Effect of mechanical load cycling on the marginal integrity of adhesive Class I resin composite restorations

被引:35
作者
Abdalla, AI
Davidson, CL
机构
[1] ACAD CTR DENT AMSTERDAM,DEPT DENT MAT SCI,1066 EA AMSTERDAM,NETHERLANDS
[2] TANTA UNIV,FAC DENT,DEPT OPERAT DENT,TANTA,EGYPT
关键词
adhesive dentistry; class I restorations; leakage; load cycling;
D O I
10.1016/0300-5712(95)00041-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to determine the effect of cycle loading on the sealing capacity of different adhesive systems in Class I restorations in vitro. Methods: (1) Clearfil Liner Bond/Clearfil Photo Posterior, (2) Scotchbond Multipurpose/Z100, (3) Syntac/Heliomolar, and (4) Gluma 2000/Pekalux were employed to restore Class I cavities in extracted human premolars and molars. For each test group, half of the specimens were subjected to mechanical loading at 125 N for 5000 cycles in a dye solution. After sectioning, dye penetration was assessed. Results: Without loading, no specimen showed leakage, while loading did affect the sealing capacity of groups 3 and 4. Groups 1 and 2 showed no significant increase in leakage after the loading procedure. Conclusion: The results indicate that mechanical cycle loading can adversely affect the interface of adhesive Class I resin composite restorations unless hybridizing adhesive systems are used.