Preparation and evaluation of high efficient rod-shape poly(methacrylic acid-styrene-divinylbenzene) high performance liquid chromatographic column

被引:0
作者
Wang, JF [1 ]
Meng, ZH [1 ]
Zhou, LM [1 ]
Wang, QH [1 ]
Zhu, DQ [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116012, Peoples R China
关键词
high performance liquid chromatography column; in situ polymerization; (methacrylic acid-styrene-divinylbenzene) copolymer; polycyclic aromatic hydrocarbons;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel high efficiency rod-shape poly(methacrylic acid-co-styrene-co-divinylbenzene) high performance liquid chromatographic column was prepared by a free-radical polymerization directly within the column. Scanning electron micrograph revealed the macropores of the copolymer column media. It had excellent permeability and the column pressure was only 2.5 MPa at a flow-rate of 2.0 mL/min with acetonitrile-water (90/10, V/V) as mobile phase. It also showed the rather high efficiency with the theoretical plates being 40,000 plates per meter. Aromatic acids and polycyclic aromatic hydrocarbons were separated within 4 and 10 minutes, respectively.
引用
收藏
页码:745 / 748
页数:4
相关论文
共 10 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (ADVANCES IN PACKING MATERIALS) [J].
ANDERSON, DJ .
ANALYTICAL CHEMISTRY, 1995, 67 (12) :R475-R486
[2]   CHROMATOGRAPHIC CHARACTERISTICS OF POLYMER-BASED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PACKINGS [J].
DAWKINS, JV ;
LLOYD, LL ;
WARNER, FP .
JOURNAL OF CHROMATOGRAPHY, 1986, 352 :157-167
[3]   CHROMATOGRAPHIC EVALUATION OF LARGE-PORE AND NON-POROUS POLYMERIC REVERSED PHASES [J].
LEE, DP .
JOURNAL OF CHROMATOGRAPHY, 1988, 443 :143-153
[4]   RIGID MACROPOROUS COPOLYMERS AS STATIONARY PHASES IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LLOYD, LL .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :201-217
[5]  
MAJORS RE, 1993, LC GC-MAG SEP SCI, V11, P778
[6]   Molded monolithic rod of macroporous poly(styrene-co-divinylbenzene) as a separation medium for HPLC of synthetic polymers: ''On-column'' precipitation-redissolution chromatography as an alternative to size exclusion chromatography of styrene oligomers and polymers [J].
Petro, M ;
Svec, F ;
Gitsov, I ;
Frechet, JMJ .
ANALYTICAL CHEMISTRY, 1996, 68 (02) :315-321
[7]   Molded continuous poly(styrene-co-divinylbenzene) rod as a separation medium for the very fast separation of polymers - Comparison of the chromatographic properties of the monolithic rod with columns packed with porous and non-porous beads in high-performance liquid chromatography of polystyrenes [J].
Petro, M ;
Svec, F ;
Frechet, JMJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 752 (1-2) :59-66
[8]  
SEVC F, 1992, ANAL CHEM, V54, P820
[9]   MACROPOROUS POLYMERIC STATIONARY-PHASE ROD AS CONTINUOUS SEPARATION MEDIUM FOR REVERSED-PHASE CHROMATOGRAPHY [J].
WANG, QC ;
SVEC, F ;
FRECHET, JMJ .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2243-2248
[10]   REVERSED-PHASE CHROMATOGRAPHY OF SMALL MOLECULES AND PEPTIDES ON A CONTINUOUS ROD OF MACROPOROUS POLY(STYRENE-CO-DIVINYLBENZENE) [J].
WANG, QC ;
SVEC, F ;
FRECHET, JMJ .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :230-235