Murine-specific Internal Dosimetry for Preclinical Investigations of Imaging and Therapeutic Agents

被引:13
作者
Bednarz, Bryan [1 ]
Grudzinski, Joseph [1 ]
Marsh, Ian [1 ]
Besemer, Abby [1 ,2 ]
Baiu, Dana [3 ]
Weichert, Jamey [4 ]
Otto, Mario [3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Human Oncol, Madison, WI 53705 USA
[3] Univ Wisconsin, Dept Pediat, Madison, WI 53705 USA
[4] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
来源
HEALTH PHYSICS | 2018年 / 114卷 / 04期
关键词
dosimetry; internal; Monte Carlo; nuclear medicine; radiation therapy; MONTE-CARLO SIMULATIONS; VOXEL-BASED MOUSE; S-VALUES; AUTOMATED SEGMENTATION; PHANTOM; MODEL; UNCERTAINTIES; ACCURACY; GEANT4; IMPACT;
D O I
10.1097/HP.0000000000000789
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
There is a growing need to estimate the absorbed dose to small animals from preclinical investigations involving diagnostic and therapeutic radiopharmaceuticals. This paper introduces a Monte Carlo-based dosimetry platform called RAPID, which is capable of calculating murine-specific three-dimensional (3D) dose distributions. A comparison is performed between absorbed doses calculated with RAPID and absorbed doses calculated in a commonly used reference mouse phantom called MOBY. Four test mice containing different xenografts underwent serial PET/CT imaging using a novel diagnostic therapy (theranostic) agent NM404, which can be labeled with I-124 for imaging or I-131 for therapy. Using the PET/CT data, 3D dose distributions from I-131-NM404 were calculated in the mice using RAPID. Mean organ doses in these four test mice were compared to mean organ doses derived by using two previously published I-131 S-values datasets in MOBY. In addition, mean tumor doses calculated in RAPID were compared to mean organ doses derived from unit density spheres. Large differences were identified between mean organ doses calculated in the test mice using RAPID and those derived in the MOBY phantom. Mean absorbed dose percent errors in organs ranged between 0.3% and 333%. Overall, mass scaling improved agreement between MOBY phantom calculations and RAPID, where percent errors were all less than 26%, with the exception of the lung in which percent errors reached values of 48%. Percent errors in mean tumor doses in the test mice and unit density spheres were less pronounced but still ranged between 8% and 23%. This work demonstrates the limitations of using pre-computed S-values in computational phantoms to predict organ doses in small animals from theranostic procedures. RAPID can generate accurate 3D dose distributions in small animals and in turn offer much greater insight on the ability of a given theranostic agent to image and treat diseases.
引用
收藏
页码:450 / 459
页数:10
相关论文
共 38 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Absorbed fractions in ellipsoidal volumes for β- radionuclides employed in internal radiotherapy [J].
Amato, E. ;
Lizio, D. ;
Baldari, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (13) :4171-4180
[3]   Dosimetric accuracy of planning and delivering small proton therapy fields [J].
Bednarz, Bryan ;
Daartz, Juliane ;
Paganetti, Harald .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (24) :7425-7438
[4]  
Besemer A, 2014, MED PHYS, V41, P303, DOI 10.1118/1.4888678
[5]   Evaluation of Dosimetric Uncertainties in Individualized Targeted Radionuclide Therapy (TRT) Treatment Planning Using Pre-Clinical Data [J].
Besemer, A. ;
Grudzinski, J. ;
Titz, B. ;
Bednarz, J. B. .
MEDICAL PHYSICS, 2015, 42 (06) :3675-3675
[6]   The clinical impact of uncertainties in the mean excitation energy of human tissues during proton therapy [J].
Besemer, Abigail ;
Paganetti, Harald ;
Bednarz, Bryan .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) :887-902
[7]  
Bhat M.R., 1992, Evaluated Nuclear Structure Data File (ENSDF)
[8]  
Bitar A, 2007, Q J NUCL MED MOL IM, V51, P343
[9]   A voxel-based mouse for internal dose calculations using Monte Carlo simulations (MCNP) [J].
Bitar, A. ;
Lisbona, A. ;
Thedrez, P. ;
Maurel, C. Sai ;
Le Forestier, D. ;
Barbet, J. ;
Bardies, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (04) :1013-1025
[10]   The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy [J].
Faddegon, Bruce A. ;
Kawrakow, Iwan ;
Kubyshin, Yuri ;
Perl, Joseph ;
Sempau, Josep ;
Urban, Laszlo .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20) :6151-6163