Converter non-integral harmonics from ac network resonating with ac network

被引:0
|
作者
Tang, LX [1 ]
Ooi, BT [1 ]
机构
[1] McGill Univ, Dept Elect & Comp Engn, Montreal, PQ H3A 2A7, Canada
来源
CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4 | 2001年
关键词
Total Harmonic Distortion; THD; Voltage-Source Converter; VSC; resonance; harmonics; ac network and dc network interaction;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Integral harmonics come from the switching pattern of the modulation method. Non-integral harmonics, on the other hand, are initiated by random noise that becomes amplified and sustained by the ac network resonating with the do network. A comprehensive theory of their origins is presented. Its correctness is justified by digital simulations. It is then shown that an efficient method of predicting their potential occurrences is by eigenvalue analysis. The objective of THD compliance can be met by: (i) avoidance by design of network parameters; (ii) suppression by active filtering. Some directions of parameter design are given. A simulation result is presented showing that an active filtering method is promising.
引用
收藏
页码:2186 / 2192
页数:7
相关论文
共 50 条
  • [1] Neural network based control of AC-AC converter for voltage sags, harmonics and EMI reduction
    Gulez, Kayhan
    Aliskan, Ibrahim
    Mumcu, T. Veli
    Cansever, Galip
    ADVANCED INTELLIGENT COMPUTING THEORIES AND APPLICATIONS: WITH ASPECTS OF THEORETICAL AND METHODOLOGICAL ISSUES, 2007, 4681 : 534 - +
  • [2] ANALYSIS OF THE OUTPUT SIGNAL HARMONICS IN A NON-LINEAR ELECTROMAGNETIC AC NETWORK
    HINOVA, I
    SAPAREW, S
    WITSCHEW, S
    ARCHIV FUR ELEKTROTECHNIK, 1979, 61 (05): : 303 - 307
  • [3] PQ and EMC Problems from The Connection at The Supplying Network induced by an AC-DC-AC Converter
    Nicolae, Petre-Marian
    Popa, Dinut-Lucian
    Nicolae, Marian-Stefan
    Nicolae, Ileana-Diana
    2014 IEEE 16TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2014, : 107 - 111
  • [4] Reducing Emissions from an AC-DC-AC Converter to Improve Power Delivery Network Behavior
    Nicolae, Petre-Marian
    Nicolae, Ileana-Diana
    Mihai, George
    Patru, Ion
    2014 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC), 2014, : 138 - 143
  • [5] AC-DC AND AC-AC CONVERTER CONTROL WITH SELECTIVE REDUCTION OF LINE HARMONICS
    KRISHNAMURTHY, KA
    REVANKAR, GN
    DUBEY, GK
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1978, 125 (11): : 1269 - 1270
  • [6] Neural network based switching control of AC-AC converter with DC-AC inverter for voltage sags, harmonics and EMI reduction using hybrid filter topology
    Gulez, Kayhan
    SIMULATION MODELLING PRACTICE AND THEORY, 2008, 16 (06) : 597 - 612
  • [7] Delta AC/AC Converter for Three-port Flexible Interconnection of Distribution Network
    Zhang G.
    Pei W.
    Shen L.
    Li N.
    Deng W.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (08): : 32 - 40
  • [8] Network topology and operation control of DC distribution network with AC DC converter
    Jing, Guoxiu
    Zhang, Aimin
    Zhang, Hang
    Sun, Shuai
    PROCEEDINGS OF THE 2019 31ST CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2019), 2019, : 6216 - 6220
  • [9] Non-Integral AC Capacitor Voltage Calculation Method for Shunt Hybrid Active Power Filter
    Lee, Hyunjae
    Shon, Jingeun
    IEEE ACCESS, 2023, 11 : 67968 - 67978
  • [10] AC-DC Converter with Asymmetrical Higher Harmonics Compensation Function in Sustainable AC Grid
    Wrona, Grzegorz
    Jasinski, Marek
    ELECTRICAL CONTROL AND COMMUNICATION ENGINEERING, 2013, 2 (01) : 5 - 13