, respectively. Moreover, an analytical method was proposed and predicts the shear resistance of the HST shear connectors with a standard deviation of 0.14 considering the shape and size of the connectors.
引用
收藏
页码:485 / 499
页数:15
相关论文
共 50 条
  • [1] Structural capacity of a composite slim-floor beam with hollow steel tube shear connectors
    Majdub, Mohamed S.
    Baharom, Shahrizan
    Al Zand, Ahmed W.
    Mutalib, Azrul A.
    MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2024, 52 (10) : 7637 - 7669
  • [2] Effect of dowel shear connector on performance of slim-floor composite shear beams
    Dai, Xianghe
    Lam, Dennis
    Sheehan, Therese
    Yang, Jie
    Zhou, Kan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 173
  • [3] Effect of dowel shear connector on performance of slim-floor composite shear beams
    Dai, Xianghe
    Lam, Dennis
    Sheehan, Therese
    Yang, Jie
    Zhou, Kan
    Dai, Xianghe (x.dai@bradford.ac.uk), 1600, Elsevier Ltd (173):
  • [4] Shear resistance of concrete dowels in composite slim-floor beams
    Aggelopoulos, Eleftherios
    Schorr, Johannes
    Kuhlmann, Ulrike
    ce/papers, 2021, 4 (2-4) : 772 - 780
  • [5] Numerical modelling and analysis of dowel shear connector for composite slim-floor beams
    Xu, Xinxin
    Dai, Xianghe
    Lam, Dennis
    ADVANCES IN STRUCTURAL ENGINEERING, 2025,
  • [6] Partial shear diagram of slim-floor beams
    Zhang, Qingjie
    Schäfer, Markus
    ce/papers, 2021, 4 (2-4) : 685 - 690
  • [7] Perforated shear connector for composite steel and concrete beams
    Machacek, J
    Studnicka, J
    Krpata, A
    Svitakova, M
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 297 - 304
  • [8] A review on fire resistance of steel-concrete composite slim-floor beams
    Memarzadeh, Armin
    Shahmansouri, Amir Ali
    Nematzadeh, Mahdi
    Gholampour, Aliakbar
    STEEL AND COMPOSITE STRUCTURES, 2021, 40 (01): : 13 - 32
  • [9] Push-out test on the web opening shear connector for a slim-floor steel beam: Experimental and analytical study
    Hosseinpour, Emad
    Baharom, Shahrizan
    Badaruzzaman, Wan Hamidon W.
    Al Zand, Ahmed W.
    ENGINEERING STRUCTURES, 2018, 163 : 137 - 152
  • [10] Impact the shear connector properties on the behavior of steel- concrete-steel sandwich beams
    Mhalhal, Jasim M.
    Alawsi, Manal A.
    Al-Gasham, Thaar S.
    Abid, Sallal R.
    MATERIALS TODAY-PROCEEDINGS, 2022, 56 : 2043 - 2047