Analysis of polyaromatic quinones in a complex environmental matrix using gas chromatography ion trap tandem mass spectrometry

被引:21
|
作者
Mosi, AA
Reimer, KJ
Eigendorf, GK
机构
[1] UNIV BRITISH COLUMBIA,DEPT CHEM,VANCOUVER,BC V6T 1Z1,CANADA
[2] ROYAL MIL COLL CANADA,ENVIRONM SCI GRP,KINGSTON,ON K7K 5L0,CANADA
关键词
collision induced dissociation; environmental analysis; gas chromatography; ion trap; polycyclic aromatic hydrocarbons; polyaromatic quinones; tandem mass spectrometry;
D O I
10.1016/S0039-9140(96)02172-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
GC/MS and GC/MS/MS in a quadrupole ion trap were used to analyze for anthraquinone, alkyl anthraquinones, benz[a]anthracene-7,12-dione and 9-fluoranone in a sediment obtained from an aluminum smelter settling pond contaminated with polycyclic aromatic hydrocarbons. By standard GC/MS analysis many of these target compounds were either undetectable or their confirmation uncertain because of matrix interferences. Detection and identification were greatly improved by using GC/MS/MS. GC/MS/MS analyses were performed by selecting the molecular ion (M) of a target compound and fragmenting it via collision induced dissociation (CID) to yield product ions corresponding to loss of CO for unsubstituted compounds or CO plus CH3 for alkylated compounds. The CID conditions were optimized using anthraquinone and 2-methylanthraquinone standards by varying the CID excitation energy and RF storage levels to yield optimum amounts of fragment ions. CID experiments were performed using both resonant and non-resonant wave forms. Although both excitation techniques gave comparable results for the removal of matrix interferences, non-resonant excitation provided more characteristic spectra for the alkylated anthraquinones. Monitoring of secondary fragmentation products, such as M-2CO, provided greater discrimination from matrix interferences than the use of primary fragmentation products, such as M-CO. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:985 / 1001
页数:17
相关论文
共 50 条
  • [31] Simultaneous determination of polycyclic aromatic dydrocarbons and their nitrated derivatives in airborne particulate matter using gas chromatography-tandem mass spectrometry
    Nicol, S
    Dugay, J
    Hennion, MC
    JOURNAL OF SEPARATION SCIENCE, 2001, 24 (06): : 451 - 458
  • [32] Tandem pyrolysis evolved gas–gas chromatography–mass spectrometry
    Dwyer, Derek B. (dwyerdb@ornl.gov), 1600, Elsevier B.V. (186):
  • [33] Analysis of Dried Blood Spots for Polychlorinated Biphenyls and Organochlorine Pesticides by Gas Chromatography Coupled with Tandem Mass Spectrometry
    Provatas, Anthony A.
    Kolakowski, Steven L.
    Sternberg, Francis H.
    Stuart, James D.
    Perkins, Christopher R.
    ANALYTICAL LETTERS, 2019, 52 (09) : 1379 - 1395
  • [34] Trace analysis of benzene, toluene, ethylbenzene and xylene isomers in environmental samples by low-pressure gas chromatography - ion trap mass spectrometry
    Joos, PE
    Godoi, AFL
    De Jong, R
    de Zeeuw, J
    Van Grieken, R
    JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) : 191 - 196
  • [35] Analysis of organometallic compounds using ion trap mass spectrometry
    Dyson, PJ
    McIndoe, JS
    INORGANICA CHIMICA ACTA, 2003, 354 : 68 - 74
  • [36] Optimization and application of high-resolution gas chromatography with ion trap tandem mass spectrometry to the determination of polychlorinated biphenyls in atmospheric aerosols
    Mandalakis, M
    Tsapakis, M
    Stephanou, EG
    JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) : 183 - 196
  • [37] Gas chromatography positive chemical ionization and tandem mass spectrometry for the analysis of organic high explosives
    Perr, JM
    Furton, KG
    Almirall, JR
    TALANTA, 2005, 67 (02) : 430 - 436
  • [38] Analysis of steroids in urine by gas chromatography-capillary photoionization-tandem mass spectrometry
    Poho, Paivi
    Scholz, Karen
    Karkkanen, Niina
    Haapala, Markus
    Raikkonen, Heikki
    Kostiainen, Risto
    Vaikkinen, Anu
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1598 : 175 - 182
  • [39] Strategies for the analysis of chlorobenzenes in soils using solid-phase microextraction coupled with gas chromatography ion trap mass spectrometry.
    Sarrión, MN
    Santos, FJ
    Galceran, MT
    JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) : 197 - 209
  • [40] Neurosteroid analysis by gas chromatography-atmospheric pressure photoionization-tandem mass spectrometry
    Suominen, Tina
    Haapala, Markus
    Takala, Anna
    Ketola, Raimo A.
    Kostiainen, Risto
    ANALYTICA CHIMICA ACTA, 2013, 794 : 76 - 81