Electrooxidation Behavior and Amperometric Determination of Sotalol on a Graphene Oxide Nanosheets-modified Glassy Carbon Electrode

被引:11
|
作者
Heli, Hossein [1 ]
Zare, Seyede Nasrin [2 ]
Sattarahmady, Naghmeh [3 ,4 ,5 ]
Karimian, Khashayar [6 ]
机构
[1] Iranian Space Res Ctr, Inst Mech, Shiraz 7155863333, Iran
[2] Islamic Azad Univ, Firouzabad Branch, Dept Chem, Firouzabad, Iran
[3] Shiraz Univ Med Sci, Sch Med, Dept Med Phys, Shiraz, Iran
[4] Shiraz Univ Med Sci, Sch Pharm, Pharmaceut Sci Res Ctr, Shiraz, Iran
[5] Shiraz Univ Med Sci, Sch Adv Med Sci & Technol, Dept Nanomed, Shiraz, Iran
[6] Arasto Pharmaceut Chem Inc, Tehran, Iran
基金
美国国家科学基金会;
关键词
Graphene; sotalol; modified electrode; electrocatalysis; nanosensor; SENSITIVE DETECTION; NANOCOMPOSITE; NANOPARTICLES; PLASMA; FIBRILLATION; OXIDATION; SENSOR;
D O I
10.2174/1573412911309030007
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The electrochemical behavior of sotalol was investigated on a graphene oxide nanosheets-modified glassy carbon electrode in a phosphate buffer solution, pH 7.4. Cyclic voltammetry and chronoamperometry were employed to obtain information about the electrooxidation process. During the electrooxidation of sotalol, one irreversible anodic peak appeared in the voltammograms. Some kinetic parameters, such as the diffusion and charge transfer coefficients were obtained. An amperometric procedure was developed for the determination of sotalol, a detection limit of 7.57 mu M, a linear dynamic range of 0.1 to 2.24 mM, and a calibration sensitivity of 0.945 mA M-1 were obtained. The method was applied to the analysis of sotalol tablets, and applicability of the method to direct assays of spiked human serum and urine fluids was investigated.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [11] A glassy carbon electrode modified with graphene oxide decorated silver phosphate nanodentrites for amperometric determination of dissolved hydrazine
    Karuppasamy, Kohila Rani
    Devasenathipathy, Rajkumar
    Wang, Sea-Fue
    MICROCHIMICA ACTA, 2017, 184 (08) : 2569 - 2577
  • [12] Copper oxide anchored polyaniline modified glassy carbon electrode: A new sensor platform for the Amperometric determination of Chlorpyrifos
    Sudharsan, Sundar
    Rajaram, Rajendran
    Kumar, Sachin
    Swaminathan, Parasuraman
    Ramanujam, Kothandaraman
    Neelakantan, Lakshman
    ELECTROCHIMICA ACTA, 2023, 471
  • [13] Electrochemical behavior and voltammetric determination of paracetamol on Nafion/TiO2-graphene modified glassy carbon electrode
    Fan, Yang
    Liu, Jin-Hang
    Lu, Hai-Ting
    Zhang, Qin
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 85 (02) : 289 - 292
  • [14] Electrochemical Determination of Nitrite Using a Reduced Graphene Oxide-Multiwalled Carbon Nanotube-Modified Glassy Carbon Electrode
    Deng, Keqin
    Zhou, Jianhong
    Huang, Haowen
    Ling, Yulin
    Li, Chunxiang
    ANALYTICAL LETTERS, 2016, 49 (18) : 2917 - 2930
  • [15] ELECTROCHEMICAL DETERMINATION OF ETHYL MALTOL ON A GLASSY CARBON ELECTRODE MODIFIED WITH GRAPHENE
    Chen, Meifeng
    Ma, Xinying
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2013, 58 (03): : 1918 - 1920
  • [16] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Sharma, Vimal
    Hynek, David
    Trnkova, Libuse
    Hemzal, Dusan
    Marik, Marian
    Kizek, Rene
    Hubalek, Jaromir
    MICROCHIMICA ACTA, 2016, 183 (04) : 1299 - 1306
  • [17] A cobalt oxide nanocubes interleaved reduced graphene oxide nanocomposite modified glassy carbon electrode for amperometric detection of serotonin
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Numan, Arshid
    Shahabuddin, Syed
    Alizadeh, Mandi
    Khiew, Poi Sim
    Chiu, Wee Siong
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 100 : 388 - 395
  • [18] Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide
    Lisnund, Sireerat
    Blay, Vincent
    Chansaenpak, Kantapat
    Pinyou, Piyanut
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7214 - 7227
  • [19] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Vimal Sharma
    David Hynek
    Libuse Trnkova
    Dusan Hemzal
    Marian Marik
    Rene Kizek
    Jaromir Hubalek
    Microchimica Acta, 2016, 183 : 1299 - 1306
  • [20] Voltammetric Determination of Bergenin with Graphene Modified Glassy Carbon Electrode
    Li, Xiaobao
    Zou, Ruyi
    Niu, Yanyan
    Shao, Taiming
    Chen, Yong
    Sun, Wei
    He, Mengxiong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (02): : 1976 - 1984