patient registration; volumetric 3D ultrasound; 3DUS-MR registration; image-guided neurosurgery; diagnostic and operative techniques; IMAGE-GUIDED NEUROSURGERY; BRAIN SHIFT; MODEL; DEFORMATION; SURVIVAL; NEURONAVIGATION; ACCURATE; SURGERY; MR;
D O I
10.3171/2014.12.JNS141321
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECT Fiducial-based registration (FBR) is used widely for patient registration in image-guided neurosurgery. The authors of this study have developed an automatic fiducial-less registration (FLR) technique to find the patient-to-image transformation by directly registering 3D ultrasound (3DUS) with MR images without incorporating prior information. The purpose of the study was to evaluate the performance of the FLR technique when used prospectively in the operating room and to compare it with conventional FBR. METHODS In 32 surgical patients who underwent conventional FBR, preoperative T1-weighted MR images (pMR) with attached fiducial markers were acquired prior to surgery. After craniotomy but before dural opening, a set of 3DUS images of the brain volume was acquired. A 2-step registration process was executed immediately after image acquisition: 1) the cortical surfaces from pMR and 3DUS were segmented, and a multistart sum-of-squared-intensity-difference registration was executed to find an initial alignment between down-sampled binary pMR and 3DUS volumes; and 2) the alignment was further refined by a mutual information-based registration between full-resolution grayscale pMR and. 3DUS images, and a patient-to-image transformation was subsequently extracted. RESULTS To assess the accuracy of the FLR technique, the following were quantified: 1) the fiducial distance error (FDE); and 2) the target registration error (TRE) at anterior commissure and posterior commissure locations; these were compared with conventional FBR. The results showed that although the average FDE (6.42 +/- 2.05 mm) was higher than the fiducial registration error (FRE) from FBR (3.42 +/- 1.37 mm), the overall IRE of FLR (2.51 +/- 0.93 mm) was lower than that of FBR(5.48 +/- 1.81 mm). The results agreed with the intent of the 2 registration techniques: FBR is designed to minimize the FRE, whereas FLR is designed to optimize feature alignment and hence minimize TRE. The overall computational cost of FLR was approximately 4-5 minutes and minimal user interaction was required. CONCLUSIONS Because the FLR method directly registers 3DUS with MR by matching internal image features, it proved to be more accurate than FBR in terms of TRE in the 32 patients evaluated in this study. The overall efficiency of FLR in terms of the time and personnel involved is also improved relative to FBR in the operating room, and the method does not require additional image scans immediately prior to surgery. The performance of FLR and these results suggest potential for broad clinical application.
引用
收藏
页码:721 / 731
页数:11
相关论文
共 33 条
  • [1] Factors influencing survival in high-grade gliomas
    Buckner, JC
    [J]. SEMINARS IN ONCOLOGY, 2003, 30 (06) : 10 - 14
  • [2] Laser range scanning for image-guided neurosurgery: Investigation of image-to-physical space registrations
    Cao, Aize
    Thompson, R. C.
    Dumpuri, P.
    Dawant, B. M.
    Galloway, R. L.
    Ding, S.
    Miga, M. I.
    [J]. MEDICAL PHYSICS, 2008, 35 (04) : 1593 - 1605
  • [3] Application of soft tissue modelling to image-guided surgery
    Carter, TJ
    Sermesant, M
    Cash, DM
    Barratt, DC
    Tanner, C
    Hawkes, DJ
    [J]. MEDICAL ENGINEERING & PHYSICS, 2005, 27 (10) : 893 - 909
  • [4] Survival rates in patients with low-grade glioma after intraoperative magnetic resonance image guidance
    Claus, EB
    Horlacher, A
    Hsu, LG
    Schwartz, RB
    Dello-Iacono, D
    Talos, F
    Jolesz, FA
    Black, PM
    [J]. CANCER, 2005, 103 (06) : 1227 - 1233
  • [5] Stereovision to MR image registration for cortical surface displacement mapping to enhance image-guided neurosurgery
    Fan, Xiaoyao
    Ji, Songbai
    Hartov, Alex
    Roberts, David W.
    Paulsen, Keith D.
    [J]. MEDICAL PHYSICS, 2014, 41 (10)
  • [6] Simulation of Brain Tumor Resection in Image-guided Neurosurgery
    Fan, Xiaoyao
    Ji, Songbai
    Fontaine, Kathryn
    Hartov, Alex
    Roberts, David
    Paulsen, Keith
    [J]. MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [7] Serial registration of intraoperative MR images of the brain
    Ferrant, M
    Nabavi, A
    Macq, B
    Black, PM
    Jolesz, FA
    Kikinis, R
    Warfield, SK
    [J]. MEDICAL IMAGE ANALYSIS, 2002, 6 (04) : 337 - 359
  • [8] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [9] CURVATURE-BASED NONFIDUCIAL REGISTRATION FOR THE FRAMELESS STEREOTAXIC OPERATING MICROSCOPE
    FRIETS, EM
    STROHBEHN, JW
    ROBERTS, DW
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (09) : 867 - 878
  • [10] More accurate neuronavigation data provided by biomechanical modeling instead of rigid registration
    Garlapati, Revanth Reddy
    Roy, Aditi
    Joldes, Grand Roman
    Wittek, Adam
    Mostayed, Ahmed
    Doyle, Barry
    Warfield, Simon Keith
    Kikinis, Ron
    Knuckey, Neville
    Bunt, Stuart
    Miller, Karol
    [J]. JOURNAL OF NEUROSURGERY, 2014, 120 (06) : 1477 - 1483