摘要
Purpose: To investigate the effect of the range of TE on multi-echo gradient echobased myelin water fraction (MWF) mapping at 3 T. Methods: Myelin water fraction estimation was performed using 3 widely used models: magnitude multipool, magnitude 3-pool, and complex 3-pool model. Simulations were conducted using a hollow cylinder model with susceptibility anisotropy. The TE range was varied, and its effect on MWF estimation was observed. The same analysis was also performed with in vivo data from 4 healthy volunteers. Results: Different MWFs were obtained depending on the range of TE data acquired. In the simulations, the results of both magnitude models had a bias with respect to the true values: a maximum bias of up to 20% for the multipool model, and a maximum bias of up to 8% for the 3-pool model. This bias was reduced using the complex 3-pool model (maximum bias was under 2%). These effects were also found in the in vivo data. The MWF values using the complex model was most stable with respect to the TE range. Conclusion: The results of the simulation and in vivo data suggest that MWF values fitted using magnitude models are more influenced by the TE range collected for fitting than using the complex model. The complex model is helpful in mitigating bias due to dependencies over the TE range selection.
引用
收藏
页码:2799 / 2807
页数:9
相关论文
共 50 条
  • [1] Myelin water fraction mapping with joint inversion of gradient-echo and spin-echo data
    Dega, Segolene
    Ferreira, Monica
    Veldmann, Marten
    Stirnberg, Ruediger
    Paasche, Hendrik
    Stoecker, Tony
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2025, 38 (02): : 317 - 332
  • [2] Advances in gradient echo myelin water imaging at 3T and 7T
    Shin, Hyeong-Geol
    Oh, Se-Hong
    Fukunaga, Masaki
    Nam, Yoonho
    Lee, Doohee
    Jung, Woojin
    Jo, Minju
    Ji, Sooyeon
    Choi, Joon Yul
    Lee, Jongho
    NEUROIMAGE, 2019, 188 : 835 - 844
  • [3] Short echo-time 3D radial gradient-echo MRI using concurrent dephasing and excitation
    Park, Jang-Yeon
    Moeller, Steen
    Goerke, Ute
    Auerbach, Edward
    Chamberlain, Ryan
    Ellermann, Jutta
    Garwood, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 428 - 436
  • [4] Improved Multi-Echo Gradient-Echo-Based Myelin Water Fraction Mapping Using Dimensionality Reduction
    Song, Jae Eun
    Kim, Dong-Hyun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (01) : 27 - 38
  • [5] Physiological noise compensation in gradient-echo myelin water imaging
    Nam, Yoonho
    Kim, Dong-Hyun
    Lee, Jongho
    NEUROIMAGE, 2015, 120 : 345 - 349
  • [6] Blind Source Separation for Myelin Water Fraction Mapping Using Multi-Echo Gradient Echo Imaging
    Song, Jae Eun
    Shin, Jaewook
    Lee, Hongpyo
    Lee, Ho Joon
    Moon, Won-Jin
    Kim, Dong-Hyun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 2235 - 2245
  • [7] Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T
    Xu, Guojun
    Zhao, Zhiyong
    Zhu, Qinfeng
    Zhu, Keqing
    Zhang, Jing
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 803 - 813
  • [8] Artificial neural network for multi-echo gradient echo-based myelin water fraction estimation
    Jung, Soozy
    Lee, Hongpyo
    Ryu, Kanghyun
    Song, Jae Eun
    Park, Mina
    Moon, Won-Jun
    Kim, Dong-Hyun
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 394 - 403
  • [9] Improved three-dimensional multi-echo gradient echo based myelin water fraction mapping with phase related artifact correction
    Lee, Hongpyo
    Nam, Yoonho
    Lee, Ho-Joon
    Hsu, Jung-Jiin
    Henry, Roland G.
    Kim, Dong-Hyun
    NEUROIMAGE, 2018, 169 : 1 - 10
  • [10] Multi-gradient-echo myelin water fraction imaging: Comparison to the multi-echo-spin-echo technique
    Alonso-Ortiz, Eva
    Levesque, Ives R.
    Pike, G. Bruce
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1439 - 1446