Analysis of Parameter Effects on the Small-Signal Dynamics of Buck Converters with Average Current Mode Control

被引:9
作者
Li, Ruqi [1 ]
O'Brien, Tony [1 ]
Lee, John
Beecroft, John
Hwang, Kenny
机构
[1] Cisco Inc, Serv Routing Technol Grp, San Jose, CA USA
关键词
Average current mode control; Buck converters; Parameters effects; Small signal average models;
D O I
10.6113/JPE.2012.12.3.399
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In DC-DC Buck converters with average current mode control, the current loop compensator provides additional design freedom to enhance the converter current loop performance. On the other hand, the current loop circuit elements append substantial amount of complexity to not only the inner current loop but also the outer voltage loop, which makes it demanding to quantify circuit and operating parameter effects on the small-signal dynamics of such converters. Despite the difficulty, it is shown in this paper that parameter effects can be analyzed satisfactorily by using an existing small-signal model in conjunction with a newly proposed simplified alternative. As a result of the study, new insight into average current mode control is uncovered and discussed quantitatively. Measurable experimental results on a prototype averaged-current-mode-controlled Buck converter are provided to facilitate the analytical study with good correlation.
引用
收藏
页码:399 / 409
页数:11
相关论文
共 10 条
[1]  
Cooke P., 2000, Applied Power Electronics Conference and Exposition, V1,, P256
[2]  
Dixon L. H., 1990, UN TEX INSTR POW SUP
[3]  
Erickson R.W., 2007, Fundamentals of power electronics
[4]   Modeling Average-Current-Mode-Controlled Multi-Phase Buck Converters [J].
Li, Ruqi .
2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, :3299-3305
[5]  
Middlebrook R. D., 1987, IEEE Transactions on Power Electronics, VPE-2, P109, DOI 10.1109/TPEL.1987.4766345
[6]   A New, Continuous-Time Model For Current-Mode Control [J].
Ridley, Raymond B. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1991, 6 (02) :271-280
[7]  
Ruqi Li, 2009, Proceedings of the 2009 IEEE Energy Conversion Congress and Exposition. ECCE 2009, P647, DOI 10.1109/ECCE.2009.5316523
[8]   Modeling and practical design issues for average current control [J].
Sun, J ;
Bass, RM .
APEC'99: FOURTEENTH ANNUAL APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, CONFERENCE PROCEEDINGS, VOLS 1 & 2, 1999, :980-986
[9]  
Suntio T, 2001, IEEE POWER ELECTRON, P1259
[10]  
Tang W., 1993, IEEE Transactions on Power Electronics, V8, P112, DOI 10.1109/63.223961