Design of zeolite boiler in thermochemical energy storage and transport system utilizing unused heat from sugar mill

被引:14
作者
Fujii, Shoma [1 ]
Horie, Naoyuki [1 ]
Nakaibayashi, Ko [1 ]
Kanematsu, Yuichiro [2 ]
Kikuchi, Yasunori [2 ]
Nakagaki, Takao [1 ]
机构
[1] Waseda Univ, Dept Modern Mech Engn, Shinjuku Ku, 3-4-1 Okubo, Tokyo 1698555, Japan
[2] Univ Tokyo, Presidential Endowed Chair Platinum Soc, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
关键词
Adsorption equilibrium; Moving bed; Sugarcane bagasse; Biomass; Renewables; Thermal energy storage; FLUID DISPERSION COEFFICIENTS; WATER-VAPOR ADSORPTION; LIFE-CYCLE ASSESSMENT; NUMERICAL INVESTIGATIONS; WASTE HEAT; PACKED-BEDS; GENERATION; REACTOR; BAGASSE; TES;
D O I
10.1016/j.apenergy.2019.01.104
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In Tanegashima, an isolated island in Japan, a 1500 ton/day sugar mill produces raw sugar and residual bagasse simultaneously. The bagasse is burned to generate steam that drives power turbines, but the bagasse boiler burns more bagasse than that is required. Accordingly, the process has a high temperature flue gas and a sizeable amount of unused heat at around 200 degrees C is exhausted from the sugar mill. Conversely, many other factories on the island burn imported oil in package boilers to generate process steam at temperatures up to 120 degrees C, all year around. To resolve this spatial and seasonal mismatch, we employ a thermochemical energy storage and transport system that uses a zeolite steam adsorption and desorption cycle. We introduce a basic design of a heat discharging device (a "zeolite boiler") that features a moving bed with an indirect heat exchanger. The zeolite boiler's performance is predicted by an in house designed simulation model that includes empirical equilibrium adsorption kinetics and a heat transfer model of the exotherm for zeolite 13X adsorbing water vapor. The effects of the mass flow rates of zeolite and injected steam are computed and suggest that optimal conditions to produce 800 kg/h of steam could decrease fuel consumption by the existing oil-fired package boiler of 23.2%. We then design an advanced zeolite boiler to recover the zeolite's sensible heat, which would otherwise be wasted. Employing this economizing process yielded a total decrease in fuel consumption of 29.6%.
引用
收藏
页码:561 / 571
页数:11
相关论文
共 47 条
[1]  
Annex 18-ECES IA-IEA, 2010, 18ECES IAIEA
[2]  
Basu P, 2010, BIOMASS GASIFICATION
[3]   A Comparison of Various Technological Options for Improving Energy and Water Use Efficiency in a Traditional Sugar Mill [J].
Birru, Eyerusalem ;
Erlich, Catharina ;
Herrera, Idalberto ;
Martin, Andrew ;
Feychting, Sofia ;
Vitez, Marina ;
Abdulhadi, Emma Bednarcik ;
Larsson, Anna ;
Onoszko, Emanuel ;
Hallersbo, Mattias ;
Weilenmann, Louise ;
Puskoriute, Laura .
SUSTAINABILITY, 2016, 8 (12)
[4]  
Bonk S., 2017, P ISES SOL WORLD C
[5]   CO2 mitigation accounting for Thermal Energy Storage (TES) case studies [J].
Cabeza, Luisa F. ;
Miro, Laia ;
Oro, Eduard ;
de Gracia, Alvaro ;
Martin, Viktoria ;
Kroenauer, Andreas ;
Rathgeber, Christoph ;
Farid, Mohammed M. ;
Paksoy, Halime O. ;
Martinez, Monica ;
Ines Fernandez, A. .
APPLIED ENERGY, 2015, 155 :365-377
[6]   Industrial surplus heat transportation for use in district heating [J].
Chiu, J. N. W. ;
Flores, J. Castro ;
Martin, V. ;
Lacarriere, B. .
ENERGY, 2016, 110 :139-147
[7]  
Dan E, 2001, ACEEES 2001 SUMM STU
[8]  
de Boer R, 2014, EUR SEM 99 ADV THERM
[9]   Economic-energy-environment analysis of prospective sugarcane bioethanol production in Brazil [J].
de Carvalho, Ariovaldo Lopes ;
Antunes, Carlos Henggeler ;
Freire, Fausto .
APPLIED ENERGY, 2016, 181 :514-526
[10]   THEORETICAL PREDICTION OF EFFECTIVE HEAT-TRANSFER PARAMETERS IN PACKED-BEDS [J].
DIXON, AG ;
CRESSWELL, DL .
AICHE JOURNAL, 1979, 25 (04) :663-676