Relationship between CT intensity, micro-architecture and mechanical properties of porcine vertebral cancellous bone

被引:105
|
作者
Teo, JCM [1 ]
Si-Hoe, KM [1 ]
Keh, JEL [1 ]
Teoh, SH [1 ]
机构
[1] Natl Univ Singapore, Dept Mech Engn, Ctr Biomed Mat Applicat & Technol, Singapore 117576, Singapore
关键词
bone micro-architecture; bone mechanical properties; cancellous bone; micro-CT; porcine bone;
D O I
10.1016/j.clinbiomech.2005.11.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background In vivo assessment of bone density is insufficient for the evaluation of osteoporosis in patients. A more complete diagnostic tool for the determination of bone quality is needed. Micro-computed tomography imaging allows a non-destructive method for evaluating cancellous bone micro-architecture. However, lengthened exposure to ionizing radiation prevents patients to be imaged by such a system. The aim for this study was to elucidate the relationships between image intensity (of Hounsfield units), cancellous bone micro-architecture and mechanical properties. Methods. Using pig vertebral cancellous bone, the bone specimens were imaged using clinical and micro-computed tomography scanners and subsequently subjected to uniaxial compression testing. Results. Results indicate that micro-architecture can be predicted using clinical image intensity. Micro-architectural parameters relevant to osteoporosis study, such as percent bone volume, trabecular bone pattern factor, structure model index, trabecular thickness and trabecular separation have shown significant correlation with R-2 values of 0.83, 0.80, 0.70, 0.72, and 0.54, respectively, when correlated to Hounsfield units. In addition, the correlation of mechanical properties (E, sigma(yield), and sigma(ult)) in the superior-inferior direction (the primary loading direction), to micro-architecture parameters has also been good (R-2 > 0.5) for all except tissue volume, tissue surface and degree of anisotropy. Interpretation. This proves that the predictive power of bone strength and stiffness was improved with the combination of bone density and micro-architecture information. This work supports the prediction of micro-architecture using current clinical computed tomography imaging technology. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:235 / 244
页数:10
相关论文
共 50 条
  • [21] Mechanical properties of vertebral trabeculae with ageing evaluated with micro-CT
    Gong, He
    Zhang, Ming
    Qin, Ling
    ADVANCED BIOIMAGING TECHNOLOGIES IN ASSESSMENT OF THE QUALITY OF BONE AND SCAFFOLD MATERIALS: TECHNIQUES AND APPLICATIONS, 2007, : 463 - +
  • [22] A MODEL OF VERTEBRAL TRABECULAR BONE ARCHITECTURE AND ITS MECHANICAL-PROPERTIES
    JENSEN, KS
    MOSEKILDE, L
    MOSEKILDE, L
    BONE, 1990, 11 (06) : 417 - 423
  • [23] Mechanical properties of adult vertebral cancellous bone: Correlation with collagen intermolecular cross-links
    Banse, X
    Sims, TJ
    Bailey, AJ
    JOURNAL OF BONE AND MINERAL RESEARCH, 2002, 17 (09) : 1621 - 1628
  • [24] Correlation of cancellous bone microarchitectural parameters from microCT to CT number and bone mechanical properties
    Teo, J. C. M.
    Si-Hoe, K. M.
    Keh, J. E. L.
    Teoh, S. H.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2007, 27 (02): : 333 - 339
  • [25] RELATIONSHIP BETWEEN STRUCTURE AND MECHANICAL RESONANCE-SPECTRA IN HUMAN CANCELLOUS BONE
    PUGH, JW
    STEINER, GC
    MEDICAL & BIOLOGICAL ENGINEERING, 1975, 13 (05): : 714 - 716
  • [26] Relationship between skin-collagen micro-architecture and ultrasonic backscatter parameters at 20 MHz
    Fournier, C
    Bridal, SL
    Coron, A
    Laugier, P
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 625 - 628
  • [27] Remodelling of vertebral endplate subchondral bone in scoliosis: A micro-CT analysis in a porcine model
    Laffosse, Jean-Michel
    Accadbled, Franck
    Bonnevialle, Nicolas
    Gomez-Brouchet, A.
    de Gauzy, Jerome Sales
    Swider, Pascal
    CLINICAL BIOMECHANICS, 2010, 25 (07) : 636 - 641
  • [28] Quantitative Characterization of Trabecular Bone Micro-architecture Using Tensor Scale and Multi-Detector CT Imaging
    Liu, Yinxiao
    Saha, Punam K.
    Xu, Ziyue
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 124 - 131
  • [29] Dependence of mechanical compressive strength on local variations in micro architecture in cancellous bone of proximal human femur
    Perilli, E.
    Baleani, M.
    Ohman, C.
    Fognani, R.
    Baruffaldi, F.
    Viceconti, M.
    JOURNAL OF BIOMECHANICS, 2008, 41 (02) : 438 - 446
  • [30] BONE MINERAL DENSITY, SPINAL MICRO-ARCHITECTURE (TBS DATA) AND BODY COMPOSITION IN THE OLDER UKRAINIAN WOMEN WITH VERTEBRAL FRAGILITY FRACTURES
    Povoroznyuk, V. V.
    Dzerovych, N. I.
    Povoroznyuk, R. V.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 : S717 - S717