A novel evaporative cooling system with a polymer hollow fibre spindle

被引:39
|
作者
Chen, Xiangjie [1 ,3 ]
Su, Yuehong [1 ]
Aydin, Devrim [4 ]
Ding, Yate [1 ]
Zhang, Shihao [1 ]
Reay, David [2 ]
Riffat, Saffa [1 ]
机构
[1] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2JQ, England
[2] David Reay & Associates, Whitley Bay, England
[3] Univ Shanghai Sci & Technol, Dept Energy & Power Engn, Jungong Rd 516, Shanghai 200031, Peoples R China
[4] Eastern Mediterranean Univ, Dept Mech Engn, TRNC Mersin 10, G Magosa, Turkey
基金
“创新英国”项目;
关键词
Polymer hollow fibre; Spindle shape; Evaporative cooling; Heat transfer; Mass transfer; Experiment; MASS-TRANSFER; COUNTER-FLOW; MEMBRANE MODULE; AIR HUMIDIFICATION; HEAT-EXCHANGERS; PERFORMANCE; COOLER;
D O I
10.1016/j.applthermaleng.2018.01.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
A polymer hollow fibre evaporative cooling system with a novel configuration of fibre bundle is proposed. With the aim to avoid the flow channelling or shielding of adjacent fibres the fibres inside each bundle were made into a spindle shape to maximize contact between the air stream and the fibres. For the porous wall of hollow fibre, the vapour of evaporated water can permeate through it effectively, while the liquid water droplets can be prevented from mixing with the processed air. For various dry bulb temperatures (27 degrees C, 30 degrees C, 33 degrees C, 36 degrees C and 39 degrees C) and relative humidity (23%, 32% and 40%) of the inlet air, the cooling performances of the proposed novel evaporative cooling system were experimentally investigated. The variations of outlet air dry bulb temperature, wet bulb effectiveness, dew point effectiveness and cooling capacity with respect to different incoming air dry bulb temperature were studied. The effects of various incoming air Reynolds number on the heat and mass transfer coefficients, heat flux and mass flux across the polymer hollow fibre module were analysed. Experimentally derived non dimensional heat and mass transfer correlations were compared with other correlations from literature. Due to the proposed spindle shape of hollow fibre bundle, the shielding between adjacent fibres could be mitigated greatly, therefore the heat and mass transfer performance of the proposed system demonstrated significant improvement compared with other designs reported in literature. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:665 / 675
页数:11
相关论文
共 50 条
  • [21] Efficiency Analysis of a Two-Stage Evaporative Cooling System with Sustainable Water Pad
    Salman, Ameer Hayder
    Jasim, Jasim Ahmed
    Aljuboori, Mohammed Khudhair Alwan
    Zaidan, Ayad Awad
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2024, 42 (02) : 679 - 687
  • [22] An experimental study of a novel dew point evaporative cooling tower based on M-cycle
    Fan, Xuchen
    Lu, Xiaofeng
    Nie, Hua
    Zhu, Hancheng
    Wang, Quanhai
    Kang, Yinhu
    Liu, Shuwei
    Zheng, Xiong
    Liu, Zhuo
    Zhang, Yi
    Long, Xiaofei
    Li, Jianbo
    APPLIED THERMAL ENGINEERING, 2021, 190
  • [23] Exergoeconomic analysis of a solar photovoltaic-based direct evaporative air-cooling system
    Kiyaninia, Alireza
    Karimi, Hajir
    Avargani, Vahid Madadi
    SOLAR ENERGY, 2019, 193 : 253 - 266
  • [24] Thermodynamic analysis of a hybrid membrane liquid desiccant dehumidification and dew point evaporative cooling system
    Lin, Jie
    Huang, Si-Min
    Wang, Ruzhu
    Chua, Kian Jon
    ENERGY CONVERSION AND MANAGEMENT, 2018, 156 : 440 - 458
  • [25] A novel M-cycle evaporative cooling vest for enhanced comfort of active human in hot environment
    Raad, Ragheb
    Itani, Mariam
    Ghaddar, Nesreen
    Ghali, Kamel
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 142 : 1 - 13
  • [26] Evaluating the viability and performance enhancement of Ensete ventricosum fibre pads in evaporative cooling system
    Beyene E.G.
    Anjulo M.A.
    Ayenew D.B.
    International Journal of Ambient Energy, 2024, 45 (01)
  • [27] The performance and model of porous materials in the indirect evaporative cooling system: A review
    Lv, Jing
    Xu, Haodong
    Zhu, Mengya
    Dai, Yuwei
    Liu, Hongzhi
    Li, Zhao
    JOURNAL OF BUILDING ENGINEERING, 2021, 41
  • [28] Experimental study on the performance of a novel hybrid indirect evaporative cooling/thermoelectric cooling system
    Zhou Y.
    Yan Z.
    Dai Q.
    Yu Y.
    Building and Environment, 2022, 207
  • [29] Numerical modeling of ventilated wall cavities with spray evaporative cooling system
    Alaidroos, Alaa
    Krarti, Moncef
    ENERGY AND BUILDINGS, 2016, 130 : 350 - 365
  • [30] Experimental study of an ultrasonic regenerative evaporative cooler for a desiccant cooling system
    Arun, B. S.
    Mariappan, V.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2019, 40 (02) : 151 - 175