Single-Incision Transaxillary Robotic Thyroidectomy: Challenges and Limitations in a North American Population

被引:20
|
作者
Lin, Ho-Sheng [1 ,2 ,3 ]
Folbe, Adam J. [1 ,2 ]
Carron, Michael A. [1 ,2 ,3 ]
Zuliani, Giancarlo F. [1 ,2 ,3 ]
Chen, Wei [4 ]
Yoo, George H. [1 ,2 ]
Mathog, Robert H. [1 ,2 ]
机构
[1] Wayne State Univ, Dept Otolaryngol Head & Neck Surg, Detroit, MI 48201 USA
[2] Karmanos Canc Inst, Detroit, MI USA
[3] John D Dingell VA Med Ctr, Dept Surg, Detroit, MI USA
[4] Wayne State Univ, Dept Oncol, Karmanos Canc Inst, Biostat Core, Detroit, MI 48201 USA
关键词
thyroid surgery; robotic thyroidectomy; transaxillary; thyroid; GASLESS ENDOSCOPIC THYROIDECTOMY; VIDEO-ASSISTED THYROIDECTOMY; AXILLARY APPROACH; BREAST APPROACH; EXPERIENCE; SURGERY;
D O I
10.1177/0194599812461610
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective. We reviewed our initial experience with robotic thyroidectomy to identify challenges and limitations of this new surgical approach when applied to a North American population. Study Design. Case series. Setting. Academic institution. Subjects/Methods. Retrospective review of 18 consecutive robotic thyroid lobectomies performed from February 2010 to April 2012 involving 16 female patients. Two patients underwent robot-assisted completion thyroidectomy a few months following the initial thyroid surgery, one for cancer and the other for goiter. Results. Median age was 47.5 years (range, 18-62 years), and median body mass index was 28.7 (range, 19.4-44.5). Median thyroid nodule size was 2.9 cm (range, 1.1-4.7 cm). All but 1 case (6%) was performed successfully via single axillary incision. There was no conversion to an open approach. Median operative time was 170 minutes (range, 95-220 minutes), and median blood loss was 12.5 mL (range, 5-75 mL). Complications occurred in 4 cases (22%) to include temporary vocal cord pareses (n = 3) and a postoperative hematoma that required exploration. Median hospital stay was 2 days (range, 1-3 days). Conclusion. Single-incision transaxillary robotic thyroidectomy can be technically challenging in North American patients with a larger body frame due to difficulty in optimal placement of all 4 robotic instruments via a single axillary incision. All 3 cases of temporary vocal cord paresis occurred early in our experience and may have been due to our relative inexperience with this new approach and associated instrumentation. Other limitations include less than optimal visualization of the recurrent laryngeal nerve in the contralateral lobe as well as poor access to the substernal region.
引用
收藏
页码:1041 / 1046
页数:6
相关论文
共 50 条
  • [41] Transaxillary gasless robotic thyroid surgery with nerve monitoring: Initial two experince in a North American center
    Kandil, Emad
    Winters, Ryan
    Aslam, Rizwan
    Friedlander, Paul
    Bellows, Charles
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2012, 21 (02) : 90 - 95
  • [42] Pediatric Single-Incision Robotic Cholecystectomy: A 6-Year Update from a Single Institution
    Hey, Matthew T.
    Mayhew, Mackenzie
    Rico, Stephani
    Calisto, Juan
    Shaffiey, Shahab
    Malvezzi, Leopoldo
    Alkhoury, Fuad
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2023, 33 (07): : 698 - 702
  • [43] Single-Incision vs. Multiport Robotic Sacrocolpopexy: 126 Consecutive Cases at a Single Institution
    Nam, Gina
    Lee, Sa-Ra
    Roh, A-mi
    Kim, Ju-Hee
    Choi, Sungwook
    Kim, Sung-Hoon
    Chae, Hee-Dong
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (19)
  • [44] Robotic Single-Incision Transumbilical Total Hysterectomy Using a Single-Site Robotic Platform: Initial Report and Technique
    Sendag, Fatih
    Akdemir, Ali
    Oztekin, Mehmet Kemal
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2014, 21 (01) : 147 - 151
  • [45] A Comprehensive Analysis of Single-Incision Laparoscopic Cholecystectomy: Trends, Challenges, and Future Directions
    Morcos, Rami Kamal Atiya
    Lima, Sergio Rodrigo Oliveira Souza
    Bokhari, Syed Faqeer Hussain
    Almadhoun, Mohammed Khaleel I. K. H.
    Patel, Mitwa
    Hlyan, Nay Phone
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [46] Transoral thyroidectomy and parathyroidectomy - A North American series of robotic and endoscopic transoral approaches to the central neck
    Russell, Jonathon O.
    Clark, James
    Noureldine, Salem I.
    Anuwong, Angkoon
    Al Khadem, Mai G.
    Kim, Hoon Yub
    Dhillon, Vaninder K.
    Dionigi, Gianlorenzo
    Tufano, Ralph P.
    Richmon, Jeremy D.
    ORAL ONCOLOGY, 2017, 71 : 75 - 80
  • [47] Application of a commercial single-port device for robotic single-incision distal pancreatectomy: initial experience
    Peng, Cheng-Ming
    Liu, Hsin-Cheng
    Hsieh, Ching-Lung
    Yang, Yao-Kun
    Cheng, Teng-Chieh
    Chou, Ruey-Hwang
    Liu, Yi-Jui
    SURGERY TODAY, 2018, 48 (07) : 680 - 686
  • [48] Comparative study of robotic-assisted single-incision-plus-one port and single-incision laparoscopic choledochal cyst excision
    Zhang, Ling
    Chen, Shan
    Lin, Yang
    Wang, Jianbin
    Qiu, Xinyi
    Li, Lizhi
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [49] The learning curve for single-port transaxillary robotic thyroidectomy (SP-TART): experience through initial 50 cases of lobectomy
    Park, Joonseon
    Kang, Il Ku
    Kim, Kwangsoon
    Bae, Ja Seong
    Kim, Jeong Soo
    UPDATES IN SURGERY, 2023, 75 (03) : 691 - 700
  • [50] Challenges and strategies for single-incision laparoscopic Roux-en-Y hepaticojejunostomy in managing giant choledochal cysts
    Diao, Mei
    Li, Long
    Li, Qi
    Ye, Mao
    Cheng, Wei
    INTERNATIONAL JOURNAL OF SURGERY, 2014, 12 (05) : 412 - 417